eqptPowerBatDefenseMode

1.3.6.1.4.1.637.61.1.23.18.1.11

Description

The battery defense modes offers the operator the possibility to select the preferred power defense mode in case the system falls back to the battery mode. The power defense mode is a way to optimize the power consumption. In R5001 two options are possible. In later releases additional defense modes will be introduced…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.637.61.1.23.18.1 (eqptPowerEntry)
Node code
11
Node name
eqptPowerBatDefenseMode
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.637.61.1.23.18.1.11
URN notation
urn:oid:1.3.6.1.4.1.637.61.1.23.18.1.11
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 637 61 1 23 18 1 11}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) alcatel(637) asd(61) asam(1) asamEquipmentMIB(23) eqptPowerTable(18) eqptPowerEntry(1) eqptPowerBatDefenseMode(11)}
OID-IRI notation
  • /1/3/6/1/4/1/637/61/1/23/18/1/11
  • /ISO/Identified-Organization/6/1/4/1/637/61/1/23/18/1/11
  • /ISO/3/6/1/4/1/637/61/1/23/18/1/11
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/alcatel/61/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/identified-organization/dod/internet/private/enterprise/alcatel/asd/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/identified-organization/dod/internet/private/enterprises/alcatel/61/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/identified-organization/dod/internet/private/enterprises/alcatel/asd/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/alcatel/61/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/alcatel/asd/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/identified-organization/dod/internet/private/vendor-objects/alcatel/61/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/identified-organization/dod/internet/private/vendor-objects/alcatel/asd/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/org/dod/internet/private/enterprise/alcatel/61/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/org/dod/internet/private/enterprise/alcatel/asd/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/org/dod/internet/private/enterprises/alcatel/61/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/org/dod/internet/private/enterprises/alcatel/asd/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/org/dod/internet/private/ldap-enterprise/alcatel/61/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/org/dod/internet/private/ldap-enterprise/alcatel/asd/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/org/dod/internet/private/vendor-objects/alcatel/61/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • /iso/org/dod/internet/private/vendor-objects/alcatel/asd/asam/asamEquipmentMIB/eqptPowerTable/eqptPowerEntry/eqptPowerBatDefenseMode
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Enumerated values

ValueName
0no-defense
1voice-priority

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: eqptPowerId.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.637.61.1.23.18.1.11

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

eqptPowerBatDefenseMode OBJECT-TYPE
      SYNTAX INTEGER
         {
          no-defense (0),
          voice-priority (1)
         }
      ACCESS read-write
      STATUS mandatory
      DESCRIPTION
         "
          The battery defense modes offers the operator the possibility to
          select the preferred power defense mode in case the system falls
          back to the battery mode. The power defense mode is a way to
          optimize the power consumption. In R5001 two options are possible.
          In later releases additional defense modes will be introduced.
          - no battery defense. In this mode the system will run normally,
            offering regular service until the battery runs out and the
            regular hw defenses are started (Dying Gasp)
          - voice priority. In this mode when the system falls back to the
            battery the regular service will be maintained until the battery
            drains until 90% and will then give priority to the voice LT's by
            powering down the DSL LT's. Voice service will be maintained until
            the battery runs out and the regular hw defenses are started (Dying
            Gasp).
          This configuration only possible for planned powermanagement devices,
          in this case a planned RANI-B or RPNI-B.

          ALCATEL NOTE:
          SUPPORT: YES   INSRVMOD: NA     RANGE: See above
          PERSIST: YES   DEFVALUE: 0      UNITS: - "
      ::= { eqptPowerEntry 11}

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The battery defense modes offers the operator the possibility to select the preferred power defense mode in case the system falls back to the battery mode. The power defense mode is a way to optimize the power consumption. In R5001 two options are possible. In later releases additional defense modes will be introduced. - no battery defense. In this mode the system will run normally, offering regular service until the battery runs out and the regular hw defenses are started (Dying Gasp) - voice priority. In this mode when the system falls back to the battery the regular service will be maintained until the battery drains until 90% and will then give priority to the voice LT's by powering down the DSL LT's. Voice service will be maintained until the battery runs out and the regular hw defenses are started (Dying Gasp). This configuration only possible for planned powermanagement devices, in this case a planned RANI-B or RPNI-B. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 0 UNITS: -

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Nokia networking MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Nokia networking MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

eqptPowerBatDefenseMode · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Nokia networking MIB copies (LibreNMS/Observium Community)2 sources

Status in source: mandatory.

Names: eqptPowerBatDefenseMode

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eqptPowerBatDefenseMode",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "no-defense",
    "(",
    "0",
    ")",
    ",",
    "voice-priority",
    "(",
    "1",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\" The battery defense modes offers the operator the possibility to select the preferred power defense mode in case the system falls back to the battery mode. The power defense mode is a way to optimize the power consumption. In R5001 two options are possible. In later releases additional defense modes will be introduced. - no battery defense. In this mode the system will run normally, offering regular service until the battery runs out and the regular hw defenses are started (Dying Gasp) - voice priority. In this mode when the system falls back to the battery the regular service will be maintained until the battery drains until 90% and will then give priority to the voice LT's by powering down the DSL LT's. Voice service will be maintained until the battery runs out and the regular hw defenses are started (Dying Gasp). This configuration only possible for planned powermanagement devices, in this case a planned RANI-B or RPNI-B. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 0 UNITS: - \"",
    "::=",
    "{",
    "eqptPowerEntry",
    "11",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "no-defense",
            0
          ],
          [
            "voice-priority",
            1
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The battery defense modes offers the operator the possibility to select the preferred power defense mode in case the system falls back to the battery mode. The power defense mode is a way to optimize the power consumption. In R5001 two options are possible. In later releases additional defense modes will be introduced. - no battery defense. In this mode the system will run normally, offering regular service until the battery runs out and the regular hw defenses are started (Dying Gasp) - voice priority. In this mode when the system falls back to the battery the regular service will be maintained until the battery drains until 90% and will then give priority to the voice LT's by powering down the DSL LT's. Voice service will be maintained until the battery runs out and the regular hw defenses are started (Dying Gasp). This configuration only possible for planned powermanagement devices, in this case a planned RANI-B or RPNI-B. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 0 UNITS: -"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.637)

Douglas E. Johnson

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.637)

Jean Rojnic

Siblings (24)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.637.61.1.23.18.1.1 eqptPowerId00
1.3.6.1.4.1.637.61.1.23.18.1.2 eqptPowerAdminMode00
1.3.6.1.4.1.637.61.1.23.18.1.3 eqptPowerOperMode00
1.3.6.1.4.1.637.61.1.23.18.1.4 eqptPowerBatType00
1.3.6.1.4.1.637.61.1.23.18.1.5 eqptPowerBatStartCapacity00
1.3.6.1.4.1.637.61.1.23.18.1.6 eqptPowerBatPlannedLifetime00
1.3.6.1.4.1.637.61.1.23.18.1.7 eqptPowerBatState00
1.3.6.1.4.1.637.61.1.23.18.1.8 eqptPowerBatFailure00
1.3.6.1.4.1.637.61.1.23.18.1.9 eqptPowerBatTemperature00
1.3.6.1.4.1.637.61.1.23.18.1.10 eqptPowerBatActualCapacity00
1.3.6.1.4.1.637.61.1.23.18.1.12 eqptPowerBatDefenseThreshold00
1.3.6.1.4.1.637.61.1.23.18.1.13 eqptPowerACState00
1.3.6.1.4.1.637.61.1.23.18.1.14 eqptPowerACFailure00
1.3.6.1.4.1.637.61.1.23.18.1.15 eqptPowerNDCaState00
1.3.6.1.4.1.637.61.1.23.18.1.16 eqptPowerNDCaFailure00
1.3.6.1.4.1.637.61.1.23.18.1.17 eqptPowerNDCbState00
1.3.6.1.4.1.637.61.1.23.18.1.18 eqptPowerNDCbFailure00
1.3.6.1.4.1.637.61.1.23.18.1.19 eqptPowerLDCaState00
1.3.6.1.4.1.637.61.1.23.18.1.20 eqptPowerLDCaFailure00
1.3.6.1.4.1.637.61.1.23.18.1.21 eqptPowerLDCbState00
1.3.6.1.4.1.637.61.1.23.18.1.22 eqptPowerLDCbFailure00
1.3.6.1.4.1.637.61.1.23.18.1.23 eqptPowerInVoltage00
1.3.6.1.4.1.637.61.1.23.18.1.24 eqptPowerInCurrent00
1.3.6.1.4.1.637.61.1.23.18.1.25 eqptPowerInConsumedPower00