Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"chasEntPhysOperStatus",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"up",
"(",
"1",
")",
",",
"down",
"(",
"2",
")",
",",
"testing",
"(",
"3",
")",
",",
"unknown",
"(",
"4",
")",
",",
"secondary",
"(",
"5",
")",
",",
"notPresent",
"(",
"6",
")",
",",
"unpowered",
"(",
"7",
")",
",",
"master",
"(",
"8",
")",
",",
"idle",
"(",
"9",
")",
",",
"pwrsave",
"(",
"10",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value : up <=> powered up Control Module possible value : notPresent <=> CM not present up <=> CM up and running down <=> CM down and powered secondary <=> CM in secondary mode and running NI status possible value : notPresent <=> NI not present up <=> NI up and running down <=> NI down and powered unpowered <=> NI unpowered because there is not enough power in the system (chasEntPhysAdminStatus = powerOn) or because the NI has to be OFF (chasEntPhysAdminStatus = powerOff). This operational status has not full meaning without chasEntPhysAdminStatus Fabric status possible value : master <=> up and acting as master up <=> up and acting as slave secondary <=> secondary mode for redundancy Daughter board status possible value : notPresent <=> DB not present up <=> DB up and running down <=> DB down and powered Power supply status possible value : up <=> PS up down <=> PS administratively down unpowered <=> PS not plugged in pwrsave <=> chassis in powersave mode, supply turned off Fan Tray status possible value : up <=> powered up down <=> powered down fault <=> fault detected\"",
"::=",
"{",
"chasEntPhysicalEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"up",
1
],
[
"down",
2
],
[
"testing",
3
],
[
"unknown",
4
],
[
"secondary",
5
],
[
"notPresent",
6
],
[
"unpowered",
7
],
[
"master",
8
],
[
"idle",
9
],
[
"pwrsave",
10
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value : up <=> powered up Control Module possible value : notPresent <=> CM not present up <=> CM up and running down <=> CM down and powered secondary <=> CM in secondary mode and running NI status possible value : notPresent <=> NI not present up <=> NI up and running down <=> NI down and powered unpowered <=> NI unpowered because there is not enough power in the system (chasEntPhysAdminStatus = powerOn) or because the NI has to be OFF (chasEntPhysAdminStatus = powerOff). This operational status has not full meaning without chasEntPhysAdminStatus Fabric status possible value : master <=> up and acting as master up <=> up and acting as slave secondary <=> secondary mode for redundancy Daughter board status possible value : notPresent <=> DB not present up <=> DB up and running down <=> DB down and powered Power supply status possible value : up <=> PS up down <=> PS administratively down unpowered <=> PS not plugged in pwrsave <=> chassis in powersave mode, supply turned off Fan Tray status possible value : up <=> powered up down <=> powered down fault <=> fault detected"
],
null,
null,
null,
null
]
}