OID reference

chasEntPhysOperStatus

1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.2

Description

All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value : up <=> powered up Control Module possible value : notPresent <=> CM not present up <=> CM up and running down <=> CM down and powered secondary <=> CM in secondary mode and running NI status possible v…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1 (chasEntPhysicalEntry)
Node code
2
Node name
chasEntPhysOperStatus
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.2
URN notation
urn:oid:1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 6486 801 1 1 1 1 1 1 1 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Physical(1) alcatelIND1ChassisPhysMIBObjects(1) chasEntPhysicalTable(1) chasEntPhysicalEntry(1) chasEntPhysOperStatus(2)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/6486/801/1/1/1/1/1/1/1/2
  • /ISO/Identified-Organization/6/1/4/1/6486/801/1/1/1/1/1/1/1/2
  • /ISO/3/6/1/4/1/6486/801/1/1/1/1/1/1/1/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/identified-organization/dod/internet/private/enterprise/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/identified-organization/dod/internet/private/enterprises/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/identified-organization/dod/internet/private/enterprises/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/org/dod/internet/private/enterprise/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/org/dod/internet/private/enterprise/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/org/dod/internet/private/enterprises/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/org/dod/internet/private/enterprises/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/org/dod/internet/private/ldap-enterprise/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/org/dod/internet/private/ldap-enterprise/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/org/dod/internet/private/vendor-objects/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • /iso/org/dod/internet/private/vendor-objects/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Physical/alcatelIND1ChassisPhysMIBObjects/chasEntPhysicalTable/chasEntPhysicalEntry/chasEntPhysOperStatus
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Enumerated values

ValueName
1up
2down
3testing
4unknown
5secondary
6notPresent
7unpowered
8master
9idle
10pwrsave

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: entPhysicalIndex.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.2

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

chasEntPhysOperStatus OBJECT-TYPE
        SYNTAX INTEGER
        {
                up(1),
                down(2),
                testing(3),
                unknown(4),
                secondary(5),
                notPresent(6),
                unpowered(7),
                master(8),
                idle(9),
                pwrsave(10)
        }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
        "All modules (even empty slots) are in unknown state when the chassis
        first powers up.

        Chassis status possible value :
                up <=> powered up

        Control Module possible value :
                notPresent <=> CM not present
                up <=> CM up and running
                down <=> CM down and powered
                secondary <=> CM in secondary mode and running

        NI status possible value :
                notPresent <=> NI not present
                up <=> NI up and running
                down <=> NI down and powered
                unpowered <=> NI unpowered because there is not enough power in the system
                              (chasEntPhysAdminStatus = powerOn) or because the NI has to be OFF
                              (chasEntPhysAdminStatus = powerOff). This operational status has
                  not full meaning without chasEntPhysAdminStatus

        Fabric status possible value :
                master <=> up and acting as master
                up <=> up and acting as slave
                secondary <=> secondary mode for redundancy

        Daughter board status possible value :
                notPresent <=> DB not present
                up <=> DB up and running
                down <=> DB down and powered

        Power supply status possible value :
                up <=> PS up
                down <=> PS administratively down
                unpowered <=> PS not plugged in
                pwrsave <=> chassis in powersave mode, supply turned off

        Fan Tray status possible value :
                up <=> powered up
                down <=> powered down
                fault <=> fault detected"
::= { chasEntPhysicalEntry 2 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value : up <=> powered up Control Module possible value : notPresent <=> CM not present up <=> CM up and running down <=> CM down and powered secondary <=> CM in secondary mode and running NI status possible value : notPresent <=> NI not present up <=> NI up and running down <=> NI down and powered unpowered <=> NI unpowered because there is not enough power in the system (chasEntPhysAdminStatus = powerOn) or because the NI has to be OFF (chasEntPhysAdminStatus = powerOff). This operational status has not full meaning without chasEntPhysAdminStatus Fabric status possible value : master <=> up and acting as master up <=> up and acting as slave secondary <=> secondary mode for redundancy Daughter board status possible value : notPresent <=> DB not present up <=> DB up and running down <=> DB down and powered Power supply status possible value : up <=> PS up down <=> PS administratively down unpowered <=> PS not plugged in pwrsave <=> chassis in powersave mode, supply turned off Fan Tray status possible value : up <=> powered up down <=> powered down fault <=> fault detected

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Alcatel-Lucent Enterprise MIB copies (LibreNMS)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Alcatel-Lucent Enterprise MIB copies (LibreNMS)1 record · 3 sources

Description 1

chasEntPhysOperStatus · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Alcatel-Lucent Enterprise MIB copies (LibreNMS)3 sources

Status in source: current.

Names: chasEntPhysOperStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "chasEntPhysOperStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "up",
    "(",
    "1",
    ")",
    ",",
    "down",
    "(",
    "2",
    ")",
    ",",
    "testing",
    "(",
    "3",
    ")",
    ",",
    "unknown",
    "(",
    "4",
    ")",
    ",",
    "secondary",
    "(",
    "5",
    ")",
    ",",
    "notPresent",
    "(",
    "6",
    ")",
    ",",
    "unpowered",
    "(",
    "7",
    ")",
    ",",
    "master",
    "(",
    "8",
    ")",
    ",",
    "idle",
    "(",
    "9",
    ")",
    ",",
    "pwrsave",
    "(",
    "10",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value : up <=> powered up Control Module possible value : notPresent <=> CM not present up <=> CM up and running down <=> CM down and powered secondary <=> CM in secondary mode and running NI status possible value : notPresent <=> NI not present up <=> NI up and running down <=> NI down and powered unpowered <=> NI unpowered because there is not enough power in the system (chasEntPhysAdminStatus = powerOn) or because the NI has to be OFF (chasEntPhysAdminStatus = powerOff). This operational status has not full meaning without chasEntPhysAdminStatus Fabric status possible value : master <=> up and acting as master up <=> up and acting as slave secondary <=> secondary mode for redundancy Daughter board status possible value : notPresent <=> DB not present up <=> DB up and running down <=> DB down and powered Power supply status possible value : up <=> PS up down <=> PS administratively down unpowered <=> PS not plugged in pwrsave <=> chassis in powersave mode, supply turned off Fan Tray status possible value : up <=> powered up down <=> powered down fault <=> fault detected\"",
    "::=",
    "{",
    "chasEntPhysicalEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "up",
            1
          ],
          [
            "down",
            2
          ],
          [
            "testing",
            3
          ],
          [
            "unknown",
            4
          ],
          [
            "secondary",
            5
          ],
          [
            "notPresent",
            6
          ],
          [
            "unpowered",
            7
          ],
          [
            "master",
            8
          ],
          [
            "idle",
            9
          ],
          [
            "pwrsave",
            10
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value : up <=> powered up Control Module possible value : notPresent <=> CM not present up <=> CM up and running down <=> CM down and powered secondary <=> CM in secondary mode and running NI status possible value : notPresent <=> NI not present up <=> NI up and running down <=> NI down and powered unpowered <=> NI unpowered because there is not enough power in the system (chasEntPhysAdminStatus = powerOn) or because the NI has to be OFF (chasEntPhysAdminStatus = powerOff). This operational status has not full meaning without chasEntPhysAdminStatus Fabric status possible value : master <=> up and acting as master up <=> up and acting as slave secondary <=> secondary mode for redundancy Daughter board status possible value : notPresent <=> DB not present up <=> DB up and running down <=> DB down and powered Power supply status possible value : up <=> PS up down <=> PS administratively down unpowered <=> PS not plugged in pwrsave <=> chassis in powersave mode, supply turned off Fan Tray status possible value : up <=> powered up down <=> powered down fault <=> fault detected"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.6486)

Dalton David R.

Siblings (39)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.1 chasEntPhysAdminStatus00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.3 chasEntPhysPower00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.4 chasEntPhysModuleType00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.5 chasEntPhysPartNumber00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.6 chasEntPhysLedStatusOk100
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.7 chasEntPhysLedStatusOk200
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.8 chasEntPhysLedStatusPrimaryCMM00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.9 chasEntPhysLedStatusSecondaryCMM00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.10 chasEntPhysLedStatusTemperature00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.11 chasEntPhysLedStatusFan00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.12 chasEntPhysLedStatusBackupPS00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.13 chasEntPhysLedStatusInternalPS00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.14 chasEntPhysLedStatusControl00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.15 chasEntPhysLedStatusFabric00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.16 chasEntPhysLedStatusPS00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.17 chasEntPhysAsic1Rev00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.18 chasEntPhysAsic2Rev00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.19 chasEntPhysAsic3Rev00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.20 chasEntPhysAsic4Rev00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.21 chasEntPhysAsic5Rev00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.22 chasEntPhysAsic6Rev00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.23 chasEntPhysCpldRev00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.24 chasEntPhysDaughterFpga1Rev00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.25 chasEntPhysDaughterFpga2Rev00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.26 chasEntPhysNiNum00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.27 chasEntPhysGbicNum00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.28 chasEntPhysWaveLen00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.29 chasEntPhysUbootRev00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.30 chasEntPhysUbootMinibootRev00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.31 chasEntPhysMacAddress00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.32 chasEntPhysCpuModel00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.33 chasEntPhysAirflow00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.34 chasEntPhysPowerUsed00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.35 chasEntPhysPowerType00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.36 chasEntPowerSupplyName00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.37 chasEntPowerSupplyType00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.38 chasEntPowerSupplyInputType00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.39 chasEntPowerSupplyWattage00
1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.40 chasEntPowerSupplyVoltage00