chasPowerSupplyRedundancy

1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.24

Description

This object indicates the state of power supply redundancy mode. When on(1), N+1 mode redundancy is enabled(default mode). In this mode the system controls the power supplies to maintain efficient use of the power supplies, with 1 extra power supply in case of a power supply failure. Unneeded power supplies are powere…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1 (chasChassisEntry)
Node code
24
Node name
chasPowerSupplyRedundancy
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.24
URN notation
urn:oid:1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.24
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 6486 801 1 1 1 3 1 1 3 1 24}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) alcatel(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ale(6486) alcatelIND1BaseMIB(801) alcatelIND1Management(1) managementIND1Hardware(1) hardwareIND1Entities(1) hardentIND1Chassis(3) alcatelIND1ChassisMIB(1) alcatelIND1ChassisMIBObjects(1) chasChassisTable(3) chasChassisEntry(1) chasPowerSupplyRedundancy(24)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/6486/801/1/1/1/3/1/1/3/1/24
  • /ISO/Identified-Organization/6/1/4/1/6486/801/1/1/1/3/1/1/3/1/24
  • /ISO/3/6/1/4/1/6486/801/1/1/1/3/1/1/3/1/24
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/identified-organization/dod/internet/private/enterprise/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/identified-organization/dod/internet/private/enterprises/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/identified-organization/dod/internet/private/enterprises/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/identified-organization/dod/internet/private/vendor-objects/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/identified-organization/dod/internet/private/vendor-objects/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/org/dod/internet/private/enterprise/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/org/dod/internet/private/enterprise/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/org/dod/internet/private/enterprises/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/org/dod/internet/private/enterprises/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/org/dod/internet/private/ldap-enterprise/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/org/dod/internet/private/ldap-enterprise/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/org/dod/internet/private/vendor-objects/alcatel/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • /iso/org/dod/internet/private/vendor-objects/ale/alcatelIND1BaseMIB/alcatelIND1Management/managementIND1Hardware/hardwareIND1Entities/hardentIND1Chassis/alcatelIND1ChassisMIB/alcatelIND1ChassisMIBObjects/chasChassisTable/chasChassisEntry/chasPowerSupplyRedundancy
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
on

Enumerated values

ValueName
1on
2off

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: entPhysicalIndex.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.24

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

chasPowerSupplyRedundancy       OBJECT-TYPE
    SYNTAX INTEGER
    {
       on(1),
       off(2)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object indicates the state of power supply redundancy mode.
         When on(1), N+1 mode redundancy is enabled(default mode). In
         this mode the system controls the power supplies to maintain
         efficient use of the power supplies, with 1 extra power supply
         in case of a power supply failure. Unneeded power supplies are
         powered off. It can be set to off(2) to disable redundancy mode.
         In this mode all power supplies are powered on.
         This object is applicable only to OS10K devices."
    DEFVAL   { on }
::= { chasChassisEntry 24 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This object indicates the state of power supply redundancy mode. When on(1), N+1 mode redundancy is enabled(default mode). In this mode the system controls the power supplies to maintain efficient use of the power supplies, with 1 extra power supply in case of a power supply failure. Unneeded power supplies are powered off. It can be set to off(2) to disable redundancy mode. In this mode all power supplies are powered on. This object is applicable only to OS10K devices.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Alcatel-Lucent Enterprise MIB copies (LibreNMS)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Alcatel-Lucent Enterprise MIB copies (LibreNMS)1 record · 3 sources

Description 1

chasPowerSupplyRedundancy · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Alcatel-Lucent Enterprise MIB copies (LibreNMS)3 sources

Status in source: current.

Names: chasPowerSupplyRedundancy

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "chasPowerSupplyRedundancy",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "on",
    "(",
    "1",
    ")",
    ",",
    "off",
    "(",
    "2",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This object indicates the state of power supply redundancy mode. When on(1), N+1 mode redundancy is enabled(default mode). In this mode the system controls the power supplies to maintain efficient use of the power supplies, with 1 extra power supply in case of a power supply failure. Unneeded power supplies are powered off. It can be set to off(2) to disable redundancy mode. In this mode all power supplies are powered on. This object is applicable only to OS10K devices.\"",
    "DEFVAL",
    "{",
    "on",
    "}",
    "::=",
    "{",
    "chasChassisEntry",
    "24",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "on",
            1
          ],
          [
            "off",
            2
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This object indicates the state of power supply redundancy mode. When on(1), N+1 mode redundancy is enabled(default mode). In this mode the system controls the power supplies to maintain efficient use of the power supplies, with 1 extra power supply in case of a power supply failure. Unneeded power supplies are powered off. It can be set to off(2) to disable redundancy mode. In this mode all power supplies are powered on. This object is applicable only to OS10K devices."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "on"
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.6486)

Dalton David R.

Siblings (24)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.1 chasFreeSlots00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.2 chasPowerLeft00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.3 chasNumberOfResets00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.4 chasTempRange00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.5 chasTempThreshold00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.6 chasDangerTempThreshold00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.7 chasPrimaryPhysicalIndex00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.8 chasCPMAHardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.9 chasCFMAHardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.10 chasCPMBHardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.11 chasCFMBHardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.12 chasCFMCHardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.13 chasCFMDHardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.14 chasFTAHardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.15 chasFTBHardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.16 chasNI1HardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.17 chasNI2HardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.18 chasNI3HardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.19 chasNI4HardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.20 chasNI5HardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.21 chasNI6HardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.22 chasNI7HardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.23 chasNI8HardwareBoardTemp00
1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.25 chasPowerSupplyRedundancyReserve00