Compliance statement for Chassis Supervision.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Alcatel-Lucent Enterprise MIB copies (LibreNMS)
OID reference
1.3.6.1.4.1.6486.801.1.1.1.3.1.2.2.1
Compliance statement for Chassis Supervision.
Identification
{1 3 6 1 4 1 6486 801 1 1 1 3 1 2 2 1}
The displayed source records contain one distinct definition. Compare its source records.
alcatelIND1ChassisMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for Chassis Supervision."
MODULE
MANDATORY-GROUPS
{
chasControlModuleGroup ,
chasControlRedundantGroup ,
chasChassisGroup ,
chasControlReloadStatusGroup ,
chasGlobalControlGroup ,
chassisNotificationGroup ,
alaChasEntPhysFanGroup ,
alaChasNotificationObjectGroup ,
chassisSupervisionRfsCommandsGroup ,
chasSupervisionCmmCertifiedEntryGroup,
chasSupervisionFlashMemEntryGroup ,
chasSupervisionRfsDfEntryGroup ,
chasSupervisionRfsLsEntryGroup,
alaChasBpsFwGroup,
alaChasBpsConnectorPriorityGroup,
alaChasBpsModeGroup,
alaChasBpsPowerSupplyGroup,
alaChasBpsTotalPowerAllocGroup
}
::= { alcatelIND1ChassisMIBCompliances 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Compliance statement for Chassis Supervision.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Alcatel-Lucent Enterprise MIB copies (LibreNMS)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: alcatelIND1ChassisMIBCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"alcatelIND1ChassisMIBCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"Compliance statement for Chassis Supervision.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"chasControlModuleGroup",
",",
"chasControlRedundantGroup",
",",
"chasChassisGroup",
",",
"chasControlReloadStatusGroup",
",",
"chasGlobalControlGroup",
",",
"chassisNotificationGroup",
",",
"alaChasEntPhysFanGroup",
",",
"alaChasNotificationObjectGroup",
",",
"chassisSupervisionRfsCommandsGroup",
",",
"chasSupervisionCmmCertifiedEntryGroup",
",",
"chasSupervisionFlashMemEntryGroup",
",",
"chasSupervisionRfsDfEntryGroup",
",",
"chasSupervisionRfsLsEntryGroup",
",",
"alaChasBpsFwGroup",
",",
"alaChasBpsConnectorPriorityGroup",
",",
"alaChasBpsModeGroup",
",",
"alaChasBpsPowerSupplyGroup",
",",
"alaChasBpsTotalPowerAllocGroup",
"}",
"::=",
"{",
"alcatelIND1ChassisMIBCompliances",
"1",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"Compliance statement for Chassis Supervision."
],
null,
[
"ComplianceModules",
[
[
null,
[
"chasControlModuleGroup",
"chasControlRedundantGroup",
"chasChassisGroup",
"chasControlReloadStatusGroup",
"chasGlobalControlGroup",
"chassisNotificationGroup",
"alaChasEntPhysFanGroup",
"alaChasNotificationObjectGroup",
"chassisSupervisionRfsCommandsGroup",
"chasSupervisionCmmCertifiedEntryGroup",
"chasSupervisionFlashMemEntryGroup",
"chasSupervisionRfsDfEntryGroup",
"chasSupervisionRfsLsEntryGroup",
"alaChasBpsFwGroup",
"alaChasBpsConnectorPriorityGroup",
"alaChasBpsModeGroup",
"alaChasBpsPowerSupplyGroup",
"alaChasBpsTotalPowerAllocGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive. Alcatel-Lucent Enterprise support.
Module: ALCATEL-IND1-CHASSIS-MIB
See published definition above
{'SNMPv2-TC': ['MacAddress', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'entPhysicalIndex'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'OBJECT-IDENTITY', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'IpAddress', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'ALCATEL-IND1-BASE': ['hardentIND1Physical', 'hardentIND1Chassis'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Vendor MIB copy from the LibreNMS archive.
Module: ALCATEL-IND1-CHASSIS-MIB
{'SNMPv2-TC': ['MacAddress', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'entPhysicalIndex'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'OBJECT-IDENTITY', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'IpAddress', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'ALCATEL-IND1-BASE': ['hardentIND1Physical', 'hardentIND1Chassis'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Vendor MIB copy from the Observium Community archive.
Module: ALCATEL-ENT1-CHASSIS-MIB
{'SNMPv2-TC': ['MacAddress', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'entPhysicalIndex'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'OBJECT-IDENTITY', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'IpAddress', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'ALCATEL-ENT1-BASE': ['hardentIND1Physical', 'hardentIND1Chassis'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration