OID reference

sbiPersistStatus

1.3.6.1.4.1.6527.3.1.2.1.5.2

Description

The value of sbiPersistStatus indicates the state of the rebuild of the SNMP persistent index database upon reboot of the system. persistOK (1) - The persistent index database was successfully created. Persistent SNMP managed objects were recreated with the same SNMP indexes they had prior to the system reboot. noPers…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.6527.3.1.2.1.5 (sysBootInfo)
Node code
2
Node name
sbiPersistStatus
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.6527.3.1.2.1.5.2
URN notation
urn:oid:1.3.6.1.4.1.6527.3.1.2.1.5.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 6527 3 1 2 1 5 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxSysObjs(1) sysBootInfo(5) sbiPersistStatus(2)}
OID-IRI notation
  • /1/3/6/1/4/1/6527/3/1/2/1/5/2
  • /ISO/Identified-Organization/6/1/4/1/6527/3/1/2/1/5/2
  • /ISO/3/6/1/4/1/6527/3/1/2/1/5/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/identified-organization/dod/internet/private/enterprises/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/org/dod/internet/private/enterprise/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/org/dod/internet/private/enterprises/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/org/dod/internet/private/ldap-enterprise/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/org/dod/internet/private/vendor-objects/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprise/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprises/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/iso-organization/dod/internet/private/enterprise/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/iso-organization/dod/internet/private/enterprises/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus
  • /iso/iso-organization/dod/internet/private/vendor-objects/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxSysObjs/sysBootInfo/sbiPersistStatus

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Enumerated values

ValueName
1persistOK
2noPersistFile
3persistMismatch
4persistIndexFailure
5persistDisabled
6persistInvalid
7persistBoot
8persistInit
9persistInProgress

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.6527.3.1.2.1.5.2.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

sbiPersistStatus · current

sbiPersistStatus                 OBJECT-TYPE
    SYNTAX      INTEGER {
        persistOK           (1),
        noPersistFile       (2),
        persistMismatch     (3),
        persistIndexFailure (4),
        persistDisabled     (5),
        persistInvalid      (6),
        persistBoot         (7),
        persistInit         (8),
        persistInProgress   (9)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of sbiPersistStatus indicates the state of the
         rebuild of the SNMP persistent index database upon reboot of the
         system.
            persistOK (1) - The persistent index database was
                successfully created.  Persistent SNMP managed
                objects were recreated with the same SNMP
                indexes they had prior to the system reboot.
            noPersistFile (2) - There was no persistent index file with
                the same pathname as the configuration file.
            persistMismatch (3) -The headers in the persistent index
                file and the configuration file with the same name
                do not match.
            persistIndexFailure (4) - An error occurred while creating
                the persistent index database.
            persistDisabled (5) - The system was administratively
                reconfigured without maintaining persistent SNMP index
                values because sbiPersistIndex has a value of 'false'.
            persistInvalid (6) - Persistent index database was not
                                 initialized.
            persistBoot(7) - The persistent index database was in the
                             pre-initial bootup state.
            persistInit(8) - The persistent index database is initializing.
            persistInProgress(9) - The initial bootup file is loading, using the
                                   persist index database. Once complete, the
                                   persist state will go to 'persistOk (1)' if
                                   successful.

         If sbiConfigStatus has a value of 'configOK' and
         sbiPersistStatus has any value other than 'persistOK', the
         system was reconfigured without maintaining persistent SNMP index
         values.  Unless sbiPersistIndex has a value of 'false',
         sbiSnmpdOperStatus returns 'disabled' and the SNMP daemon will not
         receive SNMP requests until sbiSnmpdAdminStatus variable has
         been set to 'inService'."
    ::= { sysBootInfo 2 }

sbiPersistStatus · current

sbiPersistStatus                 OBJECT-TYPE
    SYNTAX      INTEGER {
        persistOK           (1),
        noPersistFile       (2),
        persistMismatch     (3),
        persistIndexFailure (4),
        persistDisabled     (5),
        persistInvalid      (6),
        persistBoot         (7),
        persistInit         (8),
        persistInProgress   (9)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of sbiPersistStatus indicates the state of the
         rebuild of the SNMP persistent index database upon reboot of the
         system.
            persistOK (1) - The persistent index database was
                successfully created.  Persistent SNMP managed
                objects were recreated with the same SNMP
                indexes they had prior to the system reboot.
            noPersistFile (2) - There was no persistent index file with
                the same pathname as the configuration file.
            persistMismatch (3) -The headers in the persistent index
                file and the configuration file with the same name
                do not match.
            persistIndexFailure (4) - An error occurred while creating
                the persistent index database.
            persistDisabled (5) - The system was administratively
                reconfigured without maintaining persistent SNMP index
                values because sbiPersistIndex has a value of 'false'.
            persistInvalid (6) - Persistent index database was not
                                 initialized.
            persistBoot(7) - The persistent index database was in the
                             pre-initial bootup state.
            persistInit(8) - The persistent index database is initializing.
            persistInProgress(9) - The initial bootup file is loading, using the
                                   persist index database. Once complete, the
                                   persist state will go to 'persistOK (1)' if
                                   successful.

         If sbiConfigStatus has a value of 'configOK' and
         sbiPersistStatus has any value other than 'persistOK', the
         system was reconfigured without maintaining persistent SNMP index
         values.  Unless sbiPersistIndex has a value of 'false',
         sbiSnmpdOperStatus returns 'disabled' and the SNMP daemon will not
         receive SNMP requests until sbiSnmpdAdminStatus variable has
         been set to 'inService'."
    ::= { sysBootInfo 2 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

The value of sbiPersistStatus indicates the state of the rebuild of the SNMP persistent index database upon reboot of the system. persistOK (1) - The persistent index database was successfully created. Persistent SNMP managed objects were recreated with the same SNMP indexes they had prior to the system reboot. noPersistFile (2) - There was no persistent index file with the same pathname as the configuration file. persistMismatch (3) -The headers in the persistent index file and the configuration file with the same name do not match. persistIndexFailure (4) - An error occurred while creating the persistent index database. persistDisabled (5) - The system was administratively reconfigured without maintaining persistent SNMP index values because sbiPersistIndex has a value of 'false'. persistInvalid (6) - Persistent index database was not initialized. persistBoot(7) - The persistent index database was in the pre-initial bootup state. persistInit(8) - The persistent index database is initializing. persistInProgress(9) - The initial bootup file is loading, using the persist index database. Once complete, the persist state will go to 'persistOk (1)' if successful. If sbiConfigStatus has a value of 'configOK' and sbiPersistStatus has any value other than 'persistOK', the system was reconfigured without maintaining persistent SNMP index values. Unless sbiPersistIndex has a value of 'false', sbiSnmpdOperStatus returns 'disabled' and the SNMP daemon will not receive SNMP requests until sbiSnmpdAdminStatus variable has been set to 'inService'.

Sources for this description

Netdisco MIB archive copiesNokia networking MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

The value of sbiPersistStatus indicates the state of the rebuild of the SNMP persistent index database upon reboot of the system. persistOK (1) - The persistent index database was successfully created. Persistent SNMP managed objects were recreated with the same SNMP indexes they had prior to the system reboot. noPersistFile (2) - There was no persistent index file with the same pathname as the configuration file. persistMismatch (3) -The headers in the persistent index file and the configuration file with the same name do not match. persistIndexFailure (4) - An error occurred while creating the persistent index database. persistDisabled (5) - The system was administratively reconfigured without maintaining persistent SNMP index values because sbiPersistIndex has a value of 'false'. persistInvalid (6) - Persistent index database was not initialized. persistBoot(7) - The persistent index database was in the pre-initial bootup state. persistInit(8) - The persistent index database is initializing. persistInProgress(9) - The initial bootup file is loading, using the persist index database. Once complete, the persist state will go to 'persistOK (1)' if successful. If sbiConfigStatus has a value of 'configOK' and sbiPersistStatus has any value other than 'persistOK', the system was reconfigured without maintaining persistent SNMP index values. Unless sbiPersistIndex has a value of 'false', sbiSnmpdOperStatus returns 'disabled' and the SNMP daemon will not receive SNMP requests until sbiSnmpdAdminStatus variable has been set to 'inService'.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Nokia networking MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Netdisco MIB archive copies, Nokia networking MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

sbiPersistStatus · currentNetdisco MIB archive copies, Nokia networking MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: sbiPersistStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sbiPersistStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "persistOK",
    "(",
    "1",
    ")",
    ",",
    "noPersistFile",
    "(",
    "2",
    ")",
    ",",
    "persistMismatch",
    "(",
    "3",
    ")",
    ",",
    "persistIndexFailure",
    "(",
    "4",
    ")",
    ",",
    "persistDisabled",
    "(",
    "5",
    ")",
    ",",
    "persistInvalid",
    "(",
    "6",
    ")",
    ",",
    "persistBoot",
    "(",
    "7",
    ")",
    ",",
    "persistInit",
    "(",
    "8",
    ")",
    ",",
    "persistInProgress",
    "(",
    "9",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The value of sbiPersistStatus indicates the state of the rebuild of the SNMP persistent index database upon reboot of the system. persistOK (1) - The persistent index database was successfully created. Persistent SNMP managed objects were recreated with the same SNMP indexes they had prior to the system reboot. noPersistFile (2) - There was no persistent index file with the same pathname as the configuration file. persistMismatch (3) -The headers in the persistent index file and the configuration file with the same name do not match. persistIndexFailure (4) - An error occurred while creating the persistent index database. persistDisabled (5) - The system was administratively reconfigured without maintaining persistent SNMP index values because sbiPersistIndex has a value of 'false'. persistInvalid (6) - Persistent index database was not initialized. persistBoot(7) - The persistent index database was in the pre-initial bootup state. persistInit(8) - The persistent index database is initializing. persistInProgress(9) - The initial bootup file is loading, using the persist index database. Once complete, the persist state will go to 'persistOk (1)' if successful. If sbiConfigStatus has a value of 'configOK' and sbiPersistStatus has any value other than 'persistOK', the system was reconfigured without maintaining persistent SNMP index values. Unless sbiPersistIndex has a value of 'false', sbiSnmpdOperStatus returns 'disabled' and the SNMP daemon will not receive SNMP requests until sbiSnmpdAdminStatus variable has been set to 'inService'.\"",
    "::=",
    "{",
    "sysBootInfo",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "persistOK",
            1
          ],
          [
            "noPersistFile",
            2
          ],
          [
            "persistMismatch",
            3
          ],
          [
            "persistIndexFailure",
            4
          ],
          [
            "persistDisabled",
            5
          ],
          [
            "persistInvalid",
            6
          ],
          [
            "persistBoot",
            7
          ],
          [
            "persistInit",
            8
          ],
          [
            "persistInProgress",
            9
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The value of sbiPersistStatus indicates the state of the rebuild of the SNMP persistent index database upon reboot of the system. persistOK (1) - The persistent index database was successfully created. Persistent SNMP managed objects were recreated with the same SNMP indexes they had prior to the system reboot. noPersistFile (2) - There was no persistent index file with the same pathname as the configuration file. persistMismatch (3) -The headers in the persistent index file and the configuration file with the same name do not match. persistIndexFailure (4) - An error occurred while creating the persistent index database. persistDisabled (5) - The system was administratively reconfigured without maintaining persistent SNMP index values because sbiPersistIndex has a value of 'false'. persistInvalid (6) - Persistent index database was not initialized. persistBoot(7) - The persistent index database was in the pre-initial bootup state. persistInit(8) - The persistent index database is initializing. persistInProgress(9) - The initial bootup file is loading, using the persist index database. Once complete, the persist state will go to 'persistOk (1)' if successful. If sbiConfigStatus has a value of 'configOK' and sbiPersistStatus has any value other than 'persistOK', the system was reconfigured without maintaining persistent SNMP index values. Unless sbiPersistIndex has a value of 'false', sbiSnmpdOperStatus returns 'disabled' and the SNMP daemon will not receive SNMP requests until sbiSnmpdAdminStatus variable has been set to 'inService'."
    ],
    null,
    null,
    null,
    null
  ]
}
  • Nokia networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. Nokia support.

    Module: TIMETRA-SYSTEM-MIB

    See published definition above

    Module imports
    {'HCNUM-TC': ['CounterBasedGauge64'], 'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'MacAddress', 'RowPointer', 'RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['Counter32', 'Counter64', 'Gauge32', 'Integer32', 'IpAddress', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'TIMETRA-TC-MIB': ['IpAddressPrefixLength', 'TDSCPNameOrEmpty', 'TItemDescription', 'TLDisplayString', 'TLNamedItem', 'TLNamedItemOrEmpty', 'TNamedItem', 'TNamedItemOrEmpty', 'TTcpUdpPort', 'TmnxActionType', 'TmnxAdminState', 'TmnxAdminStateTruthValue', 'TmnxCliEngine', 'TmnxDisplayStringURL', 'TmnxEnabledDisabled', 'TmnxEnabledDisabledAdminState', 'TmnxLongDisplayString', 'TmnxOperState', 'TmnxScriptAuthType', 'TmnxServId', 'TmnxUuid', 'TmnxVRtrID', 'TmnxVRtrIDOrZero'], 'TIMETRA-LOG-MIB': ['tmnxEhsHEntryMinDelay', 'tmnxEhsHEntryMinDelayInterval', 'tmnxEhsHEntryScriptPlcyName', 'tmnxEhsHEntryScriptPlcyOwner', 'tmnxEhsHandlerDescription', 'tmnxLogExecRollbackOpIndex', 'tmnxLogExecRollbackOpType'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength', 'InetAddressType', 'InetPortNumber'], 'DISMAN-SCRIPT-MIB': ['smLaunchEntry', 'smLaunchError', 'smLaunchName', 'smLaunchOwner', 'smLaunchScriptName', 'smLaunchScriptOwner', 'smRunEntry', 'smRunIndex'], 'SNMP-COMMUNITY-MIB': ['snmpCommunityEntry'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRConfs', 'tmnxSRNotifyPrefix', 'tmnxSRObjs'], 'TIMETRA-CHASSIS-MIB': ['TmnxSlotNum', 'tmnxChassisBaseMacAddress', 'tmnxChassisIndex', 'tmnxChassisNotifyHwIndex', 'tmnxCpmCardNum', 'tmnxCpmCardSlotNum', 'tmnxFabricSlotNum', 'tmnxHwClass', 'tmnxHwID']}
    · Download TIMETRA-SYSTEM-MIB

    Related source files and packages:

  • Netdisco MIB archive copies · Publisher's source file: timetra-system-mib.mib

    Vendor MIB copy from the Netdisco archive.

    Module: TIMETRA-SYSTEM-MIB

    Same published definition (formatting differs; exact original is in the source file)

    Module imports
    {'HCNUM-TC': ['CounterBasedGauge64'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DateAndTime', 'DisplayString', 'MacAddress', 'RowStatus', 'TruthValue', 'RowPointer', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'IpAddress', 'Unsigned32', 'Counter64', 'Counter32', 'Gauge32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'TIMETRA-TC-MIB': ['TNamedItem', 'TNamedItemOrEmpty', 'TmnxAdminState', 'TmnxOperState', 'TmnxActionType', 'TTcpUdpPort', 'IpAddressPrefixLength', 'TmnxDisplayStringURL', 'TLDisplayString', 'TmnxVRtrID', 'TmnxVRtrIDOrZero', 'TmnxServId', 'TmnxUuid', 'TItemDescription', 'TmnxEnabledDisabled', 'TLNamedItem', 'TItemDescription', 'TmnxScriptAuthType'], 'TIMETRA-LOG-MIB': ['tmnxLogExecRollbackOpIndex', 'tmnxLogExecRollbackOpType', 'tmnxEhsHandlerDescription', 'tmnxEhsHEntryScriptPlcyOwner', 'tmnxEhsHEntryScriptPlcyName', 'tmnxEhsHEntryMinDelay', 'tmnxEhsHEntryMinDelayInterval'], 'INET-ADDRESS-MIB': ['InetAddressPrefixLength', 'InetAddressIPv6', 'InetPortNumber', 'InetAddressType', 'InetAddress'], 'DISMAN-SCRIPT-MIB': ['smLaunchEntry', 'smRunEntry', 'smLaunchOwner', 'smLaunchName', 'smRunIndex', 'smLaunchScriptOwner', 'smLaunchScriptName', 'smLaunchError'], 'SNMP-COMMUNITY-MIB': ['snmpCommunityEntry'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRObjs', 'tmnxSRConfs', 'tmnxSRNotifyPrefix'], 'TIMETRA-CHASSIS-MIB': ['tmnxChassisBaseMacAddress', 'tmnxChassisIndex', 'TmnxSlotNum', 'tmnxChassisNotifyHwIndex', 'tmnxHwID', 'tmnxHwClass', 'tmnxCpmCardSlotNum', 'tmnxCpmCardNum']}
    · Download timetra-system-mib.mib
Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Nokia networking MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 2

sbiPersistStatus · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Nokia networking MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: sbiPersistStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sbiPersistStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "persistOK",
    "(",
    "1",
    ")",
    ",",
    "noPersistFile",
    "(",
    "2",
    ")",
    ",",
    "persistMismatch",
    "(",
    "3",
    ")",
    ",",
    "persistIndexFailure",
    "(",
    "4",
    ")",
    ",",
    "persistDisabled",
    "(",
    "5",
    ")",
    ",",
    "persistInvalid",
    "(",
    "6",
    ")",
    ",",
    "persistBoot",
    "(",
    "7",
    ")",
    ",",
    "persistInit",
    "(",
    "8",
    ")",
    ",",
    "persistInProgress",
    "(",
    "9",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The value of sbiPersistStatus indicates the state of the rebuild of the SNMP persistent index database upon reboot of the system. persistOK (1) - The persistent index database was successfully created. Persistent SNMP managed objects were recreated with the same SNMP indexes they had prior to the system reboot. noPersistFile (2) - There was no persistent index file with the same pathname as the configuration file. persistMismatch (3) -The headers in the persistent index file and the configuration file with the same name do not match. persistIndexFailure (4) - An error occurred while creating the persistent index database. persistDisabled (5) - The system was administratively reconfigured without maintaining persistent SNMP index values because sbiPersistIndex has a value of 'false'. persistInvalid (6) - Persistent index database was not initialized. persistBoot(7) - The persistent index database was in the pre-initial bootup state. persistInit(8) - The persistent index database is initializing. persistInProgress(9) - The initial bootup file is loading, using the persist index database. Once complete, the persist state will go to 'persistOK (1)' if successful. If sbiConfigStatus has a value of 'configOK' and sbiPersistStatus has any value other than 'persistOK', the system was reconfigured without maintaining persistent SNMP index values. Unless sbiPersistIndex has a value of 'false', sbiSnmpdOperStatus returns 'disabled' and the SNMP daemon will not receive SNMP requests until sbiSnmpdAdminStatus variable has been set to 'inService'.\"",
    "::=",
    "{",
    "sysBootInfo",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "persistOK",
            1
          ],
          [
            "noPersistFile",
            2
          ],
          [
            "persistMismatch",
            3
          ],
          [
            "persistIndexFailure",
            4
          ],
          [
            "persistDisabled",
            5
          ],
          [
            "persistInvalid",
            6
          ],
          [
            "persistBoot",
            7
          ],
          [
            "persistInit",
            8
          ],
          [
            "persistInProgress",
            9
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The value of sbiPersistStatus indicates the state of the rebuild of the SNMP persistent index database upon reboot of the system. persistOK (1) - The persistent index database was successfully created. Persistent SNMP managed objects were recreated with the same SNMP indexes they had prior to the system reboot. noPersistFile (2) - There was no persistent index file with the same pathname as the configuration file. persistMismatch (3) -The headers in the persistent index file and the configuration file with the same name do not match. persistIndexFailure (4) - An error occurred while creating the persistent index database. persistDisabled (5) - The system was administratively reconfigured without maintaining persistent SNMP index values because sbiPersistIndex has a value of 'false'. persistInvalid (6) - Persistent index database was not initialized. persistBoot(7) - The persistent index database was in the pre-initial bootup state. persistInit(8) - The persistent index database is initializing. persistInProgress(9) - The initial bootup file is loading, using the persist index database. Once complete, the persist state will go to 'persistOK (1)' if successful. If sbiConfigStatus has a value of 'configOK' and sbiPersistStatus has any value other than 'persistOK', the system was reconfigured without maintaining persistent SNMP index values. Unless sbiPersistIndex has a value of 'false', sbiSnmpdOperStatus returns 'disabled' and the SNMP daemon will not receive SNMP requests until sbiSnmpdAdminStatus variable has been set to 'inService'."
    ],
    null,
    null,
    null,
    null
  ]
}
  • Nokia networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: TIMETRA-SYSTEM-MIB

    Vendor MIB copy from the LibreNMS archive. Nokia support.

    Module: TIMETRA-SYSTEM-MIB

    See published definition above

    Module imports
    {'HCNUM-TC': ['CounterBasedGauge64'], 'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'MacAddress', 'RowPointer', 'RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['Counter32', 'Counter64', 'Gauge32', 'Integer32', 'IpAddress', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'TIMETRA-TC-MIB': ['IpAddressPrefixLength', 'TDSCPNameOrEmpty', 'TItemDescription', 'TLDisplayString', 'TLNamedItem', 'TLNamedItemOrEmpty', 'TNamedItem', 'TNamedItemOrEmpty', 'TTcpUdpPort', 'TmnxActionType', 'TmnxAdminState', 'TmnxAdminStateTruthValue', 'TmnxBofDisplayStringURL', 'TmnxCliEngine', 'TmnxDisplayStringURL', 'TmnxEnabledDisabled', 'TmnxEnabledDisabledAdminState', 'TmnxFPNumberOrZero', 'TmnxLongDisplayString', 'TmnxOperState', 'TmnxScriptAuthType', 'TmnxServId', 'TmnxUuid', 'TmnxVRtrID', 'TmnxVRtrIDOrZero'], 'TIMETRA-LOG-MIB': ['tmnxEhsHEntryMinDelay', 'tmnxEhsHEntryMinDelayInterval', 'tmnxEhsHEntryScriptPlcyName', 'tmnxEhsHEntryScriptPlcyOwner', 'tmnxEhsHandlerDescription', 'tmnxLogExecRollbackOpIndex', 'tmnxLogExecRollbackOpType'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength', 'InetAddressType', 'InetPortNumber'], 'DISMAN-SCRIPT-MIB': ['smLaunchEntry', 'smLaunchError', 'smLaunchName', 'smLaunchOwner', 'smLaunchScriptName', 'smLaunchScriptOwner', 'smRunEntry', 'smRunIndex'], 'SNMP-COMMUNITY-MIB': ['snmpCommunityEntry'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRConfs', 'tmnxSRNotifyPrefix', 'tmnxSRObjs'], 'TIMETRA-CHASSIS-MIB': ['TmnxSlotNum', 'tmnxChassisBaseMacAddress', 'tmnxChassisIndex', 'tmnxChassisNotifyHwIndex', 'tmnxCpmCardNum', 'tmnxCpmCardSlotNum', 'tmnxFabricSlotNum', 'tmnxHwClass', 'tmnxHwID']}
    · Download TIMETRA-SYSTEM-MIB
  • Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community) · Publisher's source file: TIMETRA-SYSTEM-MIB

    Vendor MIB copy from the LibreNMS archive.

    Module: TIMETRA-SYSTEM-MIB

    Same published definition

    Module imports
    {'HCNUM-TC': ['CounterBasedGauge64'], 'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'MacAddress', 'RowPointer', 'RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['Counter32', 'Counter64', 'Gauge32', 'Integer32', 'IpAddress', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'TIMETRA-TC-MIB': ['IpAddressPrefixLength', 'TDSCPNameOrEmpty', 'TItemDescription', 'TLDisplayString', 'TLNamedItem', 'TLNamedItemOrEmpty', 'TNamedItem', 'TNamedItemOrEmpty', 'TTcpUdpPort', 'TmnxActionType', 'TmnxAdminState', 'TmnxAdminStateTruthValue', 'TmnxBofDisplayStringURL', 'TmnxCliEngine', 'TmnxDisplayStringURL', 'TmnxEnabledDisabled', 'TmnxEnabledDisabledAdminState', 'TmnxFPNumberOrZero', 'TmnxLongDisplayString', 'TmnxOperState', 'TmnxScriptAuthType', 'TmnxServId', 'TmnxUuid', 'TmnxVRtrID', 'TmnxVRtrIDOrZero'], 'TIMETRA-LOG-MIB': ['tmnxEhsHEntryMinDelay', 'tmnxEhsHEntryMinDelayInterval', 'tmnxEhsHEntryScriptPlcyName', 'tmnxEhsHEntryScriptPlcyOwner', 'tmnxEhsHandlerDescription', 'tmnxLogExecRollbackOpIndex', 'tmnxLogExecRollbackOpType'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength', 'InetAddressType', 'InetPortNumber'], 'DISMAN-SCRIPT-MIB': ['smLaunchEntry', 'smLaunchError', 'smLaunchName', 'smLaunchOwner', 'smLaunchScriptName', 'smLaunchScriptOwner', 'smRunEntry', 'smRunIndex'], 'SNMP-COMMUNITY-MIB': ['snmpCommunityEntry'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRConfs', 'tmnxSRNotifyPrefix', 'tmnxSRObjs'], 'TIMETRA-CHASSIS-MIB': ['TmnxSlotNum', 'tmnxChassisBaseMacAddress', 'tmnxChassisIndex', 'tmnxChassisNotifyHwIndex', 'tmnxCpmCardNum', 'tmnxCpmCardSlotNum', 'tmnxFabricSlotNum', 'tmnxHwClass', 'tmnxHwID']}
    · Download TIMETRA-SYSTEM-MIB

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.6527)

Marcelo Mourier

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.6527)

Jason Sterne

Siblings (15)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.6527.3.1.2.1.5.1 sbiConfigStatus00
1.3.6.1.4.1.6527.3.1.2.1.5.3 sbiPersistIndex00
1.3.6.1.4.1.6527.3.1.2.1.5.4 sbiSnmpdAdminStatus00
1.3.6.1.4.1.6527.3.1.2.1.5.5 sbiSnmpdOperStatus00
1.3.6.1.4.1.6527.3.1.2.1.5.6 sbiSnmpdMaxPktSize00
1.3.6.1.4.1.6527.3.1.2.1.5.7 sbiSnmpdPortNum00
1.3.6.1.4.1.6527.3.1.2.1.5.8 sbiBootConfigOKScript00
1.3.6.1.4.1.6527.3.1.2.1.5.9 sbiConfigOKScriptStatus00
1.3.6.1.4.1.6527.3.1.2.1.5.10 sbiBootConfigFailScript00
1.3.6.1.4.1.6527.3.1.2.1.5.11 sbiConfigFailScriptStatus00
1.3.6.1.4.1.6527.3.1.2.1.5.12 sbiRedSwitchoverScript00
1.3.6.1.4.1.6527.3.1.2.1.5.13 sbiRedSwitchoverScriptStatus00
1.3.6.1.4.1.6527.3.1.2.1.5.14 sbiAllowBootLicenseViolations00
1.3.6.1.4.1.6527.3.1.2.1.5.15 sbiSnmpdMaxBulkDuration00
1.3.6.1.4.1.6527.3.1.2.1.5.16 sbiSnmpdTransportProtocol00