Description 1
The value of tmnxOamFindEgrDiagNextHopAddress indicates the next hop address selected by SROS for the specified test.
Sources for this description
Nokia networking MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.6527.3.1.2.11.6.3.1.7
The value of tmnxOamFindEgrDiagNextHopAddress indicates the next hop address selected by SROS for the specified test.
Identification
{1 3 6 1 4 1 6527 3 1 2 11 6 3 1 7}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: tmnxOamDiagCtlOwnerIndex, tmnxOamDiagCtlTestIndex, tmnxOamDiagResultsTestRunIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.6527.3.1.2.11.6.3.1.7
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
tmnxOamFindEgrDiagNextHopAddress OBJECT-TYPE
SYNTAX InetAddress (SIZE (0|4|16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxOamFindEgrDiagNextHopAddress indicates the next hop
address selected by SROS for the specified test."
::= { tmnxOamFindEgrDiagResultsEntry 7 }tmnxOamFindEgrDiagNextHopAddress OBJECT-TYPE
SYNTAX InetAddress (SIZE (0|4|16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxOamFindEgrDiagNextHopAddress indicates the next hop
address selected by SROS for the specified test run."
::= { tmnxOamFindEgrDiagResultsEntry 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
The value of tmnxOamFindEgrDiagNextHopAddress indicates the next hop address selected by SROS for the specified test.
Nokia networking MIB copies (LibreNMS/Observium Community)
Description 2
The value of tmnxOamFindEgrDiagNextHopAddress indicates the next hop address selected by SROS for the specified test run.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Nokia networking MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: tmnxOamFindEgrDiagNextHopAddress
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxOamFindEgrDiagNextHopAddress",
"OBJECT-TYPE",
"SYNTAX",
"InetAddress",
"(",
"SIZE",
"(",
"0",
"|",
"4",
"|",
"16",
")",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tmnxOamFindEgrDiagNextHopAddress indicates the next hop address selected by SROS for the specified test.\"",
"::=",
"{",
"tmnxOamFindEgrDiagResultsEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"InetAddress",
[
"octetStringSubType",
[
[
0
],
[
4
],
[
16
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tmnxOamFindEgrDiagNextHopAddress indicates the next hop address selected by SROS for the specified test."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Nokia support.
Module: TIMETRA-OAM-TEST-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'OSPF-MIB': ['RouterID'], 'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'MacAddress', 'RowStatus', 'StorageType', 'TEXTUAL-CONVENTION', 'TimeStamp', 'TruthValue'], 'ATM-TC-MIB': ['AtmVcIdentifier', 'AtmVpIdentifier'], 'SNMPv2-SMI': ['Counter32', 'Counter64', 'Gauge32', 'Integer32', 'IpAddress', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'MPLS-LDP-MIB': ['MplsLabel'], 'TIMETRA-TC-MIB': ['Dot1PPriority', 'IpAddressPrefixLength', 'SdpBindId', 'TDSCPName', 'TDSCPNameOrEmpty', 'TFCName', 'TItemDescription', 'TLNamedItem', 'TLNamedItemOrEmpty', 'TNamedItem', 'TNamedItemOrEmpty', 'TPolicyStatementNameOrEmpty', 'TProfile', 'TmnxActionType', 'TmnxAdminState', 'TmnxBfdOnLspSessFecType', 'TmnxBgpRouteTarget', 'TmnxEnabledDisabled', 'TmnxEnabledDisabledAdminState', 'TmnxEncapVal', 'TmnxHigh32', 'TmnxIgpInstance', 'TmnxLow32', 'TmnxMplsTpGlobalID', 'TmnxMplsTpNodeID', 'TmnxPortID', 'TmnxPwGlobalIdOrZero', 'TmnxServId', 'TmnxSpokeSdpIdOrZero', 'TmnxStrSapId', 'TmnxTunnelID', 'TmnxTunnelType', 'TmnxVPNRouteDistinguisher', 'TmnxVRtrID', 'TmnxVRtrIDOrZero', 'TmnxVcId', 'TmnxVcIdOrNone'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepIdOrZero'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressPrefixLength', 'InetAddressType', 'InetPortNumber'], 'TIMETRA-SERV-MIB': ['SdpBindVcType', 'SdpId'], 'TIMETRA-VRTR-MIB': ['vRtrID', 'vRtrIfIndex'], 'TIMETRA-TC-MG-MIB': ['TmnxMobGwId'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRConfs', 'tmnxSRNotifyPrefix', 'tmnxSRObjs']}Status in source: current.
Names: tmnxOamFindEgrDiagNextHopAddress
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxOamFindEgrDiagNextHopAddress",
"OBJECT-TYPE",
"SYNTAX",
"InetAddress",
"(",
"SIZE",
"(",
"0",
"|",
"4",
"|",
"16",
")",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tmnxOamFindEgrDiagNextHopAddress indicates the next hop address selected by SROS for the specified test run.\"",
"::=",
"{",
"tmnxOamFindEgrDiagResultsEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"InetAddress",
[
"octetStringSubType",
[
[
0
],
[
4
],
[
16
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tmnxOamFindEgrDiagNextHopAddress indicates the next hop address selected by SROS for the specified test run."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. Nokia support.
Module: TIMETRA-OAM-TEST-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'OSPF-MIB': ['RouterID'], 'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'MacAddress', 'RowStatus', 'StorageType', 'TEXTUAL-CONVENTION', 'TimeStamp', 'TruthValue'], 'ATM-TC-MIB': ['AtmVcIdentifier', 'AtmVpIdentifier'], 'SNMPv2-SMI': ['Counter32', 'Counter64', 'Gauge32', 'Integer32', 'IpAddress', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'MPLS-LDP-MIB': ['MplsLabel'], 'TIMETRA-TC-MIB': ['Dot1PPriority', 'IpAddressPrefixLength', 'SdpBindId', 'ServiceOperStatus', 'TDSCPName', 'TDSCPNameOrEmpty', 'TFCName', 'TItemDescription', 'TLNamedItem', 'TLNamedItemOrEmpty', 'TNamedItem', 'TNamedItemOrEmpty', 'TPolicyStatementNameOrEmpty', 'TProfile', 'TmnxActionType', 'TmnxAdminState', 'TmnxBfdOnLspSessFecType', 'TmnxBgpRouteTarget', 'TmnxEnabledDisabled', 'TmnxEnabledDisabledAdminState', 'TmnxEncapVal', 'TmnxHigh32', 'TmnxIgpInstance', 'TmnxLow32', 'TmnxMplsTpGlobalID', 'TmnxMplsTpNodeID', 'TmnxPortID', 'TmnxPwGlobalIdOrZero', 'TmnxServId', 'TmnxSpokeSdpIdOrZero', 'TmnxStrSapId', 'TmnxTunnelID', 'TmnxTunnelType', 'TmnxVPNRouteDistinguisher', 'TmnxVRtrID', 'TmnxVRtrIDOrZero', 'TmnxVcId', 'TmnxVcIdOrNone'], 'TIMETRA-LAG-MIB': ['tLagIndex'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepIdOrZero'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressPrefixLength', 'InetAddressType', 'InetPortNumber'], 'TIMETRA-PORT-MIB': ['tmnxPortPortID'], 'TIMETRA-SERV-MIB': ['SdpBindVcType', 'SdpId'], 'TIMETRA-VRTR-MIB': ['vRtrID', 'vRtrIfIndex'], 'TIMETRA-TC-MG-MIB': ['TmnxMobGwId'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRConfs', 'tmnxSRNotifyPrefix', 'tmnxSRObjs']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6527.3.1.2.11.6.3.1.1 | tmnxOamDiagResultsTestRunIndex | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.11.6.3.1.2 | tmnxOamFindEgrDiagOperState | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.11.6.3.1.3 | tmnxOamFindEgrDiagEgressPort | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.11.6.3.1.4 | tmnxOamFindEgrDiagEgrRtrInstName | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.11.6.3.1.5 | tmnxOamFindEgrDiagEgressIfName | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.11.6.3.1.6 | tmnxOamFindEgrDiagNextHopAddrTyp | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.11.6.3.1.8 | tmnxOamFindEgrDiagResultType | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.11.6.3.1.9 | tmnxOamFindEgrDiagEgrSapPort | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.11.6.3.1.10 | tmnxOamFindEgrDiagEgrSapEncapVal | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.11.6.3.1.11 | tmnxOamFindEgrDiagEgrServiceId | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.11.6.3.1.12 | tmnxOamFindEgrDiagNextHopMAC | 0 | 0 |