Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxDot3OamTriggerFault",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"none",
"(",
"1",
")",
",",
"dyingGasp",
"(",
"2",
")",
",",
"criticalEvent",
"(",
"3",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tmnxDot3OamTriggerFault specifies the type of fault which is triggered. If the value of tmnxDot3OamTriggerFault is set to a value other than 'none (1)', EFM-OAM will bring the port operationally down (if it was not already), and set the appropriate fault flag in all subsequent Information OAMPDUs transmitted to the peer. If the value of tmnxDot3OamTriggerFault is set to 'none (1)', EFM-OAM will affect the port state as it would during normal operation and will not set the configured fault flags in the Information OAMPDUs transmitted to the peer unless some other configuration or state causes it to do so.\"",
"DEFVAL",
"{",
"none",
"}",
"::=",
"{",
"tmnxDot3OamEntry",
"20",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"none",
1
],
[
"dyingGasp",
2
],
[
"criticalEvent",
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tmnxDot3OamTriggerFault specifies the type of fault which is triggered. If the value of tmnxDot3OamTriggerFault is set to a value other than 'none (1)', EFM-OAM will bring the port operationally down (if it was not already), and set the appropriate fault flag in all subsequent Information OAMPDUs transmitted to the peer. If the value of tmnxDot3OamTriggerFault is set to 'none (1)', EFM-OAM will affect the port state as it would during normal operation and will not set the configured fault flags in the Information OAMPDUs transmitted to the peer unless some other configuration or state causes it to do so."
],
null,
null,
null,
[
"DEFVAL",
"none"
]
]
}