The value of tmnxMobGwNtfyChrgRefPointType indicates the type of reference point for the charging application.
Sources for this description
Nokia networking MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.6527.3.1.2.70.3.17
The value of tmnxMobGwNtfyChrgRefPointType indicates the type of reference point for the charging application.
Identification
{1 3 6 1 4 1 6527 3 1 2 70 3 17}
| Value | Name |
|---|---|
| 1 | rf |
| 2 | ga |
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
tmnxMobGwNtfyChrgRefPointType OBJECT-TYPE
SYNTAX INTEGER {
rf (1),
ga (2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxMobGwNtfyChrgRefPointType indicates the type of
reference point for the charging application."
::= { tmnxMobGatewayNotificationObjs 17 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The value of tmnxMobGwNtfyChrgRefPointType indicates the type of reference point for the charging application.
Nokia networking MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: tmnxMobGwNtfyChrgRefPointType
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxMobGwNtfyChrgRefPointType",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"rf",
"(",
"1",
")",
",",
"ga",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"accessible-for-notify",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tmnxMobGwNtfyChrgRefPointType indicates the type of reference point for the charging application.\"",
"::=",
"{",
"tmnxMobGatewayNotificationObjs",
"17",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"rf",
1
],
[
"ga",
2
]
]
]
],
null,
[
"MaxAccessPart",
"accessible-for-notify"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tmnxMobGwNtfyChrgRefPointType indicates the type of reference point for the charging application."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Nokia support.
Module: TIMETRA-MOBILE-GATEWAY-MIB
See published definition above
{'SNMPv2-TC': ['RowStatus', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Counter32', 'Gauge32', 'Integer32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'TIMETRA-TC-MIB': ['TmnxVRtrID', 'TItemDescription', 'TmnxOperState', 'TmnxEnabledDisabled', 'TmnxThresholdGroupType', 'TNamedItem', 'TNamedItemOrEmpty'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'TIMETRA-VRTR-MIB': ['vRtrID'], 'TIMETRA-TC-MG-MIB': ['TmnxMobGwType', 'TmnxMobPeerType', 'TmnxMobProfName', 'TmnxMobGwId', 'TmnxMobPathMgmtState', 'TmnxMobDiaPathMgmtState', 'TmnxMobDiaDetailPathMgmtState', 'TmnxMobDfPeerId', 'TmnxMobLiTarget', 'TmnxMobLiTargetType'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRObjs', 'tmnxSRConfs', 'tmnxSRNotifyPrefix'], 'TIMETRA-CHASSIS-MIB': ['tmnxChassisIndex', 'tmnxCardSlotNum'], 'TIMETRA-MOBILE-PROFILE-MIB': ['tmnxMobProfDiaPeerName', 'tmnxMobProfDiaPeerListIndex', 'tmnxMobGtpPriServerAddrType', 'tmnxMobGtpPriServerAddr', 'tmnxMobGtpPriServerPort']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6527.3.1.2.70.3.1 | tmnxMobGwNtfyGatewayId | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.2 | tmnxMobGwNtfyVrtrId | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.3 | tmnxMobGwNtfyRefPointType | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.4 | tmnxMobGwNtfyRefPointProtocol | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.5 | tmnxMobGwNtfyRfPtPeerAddrType | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.6 | tmnxMobGwNtfyRfPtPeerAddr | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.7 | tmnxMobGwNtfyRfPtPeerPort | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.8 | tmnxMobGwNtfyPathMgmtPeerState | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.9 | tmnxMobGwNtfyDiaRefPointType | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.10 | tmnxMobGwNtfyDiaPeerName | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.11 | tmnxMobGwNtfyDiaPeerIndex | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.12 | tmnxMobGwNtfyDiaPeerAddrType | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.13 | tmnxMobGwNtfyDiaPeerAddr | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.14 | tmnxMobGwNtfyDiaPeerPort | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.15 | tmnxMobGwNtfyDiameterPeerState | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.16 | tmnxMobGwNtfyDiameterReasonCode | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.18 | tmnxMobGwNtfyPriCdfDiaPeer | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.19 | tmnxMobGwNtfySecCdfDiaPeer | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.20 | tmnxMobGwNtfyCdfDiaPeer | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.21 | tmnxMobGwNtfyFlashId | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.22 | tmnxMobGwNtfyCfLimit | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.23 | tmnxMobGwNtfyAcrFailureType | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.24 | tmnxMobGwNtfyGtpPriGrpName | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.25 | tmnxMobGwNtfyGtpPriServIndex | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.26 | tmnxMobGwNtfyGtpPriServAddrType | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.27 | tmnxMobGwNtfyGtpPriServAddr | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.28 | tmnxMobGwNtfyGtpPriServPort | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.29 | tmnxMobGwNtfyNewGtpPriServIndex | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.30 | tmnxMobGwNtfyNewGtpPriSrvAdrType | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.31 | tmnxMobGwNtfyNewGtpPriServAddr | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.32 | tmnxMobGwNtfyNewGtpPriServPort | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.33 | tmnxMobGwNtfyRadGrpName | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.34 | tmnxMobGwNtfyRadPeerIndex | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.35 | tmnxMobGwNtfyRadPeerAddrType | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.36 | tmnxMobGwNtfyRadPeerAddr | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.37 | tmnxMobGwNtfyRadPeerAuthPort | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.38 | tmnxMobGwNtfyGtpPriServerState | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.39 | tmnxMobGwNtfyGtpPriSvrReasonCode | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.40 | tmnxMobGwNtfyGtpPriGrpState | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.41 | tmnxMobGwNtfyGtpPriGrpReasonCode | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.42 | tmnxMobGwNtfySysGroupId | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.43 | tmnxMobGwNtfyWriteCdrAction | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.44 | tmnxMobGwNtfyRadPeerAcctPort | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.45 | tmnxMobGwNtfyRadPeerState | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.70.3.46 | tmnxMobGwNtfyRadGrpState | 0 | 0 |