The value of tmnxMobPdnBcTnlRemoteTeid indicates the Tunnel Endpoint Identifier (TEID) of the Serving Gateway (SGW) on the S5 or S8 reference point.
Sources for this description
Nokia networking MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.6527.3.1.2.71.2.3.1.8
The value of tmnxMobPdnBcTnlRemoteTeid indicates the Tunnel Endpoint Identifier (TEID) of the Serving Gateway (SGW) on the S5 or S8 reference point.
Identification
{1 3 6 1 4 1 6527 3 1 2 71 2 3 1 8}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: tmnxMobGwId, tmnxMobPdnUeImsi, tmnxMobPdnPcApn, tmnxMobPdnPcPdnType, tmnxMobPdnBcBearerId.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.6527.3.1.2.71.2.3.1.8
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
tmnxMobPdnBcTnlRemoteTeid OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxMobPdnBcTnlRemoteTeid indicates the Tunnel Endpoint
Identifier (TEID) of the Serving Gateway (SGW) on the S5 or S8
reference point."
::= { tmnxMobPdnBearerContextEntry 8 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The value of tmnxMobPdnBcTnlRemoteTeid indicates the Tunnel Endpoint Identifier (TEID) of the Serving Gateway (SGW) on the S5 or S8 reference point.
Nokia networking MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: tmnxMobPdnBcTnlRemoteTeid
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxMobPdnBcTnlRemoteTeid",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tmnxMobPdnBcTnlRemoteTeid indicates the Tunnel Endpoint Identifier (TEID) of the Serving Gateway (SGW) on the S5 or S8 reference point.\"",
"::=",
"{",
"tmnxMobPdnBearerContextEntry",
"8",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tmnxMobPdnBcTnlRemoteTeid indicates the Tunnel Endpoint Identifier (TEID) of the Serving Gateway (SGW) on the S5 or S8 reference point."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Nokia support.
Module: TIMETRA-MOBILE-PDN-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TimeStamp', 'TruthValue', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Counter64', 'Gauge32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'TIMETRA-TC-MIB': ['TmnxEnabledDisabled', 'TmnxVRtrID', 'TmnxAdminState', 'TmnxOperState', 'TItemDescription', 'TTcpUdpPort', 'TTcpUdpPortOperator', 'TNamedItemOrEmpty', 'TmnxEnabledDisabledOrInherit', 'TmnxCdrType', 'TmnxQosBytesHex', 'TNamedItem', 'TmnxCdrDiagnosticAction', 'TmnxBsxIsaAaGroupIndexOrZero'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetAddressPrefixLength', 'InetPortNumber'], 'TIMETRA-VRTR-MIB': ['vRtrID', 'vRtrIpPoolName'], 'TIMETRA-TC-MG-MIB': ['TmnxMobProfName', 'TmnxMobProfNameOrEmpty', 'TmnxMobDiaRetryCount', 'TmnxMobDiaTransTimer', 'TmnxMobDiaPeerHost', 'TmnxMobNode', 'TmnxMobRtrAdvtInterval', 'TmnxMobRtrAdvtLifeTime', 'TmnxMobAddrScheme', 'TmnxMobApn', 'TmnxMobApnOrZero', 'TmnxMobChargingProfile', 'TmnxMobAuthType', 'TmnxMobAuthUserName', 'TmnxMobProfMbrRate', 'TmnxMobServerState', 'TmnxMobChargingBearerType', 'TmnxMobChargingLevel', 'TmnxMobImsi', 'TmnxMobMsisdn', 'TmnxMobImei', 'TmnxMobNai', 'TmnxMobMcc', 'TmnxMobMnc', 'TmnxMobUeState', 'TmnxMobUeRat', 'TmnxMobPdnType', 'TmnxMobPdnSessionState', 'TmnxMobPdnSessionEvent', 'TmnxMobPgwSigProtocol', 'TmnxMobBearerId', 'TmnxMobBearerType', 'TmnxMobQci', 'TmnxMobArp', 'TmnxMobSdf', 'TmnxMobSdfRuleName', 'TmnxMobSdfFilterDirection', 'TmnxMobSdfFilterProtocol', 'TmnxMobSdfFilter', 'TmnxMobSdfFilterNum', 'TmnxMobRfAcctLevel', 'TmnxMobIpCanType', 'TmnxMobStaticPolPrecedence', 'TmnxMobDiaPathMgmtState', 'TmnxMobDiaDetailPathMgmtState', 'TmnxMobDualStackPref', 'TmnxMobPeerType', 'TmnxMobGwId', 'TmnxMobPathMgmtState', 'TmnxMobChargingProfileOrInherit', 'TmnxMobUeSubType', 'TmnxMobQciValueOrZero', 'TmnxMobArpValueOrZero', 'TmnxMobUeId', 'TmnxMobUeIdType', 'TmnxMobImsiStr', 'TmnxMobRatingGrpState', 'TmnxMobPdnRefPointType', 'TmnxMobPresenceState', 'TmnxMobPdnGyChrgTriggerType', 'TmnxMobAccessType', 'TmnxMobUeStrPrefix'], 'TIMETRA-BSX-NG-MIB': ['TmnxBsxAaGrpPartIndex'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRObjs', 'tmnxSRConfs'], 'TIMETRA-CHASSIS-MIB': ['tmnxChassisIndex', 'tmnxCardSlotNum', 'TmnxSlotNumOrZero'], 'TIMETRA-MOBILE-GATEWAY-MIB': ['tmnxMobGwId'], 'TIMETRA-MOBILE-PROFILE-MIB': ['tmnxMobProfPolBaseName', 'tmnxMobProfDiaPeerName', 'tmnxMobProfDiaPeerListIndex', 'tmnxMobGtpPriGrpName', 'tmnxMobGtpPriServerIndex', 'tmnxMobProfRadGrpName', 'tmnxMobProfRadPeerIndex', 'tmnxMobProfChgUnitRatingGroup', 'tmnxMobProfChgUnitServIdentifier']}Related source files and packages: