Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxPtpClockAnnounceInterval",
"OBJECT-TYPE",
"SYNTAX",
"TmnxPtpLogInterval",
"(",
"-",
"3",
".",
".",
"4",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tmnxPtpClockAnnounceInterval specifies the packet rate requested in REQUEST_UNICAST_TRANSMISSION signaling messages for announce packets. The default value of tmnxPtpClockAnnounceInterval depends on the value of tmnxPtpClockProfile. If tmnxPtpClockProfile is 'g8265dot1-2010 (1)', or 'ieee1588-2008 (2)', the default value is 1, corresponding to an announce packet rate of 1 packet every 2 seconds. If tmnxPtpClockProfile is 'g8275dot1-2014 (3)', the default value is -3, corresponding to an announce packet rate of 8 packets per second. This object corresponds to the portDS.logAnnounceInterval data set member of IEEE 1588-2008. In the SROS implementation, all PTP ports have the same configured value of portDS.logAnnounceInterval. This object can only be modified if tmnxPtpClockAdminState is set to 'outOfService (3)', otherwise an 'inconsistentValue' error is returned.\"",
"REFERENCE",
"\"ITU-T draft G.8265.1 V0.3, Section 6.5 and IEEE Std 1588-2008 Sections 7.7.2.2 and 8.2.5.4.1\"",
"::=",
"{",
"tmnxPtpClockConfig",
"5",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"TmnxPtpLogInterval",
[
"integerSubType",
[
[
-3,
4
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tmnxPtpClockAnnounceInterval specifies the packet rate requested in REQUEST_UNICAST_TRANSMISSION signaling messages for announce packets. The default value of tmnxPtpClockAnnounceInterval depends on the value of tmnxPtpClockProfile. If tmnxPtpClockProfile is 'g8265dot1-2010 (1)', or 'ieee1588-2008 (2)', the default value is 1, corresponding to an announce packet rate of 1 packet every 2 seconds. If tmnxPtpClockProfile is 'g8275dot1-2014 (3)', the default value is -3, corresponding to an announce packet rate of 8 packets per second. This object corresponds to the portDS.logAnnounceInterval data set member of IEEE 1588-2008. In the SROS implementation, all PTP ports have the same configured value of portDS.logAnnounceInterval. This object can only be modified if tmnxPtpClockAdminState is set to 'outOfService (3)', otherwise an 'inconsistentValue' error is returned."
],
[
"REFERENCE",
"ITU-T draft G.8265.1 V0.3, Section 6.5 and IEEE Std 1588-2008 Sections 7.7.2.2 and 8.2.5.4.1"
],
null,
null,
null
]
}