Status in source: current.
Names: tmnxRadSrvPlcyAcctStopMaxItvl
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxRadSrvPlcyAcctStopMaxItvl",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"3600",
")",
"UNITS",
[
"literal",
"227365636f6e647322"
],
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tmnxRadSrvPlcyAcctStopMaxItvl specifies the maximum interval (in seconds) between retries to send the RADIUS accounting stop message. The value '0' specifies that no retries are performed. The value specified must be bigger then or equal to the value specified for the object tmnxRadSrvPlcyAcctStopMinItvl. If a value '0' is specified for any of the objects tmnxRadSrvPlcyAcctStopMinItvl, tmnxRadSrvPlcyAcctStopMaxItvl, or tmnxRadSrvPlcyAcctStoplifetim, then all 3 objects will be set to '0' by the system.\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"tmnxRadSrvPlcyEntry",
"116",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
3600
]
]
]
],
[
"UNITS",
"seconds"
],
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tmnxRadSrvPlcyAcctStopMaxItvl specifies the maximum interval (in seconds) between retries to send the RADIUS accounting stop message. The value '0' specifies that no retries are performed. The value specified must be bigger then or equal to the value specified for the object tmnxRadSrvPlcyAcctStopMinItvl. If a value '0' is specified for any of the objects tmnxRadSrvPlcyAcctStopMinItvl, tmnxRadSrvPlcyAcctStopMaxItvl, or tmnxRadSrvPlcyAcctStoplifetim, then all 3 objects will be set to '0' by the system."
],
null,
null,
null,
[
"DEFVAL",
0
]
]
}
- Nokia networking MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Nokia support.
Module: TIMETRA-RADIUS-MIB
See published definition above
Module imports
{'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TEXTUAL-CONVENTION', 'TimeInterval', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['Counter32', 'Gauge32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'TIMETRA-TC-MIB': ['TItemDescription', 'TNamedItem', 'TNamedItemOrEmpty', 'TmnxAdminState', 'TmnxAuthPassword', 'TmnxDisplayStringURL', 'TmnxEnabledDisabled', 'TmnxOperState', 'TmnxRadiusPendingReqLimit', 'TmnxRadiusServerOperState', 'TmnxSubRadIsaServAlgorithm', 'TmnxSubRadServAlgorithm', 'TmnxSubRadiusAttrType', 'TmnxSubRadiusVendorId', 'TmnxVRtrIDOrZero', 'TmnxWlanGwIsaGrpIdOrZero'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'TIMETRA-VRTR-MIB': ['vRtrID', 'vRtrIfIndex'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRConfs', 'tmnxSRNotifyPrefix', 'tmnxSRObjs']}
· Download TIMETRA-RADIUS-MIB
Related source files and packages: