Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxOamPmCfgLossLmmConsecDeltaTs",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"2",
".",
".",
"10",
")",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tmnxOamPmCfgLossLmmConsecDeltaTs specifies the number of consecutive MEF-35 'delta_t's (also known as 'Small Time Intervals') which constitute a MEF-35 'Availability Window' when computing availability statistics for the specified session's LMM test. The availability parameters used by SROS for LMM tests (e.g. tmnxOamPmCfgLossLmmConsecDeltaTs) are modelled after the MEF-35 availability parameters defined for Synthetic Loss Measurement (SLM) tests. Hence, the REFERENCE text for this object is a MEF-35 SLM section. The duration of an Availability Window (in milliseconds) is tmnxOamPmCfgLossLmmTxFrmsPerDelT * tmnxOamPmCfgLossLmmInterval * tmnxOamPmCfgLossLmmConsecDeltaTs. An attempt to change the duration of an Availability Window to more than 100,000 milliseconds will be rejected. An attempt to change tmnxOamPmCfgLossLmmConsecDeltaTs to a value less than or equal to tmnxOamPmCfgLossLmmChliThreshold will be rejected.\"",
"REFERENCE",
"\"MEF-35, 'Service OAM Performance Monitoring Implementation Agreement', Metro Ethernet Forum, April 2012, Section 10.2 'Single-Ended Synthetic Loss Function for Frame Loss Ratio (FLR) and Availability'.\"",
"DEFVAL",
"{",
"10",
"}",
"::=",
"{",
"tmnxOamPmCfgLossLmmEntry",
"9",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
2,
10
]
]
]
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tmnxOamPmCfgLossLmmConsecDeltaTs specifies the number of consecutive MEF-35 'delta_t's (also known as 'Small Time Intervals') which constitute a MEF-35 'Availability Window' when computing availability statistics for the specified session's LMM test. The availability parameters used by SROS for LMM tests (e.g. tmnxOamPmCfgLossLmmConsecDeltaTs) are modelled after the MEF-35 availability parameters defined for Synthetic Loss Measurement (SLM) tests. Hence, the REFERENCE text for this object is a MEF-35 SLM section. The duration of an Availability Window (in milliseconds) is tmnxOamPmCfgLossLmmTxFrmsPerDelT * tmnxOamPmCfgLossLmmInterval * tmnxOamPmCfgLossLmmConsecDeltaTs. An attempt to change the duration of an Availability Window to more than 100,000 milliseconds will be rejected. An attempt to change tmnxOamPmCfgLossLmmConsecDeltaTs to a value less than or equal to tmnxOamPmCfgLossLmmChliThreshold will be rejected."
],
[
"REFERENCE",
"MEF-35, 'Service OAM Performance Monitoring Implementation Agreement', Metro Ethernet Forum, April 2012, Section 10.2 'Single-Ended Synthetic Loss Function for Frame Loss Ratio (FLR) and Availability'."
],
null,
null,
[
"DEFVAL",
10
]
]
}