Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxOamPmCfgThrLossChliRaise",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"-",
"1",
"|",
"1",
".",
".",
"864000",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tmnxOamPmCfgThrLossChliRaise specifies the raise threshold for Consecutive High Loss Intervals (CHLIs). Depending on the specified indices, tmnxOamPmCfgThrLossChliRaise is the raise threshold for: tmnxOamPmStsLossLmmChliBwd, tmnxOamPmStsLossLmmChliFwd + tmnxOamPmStsLossLmmChliBwd, tmnxOamPmStsLossLmmChliFwd, tmnxOamPmStsLossSlmChliBwd, tmnxOamPmStsLossSlmChliFwd + tmnxOamPmStsLossSlmChliBwd, tmnxOamPmStsLossSlmChliFwd, tmnxOamPmStsLossTwlChliBwd, tmnxOamPmStsLossTwlChliFwd + tmnxOamPmStsLossTwlChliBwd, or tmnxOamPmStsLossTwlChliFwd. For example, suppose: 1. OAM-PM loss TCAs are enabled for the 'mi15minutes(2)' measurement interval of the OAM-PM session OAM_PM_Eth_session_1 (using tmnxOamPmCfgMeasIntvlLossTCAs and tmnxOamPmCfgMeasIntvlTCAs). 2. tmnxOamPmCfgThrLossChliRaise is set to 7 for the indices {OAM_PM_Eth_session_1, 'slm(2)', 'forward(1)'}. 3. A 15 minute interval belonging to OAM_PM_Eth_session_1's SLM test has its forward CHLI count (i.e. tmnxOamPmStsLossSlmChliFwd) increase to 7. 4. Generating a CHLI Raise TCA is allowed (e.g. the most recent CHLI TCA for the specified indices was a Clear). Then, SROS immediately generates a CHLI Raise TCA (using tmnxOamPmThrRaise) for the 15-minute interval, for the forward direction. Negative one specifies that CHLI thresholding is disabled for the specified indices (i.e. SROS will not generate a Raise TCA, or a Clear TCA). tmnxOamPmCfgThrLossChliRaise must be greater than tmnxOamPmCfgThrLossChliClear. Exception: the combination tmnxOamPmCfgThrLossChliRaise=-1 and tmnxOamPmCfgThrLossChliClear=-1 is supported. tmnxOamPmCfgThrLossChliRaise and tmnxOamPmCfgThrLossChliClear must be set in the same SNMP Set PDU. The upper bound of this object is the maximum number of MEF-35 'delta_t' time intervals (also known as 'Small Time Intervals') which can occur in a 24 hour measurement interval.\"",
"REFERENCE",
"\"MEF-35, 'Service OAM Performance Monitoring Implementation Agreement', Metro Ethernet Forum, April 2012, Section 10.2 'Single-Ended Synthetic Loss Function for Frame Loss Ratio (FLR) and Availability'.\"",
"DEFVAL",
"{",
"-",
"1",
"}",
"::=",
"{",
"tmnxOamPmCfgThrLossFwBwAgEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
-1
],
[
1,
864000
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tmnxOamPmCfgThrLossChliRaise specifies the raise threshold for Consecutive High Loss Intervals (CHLIs). Depending on the specified indices, tmnxOamPmCfgThrLossChliRaise is the raise threshold for: tmnxOamPmStsLossLmmChliBwd, tmnxOamPmStsLossLmmChliFwd + tmnxOamPmStsLossLmmChliBwd, tmnxOamPmStsLossLmmChliFwd, tmnxOamPmStsLossSlmChliBwd, tmnxOamPmStsLossSlmChliFwd + tmnxOamPmStsLossSlmChliBwd, tmnxOamPmStsLossSlmChliFwd, tmnxOamPmStsLossTwlChliBwd, tmnxOamPmStsLossTwlChliFwd + tmnxOamPmStsLossTwlChliBwd, or tmnxOamPmStsLossTwlChliFwd. For example, suppose: 1. OAM-PM loss TCAs are enabled for the 'mi15minutes(2)' measurement interval of the OAM-PM session OAM_PM_Eth_session_1 (using tmnxOamPmCfgMeasIntvlLossTCAs and tmnxOamPmCfgMeasIntvlTCAs). 2. tmnxOamPmCfgThrLossChliRaise is set to 7 for the indices {OAM_PM_Eth_session_1, 'slm(2)', 'forward(1)'}. 3. A 15 minute interval belonging to OAM_PM_Eth_session_1's SLM test has its forward CHLI count (i.e. tmnxOamPmStsLossSlmChliFwd) increase to 7. 4. Generating a CHLI Raise TCA is allowed (e.g. the most recent CHLI TCA for the specified indices was a Clear). Then, SROS immediately generates a CHLI Raise TCA (using tmnxOamPmThrRaise) for the 15-minute interval, for the forward direction. Negative one specifies that CHLI thresholding is disabled for the specified indices (i.e. SROS will not generate a Raise TCA, or a Clear TCA). tmnxOamPmCfgThrLossChliRaise must be greater than tmnxOamPmCfgThrLossChliClear. Exception: the combination tmnxOamPmCfgThrLossChliRaise=-1 and tmnxOamPmCfgThrLossChliClear=-1 is supported. tmnxOamPmCfgThrLossChliRaise and tmnxOamPmCfgThrLossChliClear must be set in the same SNMP Set PDU. The upper bound of this object is the maximum number of MEF-35 'delta_t' time intervals (also known as 'Small Time Intervals') which can occur in a 24 hour measurement interval."
],
[
"REFERENCE",
"MEF-35, 'Service OAM Performance Monitoring Implementation Agreement', Metro Ethernet Forum, April 2012, Section 10.2 'Single-Ended Synthetic Loss Function for Frame Loss Ratio (FLR) and Availability'."
],
null,
null,
[
"DEFVAL",
-1
]
]
}