Status in source: current.
Names: tmnxOamPmCfgSessEthSrcMdIndex
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxOamPmCfgSessEthSrcMdIndex",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tmnxOamPmCfgSessEthSrcMdIndex specifies the source Ethernet Maintenance Domain (MD) index to be used by the specified session. The source domain can be specified using tmnxOamPmCfgSessEthSrcMdName or tmnxOamPmCfgSessEthSrcMdIndex (not both). tmnxOamPmCfgSessEthSrcMdName is the preferred object for specifying the source domain. One of tmnxOamPmCfgSessEthSrcMdName and tmnxOamPmCfgSessEthSrcMdIndex should be assigned a non-default value. Otherwise, an attempt to start any test belonging to the session will fail. If specified, tmnxOamPmCfgSessEthSrcMdIndex should match a domain created using TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMdMgmtRowStatus. Otherwise, the session's tests will fail. An attempt to change TIMETRA-SYSTEM-MIB::tmnxSysMgmtIfWriteMode.0 away from 'classic(1)' is blocked if any tmnxOamPmCfgSessEthSrcMdIndex has a non-default value. Zero indicates a value has not been configured.\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"tmnxOamPmCfgSessEthEntry",
"2",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tmnxOamPmCfgSessEthSrcMdIndex specifies the source Ethernet Maintenance Domain (MD) index to be used by the specified session. The source domain can be specified using tmnxOamPmCfgSessEthSrcMdName or tmnxOamPmCfgSessEthSrcMdIndex (not both). tmnxOamPmCfgSessEthSrcMdName is the preferred object for specifying the source domain. One of tmnxOamPmCfgSessEthSrcMdName and tmnxOamPmCfgSessEthSrcMdIndex should be assigned a non-default value. Otherwise, an attempt to start any test belonging to the session will fail. If specified, tmnxOamPmCfgSessEthSrcMdIndex should match a domain created using TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMdMgmtRowStatus. Otherwise, the session's tests will fail. An attempt to change TIMETRA-SYSTEM-MIB::tmnxSysMgmtIfWriteMode.0 away from 'classic(1)' is blocked if any tmnxOamPmCfgSessEthSrcMdIndex has a non-default value. Zero indicates a value has not been configured."
],
null,
null,
null,
[
"DEFVAL",
0
]
]
}
- Nokia networking MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Nokia support.
Module: TIMETRA-OAM-PM-MIB
See published definition above
Module imports
{'SNMPv2-TC': ['DateAndTime', 'MacAddress', 'RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['Counter32', 'Counter64', 'Gauge32', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'TIMETRA-TC-MIB': ['TDSCPName', 'TDSCPNameOrEmpty', 'TFCName', 'TItemDescription', 'TLNamedItem', 'TLNamedItemOrEmpty', 'TNamedItem', 'TNamedItemOrEmpty', 'TProfile', 'TmnxCreateOrigin', 'TmnxEnabledDisabled', 'TmnxEnabledDisabledOrNA'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepIdOrZero'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressPrefixLength', 'InetAddressType', 'InetPortNumber'], 'TIMETRA-SERV-MIB': ['svcId'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRConfs', 'tmnxSRNotifyPrefix', 'tmnxSRObjs']}
· Download TIMETRA-OAM-PM-MIB
Related source files and packages: