Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxOamPmCfgLossSlmChliThreshold",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"1",
".",
".",
"9",
")",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tmnxOamPmCfgLossSlmChliThreshold specifies the MEF-35 Consecutive High Loss Interval (CHLI) threshold for the specified session's SLM test. An attempt to change tmnxOamPmCfgLossSlmChliThreshold to a value greater than or equal to tmnxOamPmCfgLossSlmConsecDeltaTs will be rejected.\"",
"REFERENCE",
"\"MEF-35, 'Service OAM Performance Monitoring Implementation Agreement', Metro Ethernet Forum, April 2012, Section 10.2 'Single-Ended Synthetic Loss Function for Frame Loss Ratio (FLR) and Availability'.\"",
"DEFVAL",
"{",
"5",
"}",
"::=",
"{",
"tmnxOamPmCfgLossSlmEntry",
"9",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
1,
9
]
]
]
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tmnxOamPmCfgLossSlmChliThreshold specifies the MEF-35 Consecutive High Loss Interval (CHLI) threshold for the specified session's SLM test. An attempt to change tmnxOamPmCfgLossSlmChliThreshold to a value greater than or equal to tmnxOamPmCfgLossSlmConsecDeltaTs will be rejected."
],
[
"REFERENCE",
"MEF-35, 'Service OAM Performance Monitoring Implementation Agreement', Metro Ethernet Forum, April 2012, Section 10.2 'Single-Ended Synthetic Loss Function for Frame Loss Ratio (FLR) and Availability'."
],
null,
null,
[
"DEFVAL",
5
]
]
}