Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxOesCtlCommsDownReason",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"unknownReason",
"(",
"0",
")",
",",
"adminReboot",
"(",
"1",
")",
",",
"noResponse",
"(",
"2",
")",
",",
"configFailed",
"(",
"3",
")",
",",
"invalidSystem",
"(",
"4",
")",
",",
"invalidSoftware",
"(",
"5",
")",
",",
"oesUnreachable",
"(",
"6",
")",
",",
"adminEcSwitchOver",
"(",
"7",
")",
",",
"ctlCommsUnprov",
"(",
"8",
")",
",",
"clearActiveEcCard",
"(",
"9",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tmnxOesCtlCommsDownReason indicates the reason for the last time a loss of communication with the OES was detected. Values: unknownReason (0) - control communication failure for unknown reason adminReboot (1) - OES is rebooted via tmnxOesReboot noResponse (2) - no response was received for SNMP packet configFailed (3) - a SNMP SET, GET or GETNEXT during a configuration action did not complete correctly invalidSystem (4) - the OES sysObjectID does not contain the object identifier for a supported system invalidSoftware (5) - the OES software version is below the minimum supported version oesUnreachable (6) - OES is unreachable adminEcSwitchOver (7) - OES EC activity switch via tmnxOesChassisActivitySwitch ctlCommsUnprov (8) - missing or incomplete OES control communications provisioning clearActiveEcCard (9) - OES active EC clear via tmnxOesCardReboot\"",
"::=",
"{",
"tmnxOesStatObjs",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"unknownReason",
0
],
[
"adminReboot",
1
],
[
"noResponse",
2
],
[
"configFailed",
3
],
[
"invalidSystem",
4
],
[
"invalidSoftware",
5
],
[
"oesUnreachable",
6
],
[
"adminEcSwitchOver",
7
],
[
"ctlCommsUnprov",
8
],
[
"clearActiveEcCard",
9
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tmnxOesCtlCommsDownReason indicates the reason for the last time a loss of communication with the OES was detected. Values: unknownReason (0) - control communication failure for unknown reason adminReboot (1) - OES is rebooted via tmnxOesReboot noResponse (2) - no response was received for SNMP packet configFailed (3) - a SNMP SET, GET or GETNEXT during a configuration action did not complete correctly invalidSystem (4) - the OES sysObjectID does not contain the object identifier for a supported system invalidSoftware (5) - the OES software version is below the minimum supported version oesUnreachable (6) - OES is unreachable adminEcSwitchOver (7) - OES EC activity switch via tmnxOesChassisActivitySwitch ctlCommsUnprov (8) - missing or incomplete OES control communications provisioning clearActiveEcCard (9) - OES active EC clear via tmnxOesCardReboot"
],
null,
null,
null,
null
]
}