Status in source: current.
Names: tmnxMobGwRadGrpFailAlarmClrd
Technical details
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"tmnxMobGwRadGrpFailAlarmClrd",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"tmnxMobGwNtfyGatewayId",
",",
"tmnxMobGwNtfyVrtrId",
",",
"tmnxMobGwNtfyRadGrpName",
",",
"tmnxMobGwNtfyRadGrpState",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"A tmnxMobGwRadGrpFailAlarmClrd notification is generated when a previously failed Radius Server Group has at least one operational Radius Server. [CAUSE] The radius server group is recovered from the previous failure and at least one of its servers has transitioned to operating 'up' state. [EFFECT] When the radius server group is recovered from the previous failure and operation for the radius-group is back to normal. [RECOVERY] If the radius group is recovered from the previous failure, no further action is needed. \"",
"::=",
"{",
"tmnxMobGatewayNotifications",
"21",
"}"
],
"syntax_tree": [
[
"Objects",
[
"tmnxMobGwNtfyGatewayId",
"tmnxMobGwNtfyVrtrId",
"tmnxMobGwNtfyRadGrpName",
"tmnxMobGwNtfyRadGrpState"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A tmnxMobGwRadGrpFailAlarmClrd notification is generated when a previously failed Radius Server Group has at least one operational Radius Server. [CAUSE] The radius server group is recovered from the previous failure and at least one of its servers has transitioned to operating 'up' state. [EFFECT] When the radius server group is recovered from the previous failure and operation for the radius-group is back to normal. [RECOVERY] If the radius group is recovered from the previous failure, no further action is needed."
],
null
]
}
- Nokia networking MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Nokia support.
Module: TIMETRA-MOBILE-GATEWAY-MIB
See published definition above
Module imports
{'SNMPv2-TC': ['RowStatus', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Counter32', 'Gauge32', 'Integer32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'TIMETRA-TC-MIB': ['TmnxVRtrID', 'TItemDescription', 'TmnxOperState', 'TmnxEnabledDisabled', 'TmnxThresholdGroupType', 'TNamedItem', 'TNamedItemOrEmpty'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'TIMETRA-VRTR-MIB': ['vRtrID'], 'TIMETRA-TC-MG-MIB': ['TmnxMobGwType', 'TmnxMobPeerType', 'TmnxMobProfName', 'TmnxMobGwId', 'TmnxMobPathMgmtState', 'TmnxMobDiaPathMgmtState', 'TmnxMobDiaDetailPathMgmtState', 'TmnxMobDfPeerId', 'TmnxMobLiTarget', 'TmnxMobLiTargetType'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRObjs', 'tmnxSRConfs', 'tmnxSRNotifyPrefix'], 'TIMETRA-CHASSIS-MIB': ['tmnxChassisIndex', 'tmnxCardSlotNum'], 'TIMETRA-MOBILE-PROFILE-MIB': ['tmnxMobProfDiaPeerName', 'tmnxMobProfDiaPeerListIndex', 'tmnxMobGtpPriServerAddrType', 'tmnxMobGtpPriServerAddr', 'tmnxMobGtpPriServerPort']}
· Download TIMETRA-MOBILE-GATEWAY-MIB
Related source files and packages: