Status in source: current.
Names: tmnxOesDbSyncFailure
Technical details
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"tmnxOesDbSyncFailure",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"tmnxHwClass",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"The active Equipment Controller is unable to synchronize its database with the inactive Equipment Controller. [CAUSE] The tmnxOesDbSyncFailure notification may be raised under the following conditions: 1) An incorrectly seated Equipment Controller; 2) The software versions on the active and inactive Equipment Controllers are not compatible; 3) A hardware problem with one or both controllers. [EFFECT] The OES does not have redundancy protection between the two Equipment Controller cards. [RECOVERY] Proceed as follows to clear the Database Synchronization Failed alarm: 1) Remove the Equipment Controller with the condition and examine the connector on the back of the card for damage, including bent or broken pins; 2) Examine the connector on the backplane for damage. If there is damage to the backplane of the shelf, contact your service representative; 3) Re-insert the Equipment Controller into its original slot and allow the card to initialize; 4) Repeat Step 2) through Step 4) for the second Equipment Controller; 5) Replace the Equipment Controller with the alarm condition with a new unit. If the condition is not cleared, replace the second Equipment Controller with a new unit. Follow the return and repair process to return the faulty card to an authorized repair center for replacement.\"",
"::=",
"{",
"tmnxOesNotifications",
"3",
"}"
],
"syntax_tree": [
[
"Objects",
[
"tmnxHwClass"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The active Equipment Controller is unable to synchronize its database with the inactive Equipment Controller. [CAUSE] The tmnxOesDbSyncFailure notification may be raised under the following conditions: 1) An incorrectly seated Equipment Controller; 2) The software versions on the active and inactive Equipment Controllers are not compatible; 3) A hardware problem with one or both controllers. [EFFECT] The OES does not have redundancy protection between the two Equipment Controller cards. [RECOVERY] Proceed as follows to clear the Database Synchronization Failed alarm: 1) Remove the Equipment Controller with the condition and examine the connector on the back of the card for damage, including bent or broken pins; 2) Examine the connector on the backplane for damage. If there is damage to the backplane of the shelf, contact your service representative; 3) Re-insert the Equipment Controller into its original slot and allow the card to initialize; 4) Repeat Step 2) through Step 4) for the second Equipment Controller; 5) Replace the Equipment Controller with the alarm condition with a new unit. If the condition is not cleared, replace the second Equipment Controller with a new unit. Follow the return and repair process to return the faulty card to an authorized repair center for replacement."
],
null
]
}
- Nokia networking MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Nokia support.
Module: TIMETRA-OES-MIB
See published definition above
Module imports
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus', 'TruthValue', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'TIMETRA-TC-MIB': ['TmnxDisplayStringURL', 'TmnxOperState', 'TmnxActionType', 'TNamedItemOrEmpty'], 'INET-ADDRESS-MIB': ['InetAddressPrefixLength', 'InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'TIMETRA-GLOBAL-MIB': ['tmnxSRObjs', 'tmnxSRConfs', 'tmnxSRNotifyPrefix', 'timetraSRMIBModules'], 'TIMETRA-CHASSIS-MIB': ['tmnxHwClass', 'TmnxHwIndexOrZero', 'TmnxDeviceState']}
· Download TIMETRA-OES-MIB
Related source files and packages:
- Netdisco MIB archive copies
· Publisher's source file: timetra-oes-mib.mib
Vendor MIB copy from the Netdisco archive.
Module: TIMETRA-OES-MIB
See published definition above
Module imports
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus', 'TruthValue', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'TIMETRA-TC-MIB': ['TmnxDisplayStringURL', 'TmnxOperState', 'TmnxActionType', 'TNamedItemOrEmpty'], 'INET-ADDRESS-MIB': ['InetAddressPrefixLength', 'InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'TIMETRA-GLOBAL-MIB': ['tmnxSRObjs', 'tmnxSRConfs', 'tmnxSRNotifyPrefix', 'timetraSRMIBModules'], 'TIMETRA-CHASSIS-MIB': ['tmnxHwClass', 'TmnxHwIndexOrZero', 'TmnxDeviceState']}
· Download timetra-oes-mib.mib
Related source files and packages: