Link status failure or critical event.
Sources for this description
Dell MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.674.10892.5.3.2.1.0.2249
Link status failure or critical event.
Identification
{1 3 6 1 4 1 674 10892 5 3 2 1 0 2249}
Available source records contain 2 distinct definitions; some records may not include a definition.
alertLinkStatusFailure NOTIFICATION-TYPE
OBJECTS { alertMessageID,
alertMessage,
alertCurrentStatus,
alertSystemServiceTag,
alertSystemFQDN,
alertFQDD,
alertDeviceDisplayName,
alertMessageArguments,
alertChassisServiceTag,
alertChassisName,
alertRacFQDN }
STATUS current
DESCRIPTION
"Link status failure or critical event."
--#TYPE "System: Link Status Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Device Display Name: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "System Service Tag: %s, System Name: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "RAC FQDN: %s"
--#ARGUMENTS {0, 6, 1, 2, 5, 3, 4, 8, 9, 10}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS current
::= { systemAlertTrapGroup 0 2249 }alertLinkStatusFailure TRAP-TYPE
ENTERPRISE systemAlertTrapGroup
VARIABLES { alertMessageID,
alertMessage,
alertCurrentStatus,
alertSystemServiceTag,
alertSystemFQDN,
alertFQDD,
alertDeviceDisplayName,
alertMessageArguments,
alertChassisServiceTag,
alertChassisName,
alertRacFQDN }
DESCRIPTION
"Link status failure or critical event."
--#TYPE "System: Link Status Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Device Display Name: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "System Service Tag: %s, System Name: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "RAC FQDN: %s"
--#ARGUMENTS {0, 6, 1, 2, 5, 3, 4, 8, 9, 10}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2249
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Link status failure or critical event.
Dell MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: alertLinkStatusFailure
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"alertLinkStatusFailure",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"alertMessageID",
",",
"alertMessage",
",",
"alertCurrentStatus",
",",
"alertSystemServiceTag",
",",
"alertSystemFQDN",
",",
"alertFQDD",
",",
"alertDeviceDisplayName",
",",
"alertMessageArguments",
",",
"alertChassisServiceTag",
",",
"alertChassisName",
",",
"alertRacFQDN",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"Link status failure or critical event.\"",
"::=",
"{",
"systemAlertTrapGroup",
"0",
"2249",
"}"
],
"syntax_tree": [
[
"Objects",
[
"alertMessageID",
"alertMessage",
"alertCurrentStatus",
"alertSystemServiceTag",
"alertSystemFQDN",
"alertFQDD",
"alertDeviceDisplayName",
"alertMessageArguments",
"alertChassisServiceTag",
"alertChassisName",
"alertRacFQDN"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Link status failure or critical event."
],
null
]
}Vendor MIB copy from the LibreNMS archive. Dell support.
Module: IDRAC-MIB-SMIv2
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Vendor MIB copy from the Observium Community archive. Dell support.
Module: IDRAC-MIB-SMIv2
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: IDRAC-MIB-SMIv2
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Status in source: unspecified.
Names: alertLinkStatusFailure
{
"smi_kind": "TRAP-TYPE",
"definition": [
"alertLinkStatusFailure",
"TRAP-TYPE",
"ENTERPRISE",
"systemAlertTrapGroup",
"VARIABLES",
"{",
"alertMessageID",
",",
"alertMessage",
",",
"alertCurrentStatus",
",",
"alertSystemServiceTag",
",",
"alertSystemFQDN",
",",
"alertFQDD",
",",
"alertDeviceDisplayName",
",",
"alertMessageArguments",
",",
"alertChassisServiceTag",
",",
"alertChassisName",
",",
"alertRacFQDN",
"}",
"DESCRIPTION",
"\"Link status failure or critical event.\"",
"::=",
"2249"
],
"syntax_tree": [
[
"objectIdentifier",
[
"systemAlertTrapGroup"
]
],
[
"VarTypes",
[
"alertMessageID",
"alertMessage",
"alertCurrentStatus",
"alertSystemServiceTag",
"alertSystemFQDN",
"alertFQDD",
"alertDeviceDisplayName",
"alertMessageArguments",
"alertChassisServiceTag",
"alertChassisName",
"alertRacFQDN"
]
],
[
"DESCRIPTION",
"Link status failure or critical event."
],
null
]
}Vendor MIB copy from the LibreNMS archive. Dell support.
Module: IDRAC-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}Vendor MIB copy from the Netdisco archive.
Module: IDRAC-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2089 | alertNetworkFailure | 0 | 0 | alertNetworkFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, alertS… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2090 | alertNetworkWarning | 0 | 0 | alertNetworkWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, alertS… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2091 | alertNetworkInformation | 0 | 0 | alertNetworkInformation NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, al… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2153 | alertFanFailure | 0 | 0 | alertFanFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, alertSyste… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2154 | alertFanWarning | 0 | 0 | alertFanWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, alertSyste… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2155 | alertFanInformation | 0 | 0 | alertFanInformation NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, alertS… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2161 | alertTemperatureProbeFailure | 0 | 0 | alertTemperatureProbeFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTa… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2162 | alertTemperatureProbeWarning | 0 | 0 | alertTemperatureProbeWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTa… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2163 | alertTemperatureProbeNormal | 0 | 0 | alertTemperatureProbeNormal NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2169 | alertVoltageProbeFailure | 0 | 0 | alertVoltageProbeFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, a… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2170 | alertVoltageProbeWarning | 0 | 0 | alertVoltageProbeWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, a… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2171 | alertVoltageProbeNormal | 0 | 0 | alertVoltageProbeNormal NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, al… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2177 | alertAmperageProbeFailure | 0 | 0 | alertAmperageProbeFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, … |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2178 | alertAmperageProbeWarning | 0 | 0 | alertAmperageProbeWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, … |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2179 | alertAmperageProbeNormal | 0 | 0 | alertAmperageProbeNormal NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, a… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2185 | alertPowerSupplyFailure | 0 | 0 | alertPowerSupplyFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, al… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2186 | alertPowerSupplyWarning | 0 | 0 | alertPowerSupplyWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, al… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2187 | alertPowerSupplyNormal | 0 | 0 | alertPowerSupplyNormal NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, ale… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2209 | alertIntegratedDualSDModuleFailure | 0 | 0 | alertIntegratedDualSDModuleFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemSer… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2210 | alertIntegratedDualSDModuleWarning | 0 | 0 | alertIntegratedDualSDModuleWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemSer… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2211 | alertIntegratedDualSDModuleInformation | 0 | 0 | alertIntegratedDualSDModuleInformation NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSyste… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2225 | alertBatteryFailure | 0 | 0 | alertBatteryFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, alertS… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2226 | alertBatteryWarning | 0 | 0 | alertBatteryWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, alertS… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2227 | alertBatteryNormal | 0 | 0 | alertBatteryNormal NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, alertSy… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2233 | alertAutomaticSystemRecovery | 0 | 0 | alertAutomaticSystemRecovery NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTa… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2241 | alertProcessorDeviceStatusFailure | 0 | 0 | alertProcessorDeviceStatusFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServ… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2242 | alertProcessorDeviceStatusWarning | 0 | 0 | alertProcessorDeviceStatusWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServ… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2243 | alertProcessorDeviceStatusNormal | 0 | 0 | alertProcessorDeviceStatusNormal NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServi… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2250 | alertLinkStatusWarning | 0 | 0 | |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2251 | alertLinkStatusInformation | 0 | 0 | |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2265 | alertMemoryDeviceFailure | 0 | 0 | alertMemoryDeviceFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, a… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2266 | alertMemoryDeviceWarning | 0 | 0 | alertMemoryDeviceWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, a… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2267 | alertMemoryDeviceInformation | 0 | 0 | alertMemoryDeviceInformation NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTa… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2273 | alertPowerUsageFailure | 0 | 0 | alertPowerUsageFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, ale… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2274 | alertPowerUsageWarning | 0 | 0 | alertPowerUsageWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, ale… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2275 | alertPowerUsageInformation | 0 | 0 | alertPowerUsageInformation NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, … |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2297 | alertPhysicalDiskFailure | 0 | 0 | alertPhysicalDiskFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, a… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2298 | alertPhysicalDiskWarning | 0 | 0 | alertPhysicalDiskWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, a… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2299 | alertPhysicalDiskInformation | 0 | 0 | alertPhysicalDiskInformation NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTa… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2329 | alertHardwareConfigurationFailure | 0 | 0 | alertHardwareConfigurationFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServ… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2330 | alertHardwareConfigurationWarning | 0 | 0 | alertHardwareConfigurationWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServ… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2331 | alertHardwareConfigurationInformation | 0 | 0 | alertHardwareConfigurationInformation NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystem… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2337 | alertSoftwareConfigurationFailure | 0 | 0 | |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2338 | alertSoftwareConfigurationWarning | 0 | 0 | |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2339 | alertSoftwareConfigurationInformation | 0 | 0 | |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2377 | alertSystemEventLogFailure | 0 | 0 | alertSystemEventLogFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, … |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2378 | alertSystemEventLogWarning | 0 | 0 | alertSystemEventLogWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, … |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2379 | alertSystemEventLogInformation | 0 | 0 | alertSystemEventLogInformation NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemService… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2385 | alertSecurityFailure | 0 | 0 | alertSecurityFailure NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, alert… |
| 1.3.6.1.4.1.674.10892.5.3.2.1.0.2386 | alertSecurityWarning | 0 | 0 |