OID reference

coolingDeviceReading

1.3.6.1.4.1.674.10892.555.4.700.12.1.6

Description

0700.0012.0001.0006 This attribute defines the reading for a cooling device of subtype other than coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device. Wh…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.674.10892.555.4.700.12.1 (coolingDeviceTableEntry)
Node code
6
Node name
coolingDeviceReading
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.674.10892.555.4.700.12.1.6
URN notation
urn:oid:1.3.6.1.4.1.674.10892.555.4.700.12.1.6
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 674 10892 555 4 700 12 1 6}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dell(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dellEnterprise(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dell(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dellEnterprise(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dell(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dellEnterprise(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dell(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dellEnterprise(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) dell(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) dellEnterprise(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dell(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dellEnterprise(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) dell(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) dellEnterprise(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) dell(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) dellEnterprise(674) server3(10892) outOfBandGroup(555) systemDetailsGroup(4) thermalGroup(700) coolingDeviceTable(12) coolingDeviceTableEntry(1) coolingDeviceReading(6)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/674/10892/555/4/700/12/1/6
  • /ISO/Identified-Organization/6/1/4/1/674/10892/555/4/700/12/1/6
  • /ISO/3/6/1/4/1/674/10892/555/4/700/12/1/6
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/dell/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/identified-organization/dod/internet/private/enterprise/dellEnterprise/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/identified-organization/dod/internet/private/enterprises/dell/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/identified-organization/dod/internet/private/enterprises/dellEnterprise/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/dell/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/dellEnterprise/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/identified-organization/dod/internet/private/vendor-objects/dell/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/identified-organization/dod/internet/private/vendor-objects/dellEnterprise/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/org/dod/internet/private/enterprise/dell/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/org/dod/internet/private/enterprise/dellEnterprise/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/org/dod/internet/private/enterprises/dell/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/org/dod/internet/private/enterprises/dellEnterprise/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/org/dod/internet/private/ldap-enterprise/dell/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/org/dod/internet/private/ldap-enterprise/dellEnterprise/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/org/dod/internet/private/vendor-objects/dell/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • /iso/org/dod/internet/private/vendor-objects/dellEnterprise/server3/outOfBandGroup/systemDetailsGroup/thermalGroup/coolingDeviceTable/coolingDeviceTableEntry/coolingDeviceReading
  • Additional combinations skipped.

SNMP properties

Value type
Signed32BitRange
Maximum access defined by MIB
read-only
Status in MIB
mandatory

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

coolingDeviceReading                            OBJECT-TYPE
    SYNTAX      Signed32BitRange
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "0700.0012.0001.0006 This attribute defines the reading for a cooling device
        of subtype other than coolingDeviceSubTypeIsDiscrete.  When the value
        for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the
        value returned for this attribute is the speed in RPM or the OFF/ON value
        of the cooling device.  When the value for coolingDeviceSubType is
        coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute."
    ::= { coolingDeviceTableEntry 6 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

0700.0012.0001.0006 This attribute defines the reading for a cooling device of subtype other than coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute.

Sources for this description

Dell MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Dell MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

coolingDeviceReading · mandatoryDell MIB copies (LibreNMS/Observium Community)1 source

Status in source: mandatory.

Names: coolingDeviceReading

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "coolingDeviceReading",
    "OBJECT-TYPE",
    "SYNTAX",
    "Signed32BitRange",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"0700.0012.0001.0006 This attribute defines the reading for a cooling device of subtype other than coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute.\"",
    "::=",
    "{",
    "coolingDeviceTableEntry",
    "6",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "Signed32BitRange"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "0700.0012.0001.0006 This attribute defines the reading for a cooling device of subtype other than coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.674)

Wood Eric

Siblings (18)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.674.10892.555.4.700.12.1.1 coolingDevicechassisIndex00
1.3.6.1.4.1.674.10892.555.4.700.12.1.2 coolingDeviceIndex00
1.3.6.1.4.1.674.10892.555.4.700.12.1.3 coolingDeviceStateCapabilities00
1.3.6.1.4.1.674.10892.555.4.700.12.1.4 coolingDeviceStateSettings00
1.3.6.1.4.1.674.10892.555.4.700.12.1.5 coolingDeviceStatus00
1.3.6.1.4.1.674.10892.555.4.700.12.1.7 coolingDeviceType00
1.3.6.1.4.1.674.10892.555.4.700.12.1.8 coolingDeviceLocationName00
1.3.6.1.4.1.674.10892.555.4.700.12.1.9 coolingDeviceUpperNonRecoverableThreshold00
1.3.6.1.4.1.674.10892.555.4.700.12.1.10 coolingDeviceUpperCriticalThreshold00
1.3.6.1.4.1.674.10892.555.4.700.12.1.11 coolingDeviceUpperNonCriticalThreshold00
1.3.6.1.4.1.674.10892.555.4.700.12.1.12 coolingDeviceLowerNonCriticalThreshold00
1.3.6.1.4.1.674.10892.555.4.700.12.1.13 coolingDeviceLowerCriticalThreshold00
1.3.6.1.4.1.674.10892.555.4.700.12.1.14 coolingDeviceLowerNonRecoverableThreshold00
1.3.6.1.4.1.674.10892.555.4.700.12.1.15 coolingDevicecoolingUnitIndexReference00
1.3.6.1.4.1.674.10892.555.4.700.12.1.16 coolingDeviceSubType00
1.3.6.1.4.1.674.10892.555.4.700.12.1.17 coolingDeviceProbeCapabilities00
1.3.6.1.4.1.674.10892.555.4.700.12.1.18 coolingDeviceDiscreteReading00
1.3.6.1.4.1.674.10892.555.4.700.12.1.19 coolingDeviceFQDD00