The two notifications which an SNMPv2 entity is required to implement.
Sources for this description
Dell MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.674.10892.6.10.2.3
The two notifications which an SNMPv2 entity is required to implement.
Identification
{1 3 6 1 4 1 674 10892 6 10 2 3}
The displayed source records contain one distinct definition. Compare its source records.
dmmiDRACAlertNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { iDRAC10267alertJobControlConfigurationInformation, iDRAC10298alertPRDeviceDetectionWarning, iDRAC10395alertTestTrapEvent, iDRAC10529alertSWCConfigurationFailure, iDRAC10530alertSWCConfigurationWarning, iDRAC10531alertSWCConfigurationInformation, iDRAC10547alertIPAddressConfigurationInformation, iDRAC10578alertSecurityConfigurationWarning, iDRAC10611alertPCIDeviceConfigurationInformation, iDRAC10627alertSystemConfigurationChangeInformation, iDRAC10635alertAutoDiscoveryInformation, iDRAC10770alertNetworkConfigurationWarning, iDRAC10771alertNetworkConfigurationInformation, iDRAC11274alertSDKConfigurationWarning, iDRAC11275alertSDKConfigurationInformation, iDRAC2089alertNetworkFailure, iDRAC2090alertNetworkWarning, iDRAC2091alertNetworkInformation, iDRAC2153alertFanFailure, iDRAC2154alertFanWarning, iDRAC2155alertFanInformation, iDRAC2161alertTemperatureProbeFailure, iDRAC2162alertTemperatureProbeWarning, iDRAC2163alertTemperatureProbeNormal, iDRAC2169alertVoltageProbeFailure, iDRAC2170alertVoltageProbeWarning, iDRAC2171alertVoltageProbeNormal, iDRAC2177alertAmperageProbeFailure, iDRAC2178alertAmperageProbeWarning, iDRAC2179alertAmperageProbeNormal, iDRAC2185alertPowerSupplyFailure, iDRAC2186alertPowerSupplyWarning, iDRAC2187alertPowerSupplyNormal, iDRAC2209alertIntegratedDualSDModuleFailure, iDRAC2210alertIntegratedDualSDModuleWarning, iDRAC2211alertIntegratedDualSDModuleInformation, iDRAC2225alertBatteryFailure, iDRAC2226alertBatteryWarning, iDRAC2227alertBatteryNormal, iDRAC2233alertAutomaticSystemRecovery, iDRAC2241alertProcessorDeviceStatusFailure, iDRAC2242alertProcessorDeviceStatusWarning, iDRAC2243alertProcessorDeviceStatusNormal, iDRAC2249alertLinkStatusFailure, iDRAC2250alertLinkStatusWarning, iDRAC2251alertLinkStatusInformation, iDRAC2265alertMemoryDeviceFailure, iDRAC2266alertMemoryDeviceWarning, iDRAC2267alertMemoryDeviceInformation, iDRAC2273alertPowerUsageFailure, iDRAC2274alertPowerUsageWarning, iDRAC2275alertPowerUsageInformation, iDRAC2297alertPhysicalDiskFailure, iDRAC2298alertPhysicalDiskWarning, iDRAC2299alertPhysicalDiskInformation, iDRAC2329alertHardwareConfigurationFailure, iDRAC2330alertHardwareConfigurationWarning, iDRAC2331alertHardwareConfigurationInformation, iDRAC2337alertSoftwareConfigurationFailure, iDRAC2338alertSoftwareConfigurationWarning, iDRAC2339alertSoftwareConfigurationInformation, iDRAC2377alertSystemEventLogFailure, iDRAC2378alertSystemEventLogWarning, iDRAC2379alertSystemEventLogInformation, iDRAC2385alertSecurityFailure, iDRAC2386alertSecurityWarning, iDRAC2387alertSecurityInformation, iDRAC2393alertCableFailure, iDRAC2409alertOSFailure, iDRAC2411alertOSInformation, iDRAC2417alertPCIDeviceFailure, iDRAC2418alertPCIDeviceWarning, iDRAC2419alertPCIDeviceInformation, iDRAC2425alertBiosPostFailure, iDRAC2433alertInternaliDRACMemoryUnresponsive, iDRAC2435alertServerIdleTime, iDRAC2457alertProcessorDeviceAbsent, iDRAC2465alertPowerSupplyAbsent, iDRAC2473alertRedundancyLost, iDRAC2474alertRedundancyDegraded, iDRAC2475alertRedundancyInformation, iDRAC2481alertIntegratedDualSDModuleAbsent, iDRAC2489alertIntegratedDualSDModuleRedundancyLost, iDRAC2490alertIntegratedDualSDModuleRedundancyDegraded, iDRAC2491alertIntegratedDualSDModuleRedundancyInformation, iDRAC2505alertvFlashMediaDeviceFailure, iDRAC2506alertvFlashMediaDeviceWarning, iDRAC2507alertvFlashMediaDeviceInformation, iDRAC2515alertvFlashMediaDeviceAbsent, iDRAC2521alertTemperatureStatisticsFailure, iDRAC2522alertTemperatureStatisticsWarning, iDRAC2531alertRACInformation, iDRAC2537alertFiberChannelFailure, iDRAC2538alertFiberChannelWarning, iDRAC2539alertFiberChannelInformation, iDRAC2545alertCMCFailure, iDRAC2546alertCMCWarning, iDRAC2553alertIOVirtualizationFailure, iDRAC2650alertSystemPerformanceWarning, iDRAC3049alertLiquidCoolingLeakFailure, iDRAC3050alertLiquidCoolingLeakWarning, iDRAC3051alertLiquidCoolingLeakInformational, iDRAC3082alertSDKSystemWarning, iDRAC3083alertSDKSystemInformational, iDRAC4177alertStorageManagementFailure, iDRAC4178alertStorageManagementWarning, iDRAC4179alertStorageManagementInformation, iDRAC4201alertStorageFanFailure, iDRAC4202alertStorageFanWarning, iDRAC4203alertStorageFanInformation, iDRAC4209alertStorageTemperatureProbeFailure, iDRAC4210alertStorageTemperatureProbeWarning, iDRAC4211alertStorageTemperatureProbeInformation, iDRAC4233alertStoragePowerSupplyFailure, iDRAC4234alertStoragePowerSupplyWarning, iDRAC4235alertStoragePowerSupplyInformation, iDRAC4273alertStorageBatteryFailure, iDRAC4274alertStorageBatteryWarning, iDRAC4275alertStorageBatteryInformation, iDRAC4329alertStorageControllerFailure, iDRAC4330alertStorageControllerWarning, iDRAC4331alertStorageControllerInformation, iDRAC4337alertStorageEnclosureFailure, iDRAC4338alertStorageEnclosureWarning, iDRAC4339alertStorageEnclosureInformation, iDRAC4345alertStoragePhysicalDiskFailure, iDRAC4346alertStoragePhysicalDiskWarning, iDRAC4347alertStoragePhysicalDiskInformation, iDRAC4353alertStorageVirtualDiskFailure, iDRAC4354alertStorageVirtualDiskWarning, iDRAC4355alertStorageVirtualDiskInformation, iDRAC4370alertStorageSolidstateDrive, iDRAC4433alertStorageSecurityFailure, iDRAC4434alertStorageSecurityWarning, iDRAC4435alertStorageSecurityInformation, iDRAC4761alertStorageSoftwareDefinedSubSystemFailure, iDRAC4762alertStorageSoftwareDefinedSubSystemWarning, iDRAC6211alertUpdateJobInformation, iDRAC6314alertSoftwareChangeUpdateWarning, iDRAC8305alertTemperatureProbeChangeFailure, iDRAC8306alertTemperatureProbeReadWarning, iDRAC8329alertPowerSupplyAuditFailure, iDRAC8330alertPowerSupplyAuditWarning, iDRAC8417alertPowerUsageAuditFailure, iDRAC8418alertPowerUsageAuditWarning, iDRAC8419alertPowerUsageAuditInformation, iDRAC8474alertHWCAuditWarning, iDRAC8475alertHWCAuditInformation, iDRAC8490alertUserTrackingWarning, iDRAC8499alertiDRACIPAddressChange, iDRAC8513alertLicenseFailure, iDRAC8514alertLicenseWarning, iDRAC8515alertLicenseInformation, iDRAC8562alertPCIDeviceAuditWarning, iDRAC8579alertSystemPowerStateChangeInformation, iDRAC8594alertDebugWarning, iDRAC8595alertDebugInformation, iDRAC8674alertRacConfigurationChangewarning, iDRAC8675alertRacConfigurationChangeInformation, iDRAC8689alertCMCAuditFailure, iDRAC8690alertCMCAuditWarning, iDRAC8691alertCMCAuditInformation }
STATUS current
DESCRIPTION
"The two notifications which an SNMPv2 entity is required to
implement."
::= { conformanceMIBnotificationGroup 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The two notifications which an SNMPv2 entity is required to implement.
Dell MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: dmmiDRACAlertNotificationGroup
{
"smi_kind": "NOTIFICATION-GROUP",
"definition": [
"dmmiDRACAlertNotificationGroup",
"NOTIFICATION-GROUP",
"NOTIFICATIONS",
"{",
"iDRAC10267alertJobControlConfigurationInformation",
",",
"iDRAC10298alertPRDeviceDetectionWarning",
",",
"iDRAC10395alertTestTrapEvent",
",",
"iDRAC10529alertSWCConfigurationFailure",
",",
"iDRAC10530alertSWCConfigurationWarning",
",",
"iDRAC10531alertSWCConfigurationInformation",
",",
"iDRAC10547alertIPAddressConfigurationInformation",
",",
"iDRAC10578alertSecurityConfigurationWarning",
",",
"iDRAC10611alertPCIDeviceConfigurationInformation",
",",
"iDRAC10627alertSystemConfigurationChangeInformation",
",",
"iDRAC10635alertAutoDiscoveryInformation",
",",
"iDRAC10770alertNetworkConfigurationWarning",
",",
"iDRAC10771alertNetworkConfigurationInformation",
",",
"iDRAC11274alertSDKConfigurationWarning",
",",
"iDRAC11275alertSDKConfigurationInformation",
",",
"iDRAC2089alertNetworkFailure",
",",
"iDRAC2090alertNetworkWarning",
",",
"iDRAC2091alertNetworkInformation",
",",
"iDRAC2153alertFanFailure",
",",
"iDRAC2154alertFanWarning",
",",
"iDRAC2155alertFanInformation",
",",
"iDRAC2161alertTemperatureProbeFailure",
",",
"iDRAC2162alertTemperatureProbeWarning",
",",
"iDRAC2163alertTemperatureProbeNormal",
",",
"iDRAC2169alertVoltageProbeFailure",
",",
"iDRAC2170alertVoltageProbeWarning",
",",
"iDRAC2171alertVoltageProbeNormal",
",",
"iDRAC2177alertAmperageProbeFailure",
",",
"iDRAC2178alertAmperageProbeWarning",
",",
"iDRAC2179alertAmperageProbeNormal",
",",
"iDRAC2185alertPowerSupplyFailure",
",",
"iDRAC2186alertPowerSupplyWarning",
",",
"iDRAC2187alertPowerSupplyNormal",
",",
"iDRAC2209alertIntegratedDualSDModuleFailure",
",",
"iDRAC2210alertIntegratedDualSDModuleWarning",
",",
"iDRAC2211alertIntegratedDualSDModuleInformation",
",",
"iDRAC2225alertBatteryFailure",
",",
"iDRAC2226alertBatteryWarning",
",",
"iDRAC2227alertBatteryNormal",
",",
"iDRAC2233alertAutomaticSystemRecovery",
",",
"iDRAC2241alertProcessorDeviceStatusFailure",
",",
"iDRAC2242alertProcessorDeviceStatusWarning",
",",
"iDRAC2243alertProcessorDeviceStatusNormal",
",",
"iDRAC2249alertLinkStatusFailure",
",",
"iDRAC2250alertLinkStatusWarning",
",",
"iDRAC2251alertLinkStatusInformation",
",",
"iDRAC2265alertMemoryDeviceFailure",
",",
"iDRAC2266alertMemoryDeviceWarning",
",",
"iDRAC2267alertMemoryDeviceInformation",
",",
"iDRAC2273alertPowerUsageFailure",
",",
"iDRAC2274alertPowerUsageWarning",
",",
"iDRAC2275alertPowerUsageInformation",
",",
"iDRAC2297alertPhysicalDiskFailure",
",",
"iDRAC2298alertPhysicalDiskWarning",
",",
"iDRAC2299alertPhysicalDiskInformation",
",",
"iDRAC2329alertHardwareConfigurationFailure",
",",
"iDRAC2330alertHardwareConfigurationWarning",
",",
"iDRAC2331alertHardwareConfigurationInformation",
",",
"iDRAC2337alertSoftwareConfigurationFailure",
",",
"iDRAC2338alertSoftwareConfigurationWarning",
",",
"iDRAC2339alertSoftwareConfigurationInformation",
",",
"iDRAC2377alertSystemEventLogFailure",
",",
"iDRAC2378alertSystemEventLogWarning",
",",
"iDRAC2379alertSystemEventLogInformation",
",",
"iDRAC2385alertSecurityFailure",
",",
"iDRAC2386alertSecurityWarning",
",",
"iDRAC2387alertSecurityInformation",
",",
"iDRAC2393alertCableFailure",
",",
"iDRAC2409alertOSFailure",
",",
"iDRAC2411alertOSInformation",
",",
"iDRAC2417alertPCIDeviceFailure",
",",
"iDRAC2418alertPCIDeviceWarning",
",",
"iDRAC2419alertPCIDeviceInformation",
",",
"iDRAC2425alertBiosPostFailure",
",",
"iDRAC2433alertInternaliDRACMemoryUnresponsive",
",",
"iDRAC2435alertServerIdleTime",
",",
"iDRAC2457alertProcessorDeviceAbsent",
",",
"iDRAC2465alertPowerSupplyAbsent",
",",
"iDRAC2473alertRedundancyLost",
",",
"iDRAC2474alertRedundancyDegraded",
",",
"iDRAC2475alertRedundancyInformation",
",",
"iDRAC2481alertIntegratedDualSDModuleAbsent",
",",
"iDRAC2489alertIntegratedDualSDModuleRedundancyLost",
",",
"iDRAC2490alertIntegratedDualSDModuleRedundancyDegraded",
",",
"iDRAC2491alertIntegratedDualSDModuleRedundancyInformation",
",",
"iDRAC2505alertvFlashMediaDeviceFailure",
",",
"iDRAC2506alertvFlashMediaDeviceWarning",
",",
"iDRAC2507alertvFlashMediaDeviceInformation",
",",
"iDRAC2515alertvFlashMediaDeviceAbsent",
",",
"iDRAC2521alertTemperatureStatisticsFailure",
",",
"iDRAC2522alertTemperatureStatisticsWarning",
",",
"iDRAC2531alertRACInformation",
",",
"iDRAC2537alertFiberChannelFailure",
",",
"iDRAC2538alertFiberChannelWarning",
",",
"iDRAC2539alertFiberChannelInformation",
",",
"iDRAC2545alertCMCFailure",
",",
"iDRAC2546alertCMCWarning",
",",
"iDRAC2553alertIOVirtualizationFailure",
",",
"iDRAC2650alertSystemPerformanceWarning",
",",
"iDRAC3049alertLiquidCoolingLeakFailure",
",",
"iDRAC3050alertLiquidCoolingLeakWarning",
",",
"iDRAC3051alertLiquidCoolingLeakInformational",
",",
"iDRAC3082alertSDKSystemWarning",
",",
"iDRAC3083alertSDKSystemInformational",
",",
"iDRAC4177alertStorageManagementFailure",
",",
"iDRAC4178alertStorageManagementWarning",
",",
"iDRAC4179alertStorageManagementInformation",
",",
"iDRAC4201alertStorageFanFailure",
",",
"iDRAC4202alertStorageFanWarning",
",",
"iDRAC4203alertStorageFanInformation",
",",
"iDRAC4209alertStorageTemperatureProbeFailure",
",",
"iDRAC4210alertStorageTemperatureProbeWarning",
",",
"iDRAC4211alertStorageTemperatureProbeInformation",
",",
"iDRAC4233alertStoragePowerSupplyFailure",
",",
"iDRAC4234alertStoragePowerSupplyWarning",
",",
"iDRAC4235alertStoragePowerSupplyInformation",
",",
"iDRAC4273alertStorageBatteryFailure",
",",
"iDRAC4274alertStorageBatteryWarning",
",",
"iDRAC4275alertStorageBatteryInformation",
",",
"iDRAC4329alertStorageControllerFailure",
",",
"iDRAC4330alertStorageControllerWarning",
",",
"iDRAC4331alertStorageControllerInformation",
",",
"iDRAC4337alertStorageEnclosureFailure",
",",
"iDRAC4338alertStorageEnclosureWarning",
",",
"iDRAC4339alertStorageEnclosureInformation",
",",
"iDRAC4345alertStoragePhysicalDiskFailure",
",",
"iDRAC4346alertStoragePhysicalDiskWarning",
",",
"iDRAC4347alertStoragePhysicalDiskInformation",
",",
"iDRAC4353alertStorageVirtualDiskFailure",
",",
"iDRAC4354alertStorageVirtualDiskWarning",
",",
"iDRAC4355alertStorageVirtualDiskInformation",
",",
"iDRAC4370alertStorageSolidstateDrive",
",",
"iDRAC4433alertStorageSecurityFailure",
",",
"iDRAC4434alertStorageSecurityWarning",
",",
"iDRAC4435alertStorageSecurityInformation",
",",
"iDRAC4761alertStorageSoftwareDefinedSubSystemFailure",
",",
"iDRAC4762alertStorageSoftwareDefinedSubSystemWarning",
",",
"iDRAC6211alertUpdateJobInformation",
",",
"iDRAC6314alertSoftwareChangeUpdateWarning",
",",
"iDRAC8305alertTemperatureProbeChangeFailure",
",",
"iDRAC8306alertTemperatureProbeReadWarning",
",",
"iDRAC8329alertPowerSupplyAuditFailure",
",",
"iDRAC8330alertPowerSupplyAuditWarning",
",",
"iDRAC8417alertPowerUsageAuditFailure",
",",
"iDRAC8418alertPowerUsageAuditWarning",
",",
"iDRAC8419alertPowerUsageAuditInformation",
",",
"iDRAC8474alertHWCAuditWarning",
",",
"iDRAC8475alertHWCAuditInformation",
",",
"iDRAC8490alertUserTrackingWarning",
",",
"iDRAC8499alertiDRACIPAddressChange",
",",
"iDRAC8513alertLicenseFailure",
",",
"iDRAC8514alertLicenseWarning",
",",
"iDRAC8515alertLicenseInformation",
",",
"iDRAC8562alertPCIDeviceAuditWarning",
",",
"iDRAC8579alertSystemPowerStateChangeInformation",
",",
"iDRAC8594alertDebugWarning",
",",
"iDRAC8595alertDebugInformation",
",",
"iDRAC8674alertRacConfigurationChangewarning",
",",
"iDRAC8675alertRacConfigurationChangeInformation",
",",
"iDRAC8689alertCMCAuditFailure",
",",
"iDRAC8690alertCMCAuditWarning",
",",
"iDRAC8691alertCMCAuditInformation",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"The two notifications which an SNMPv2 entity is required to implement.\"",
"::=",
"{",
"conformanceMIBnotificationGroup",
"3",
"}"
],
"syntax_tree": [
[
"Notifications",
[
"iDRAC10267alertJobControlConfigurationInformation",
"iDRAC10298alertPRDeviceDetectionWarning",
"iDRAC10395alertTestTrapEvent",
"iDRAC10529alertSWCConfigurationFailure",
"iDRAC10530alertSWCConfigurationWarning",
"iDRAC10531alertSWCConfigurationInformation",
"iDRAC10547alertIPAddressConfigurationInformation",
"iDRAC10578alertSecurityConfigurationWarning",
"iDRAC10611alertPCIDeviceConfigurationInformation",
"iDRAC10627alertSystemConfigurationChangeInformation",
"iDRAC10635alertAutoDiscoveryInformation",
"iDRAC10770alertNetworkConfigurationWarning",
"iDRAC10771alertNetworkConfigurationInformation",
"iDRAC11274alertSDKConfigurationWarning",
"iDRAC11275alertSDKConfigurationInformation",
"iDRAC2089alertNetworkFailure",
"iDRAC2090alertNetworkWarning",
"iDRAC2091alertNetworkInformation",
"iDRAC2153alertFanFailure",
"iDRAC2154alertFanWarning",
"iDRAC2155alertFanInformation",
"iDRAC2161alertTemperatureProbeFailure",
"iDRAC2162alertTemperatureProbeWarning",
"iDRAC2163alertTemperatureProbeNormal",
"iDRAC2169alertVoltageProbeFailure",
"iDRAC2170alertVoltageProbeWarning",
"iDRAC2171alertVoltageProbeNormal",
"iDRAC2177alertAmperageProbeFailure",
"iDRAC2178alertAmperageProbeWarning",
"iDRAC2179alertAmperageProbeNormal",
"iDRAC2185alertPowerSupplyFailure",
"iDRAC2186alertPowerSupplyWarning",
"iDRAC2187alertPowerSupplyNormal",
"iDRAC2209alertIntegratedDualSDModuleFailure",
"iDRAC2210alertIntegratedDualSDModuleWarning",
"iDRAC2211alertIntegratedDualSDModuleInformation",
"iDRAC2225alertBatteryFailure",
"iDRAC2226alertBatteryWarning",
"iDRAC2227alertBatteryNormal",
"iDRAC2233alertAutomaticSystemRecovery",
"iDRAC2241alertProcessorDeviceStatusFailure",
"iDRAC2242alertProcessorDeviceStatusWarning",
"iDRAC2243alertProcessorDeviceStatusNormal",
"iDRAC2249alertLinkStatusFailure",
"iDRAC2250alertLinkStatusWarning",
"iDRAC2251alertLinkStatusInformation",
"iDRAC2265alertMemoryDeviceFailure",
"iDRAC2266alertMemoryDeviceWarning",
"iDRAC2267alertMemoryDeviceInformation",
"iDRAC2273alertPowerUsageFailure",
"iDRAC2274alertPowerUsageWarning",
"iDRAC2275alertPowerUsageInformation",
"iDRAC2297alertPhysicalDiskFailure",
"iDRAC2298alertPhysicalDiskWarning",
"iDRAC2299alertPhysicalDiskInformation",
"iDRAC2329alertHardwareConfigurationFailure",
"iDRAC2330alertHardwareConfigurationWarning",
"iDRAC2331alertHardwareConfigurationInformation",
"iDRAC2337alertSoftwareConfigurationFailure",
"iDRAC2338alertSoftwareConfigurationWarning",
"iDRAC2339alertSoftwareConfigurationInformation",
"iDRAC2377alertSystemEventLogFailure",
"iDRAC2378alertSystemEventLogWarning",
"iDRAC2379alertSystemEventLogInformation",
"iDRAC2385alertSecurityFailure",
"iDRAC2386alertSecurityWarning",
"iDRAC2387alertSecurityInformation",
"iDRAC2393alertCableFailure",
"iDRAC2409alertOSFailure",
"iDRAC2411alertOSInformation",
"iDRAC2417alertPCIDeviceFailure",
"iDRAC2418alertPCIDeviceWarning",
"iDRAC2419alertPCIDeviceInformation",
"iDRAC2425alertBiosPostFailure",
"iDRAC2433alertInternaliDRACMemoryUnresponsive",
"iDRAC2435alertServerIdleTime",
"iDRAC2457alertProcessorDeviceAbsent",
"iDRAC2465alertPowerSupplyAbsent",
"iDRAC2473alertRedundancyLost",
"iDRAC2474alertRedundancyDegraded",
"iDRAC2475alertRedundancyInformation",
"iDRAC2481alertIntegratedDualSDModuleAbsent",
"iDRAC2489alertIntegratedDualSDModuleRedundancyLost",
"iDRAC2490alertIntegratedDualSDModuleRedundancyDegraded",
"iDRAC2491alertIntegratedDualSDModuleRedundancyInformation",
"iDRAC2505alertvFlashMediaDeviceFailure",
"iDRAC2506alertvFlashMediaDeviceWarning",
"iDRAC2507alertvFlashMediaDeviceInformation",
"iDRAC2515alertvFlashMediaDeviceAbsent",
"iDRAC2521alertTemperatureStatisticsFailure",
"iDRAC2522alertTemperatureStatisticsWarning",
"iDRAC2531alertRACInformation",
"iDRAC2537alertFiberChannelFailure",
"iDRAC2538alertFiberChannelWarning",
"iDRAC2539alertFiberChannelInformation",
"iDRAC2545alertCMCFailure",
"iDRAC2546alertCMCWarning",
"iDRAC2553alertIOVirtualizationFailure",
"iDRAC2650alertSystemPerformanceWarning",
"iDRAC3049alertLiquidCoolingLeakFailure",
"iDRAC3050alertLiquidCoolingLeakWarning",
"iDRAC3051alertLiquidCoolingLeakInformational",
"iDRAC3082alertSDKSystemWarning",
"iDRAC3083alertSDKSystemInformational",
"iDRAC4177alertStorageManagementFailure",
"iDRAC4178alertStorageManagementWarning",
"iDRAC4179alertStorageManagementInformation",
"iDRAC4201alertStorageFanFailure",
"iDRAC4202alertStorageFanWarning",
"iDRAC4203alertStorageFanInformation",
"iDRAC4209alertStorageTemperatureProbeFailure",
"iDRAC4210alertStorageTemperatureProbeWarning",
"iDRAC4211alertStorageTemperatureProbeInformation",
"iDRAC4233alertStoragePowerSupplyFailure",
"iDRAC4234alertStoragePowerSupplyWarning",
"iDRAC4235alertStoragePowerSupplyInformation",
"iDRAC4273alertStorageBatteryFailure",
"iDRAC4274alertStorageBatteryWarning",
"iDRAC4275alertStorageBatteryInformation",
"iDRAC4329alertStorageControllerFailure",
"iDRAC4330alertStorageControllerWarning",
"iDRAC4331alertStorageControllerInformation",
"iDRAC4337alertStorageEnclosureFailure",
"iDRAC4338alertStorageEnclosureWarning",
"iDRAC4339alertStorageEnclosureInformation",
"iDRAC4345alertStoragePhysicalDiskFailure",
"iDRAC4346alertStoragePhysicalDiskWarning",
"iDRAC4347alertStoragePhysicalDiskInformation",
"iDRAC4353alertStorageVirtualDiskFailure",
"iDRAC4354alertStorageVirtualDiskWarning",
"iDRAC4355alertStorageVirtualDiskInformation",
"iDRAC4370alertStorageSolidstateDrive",
"iDRAC4433alertStorageSecurityFailure",
"iDRAC4434alertStorageSecurityWarning",
"iDRAC4435alertStorageSecurityInformation",
"iDRAC4761alertStorageSoftwareDefinedSubSystemFailure",
"iDRAC4762alertStorageSoftwareDefinedSubSystemWarning",
"iDRAC6211alertUpdateJobInformation",
"iDRAC6314alertSoftwareChangeUpdateWarning",
"iDRAC8305alertTemperatureProbeChangeFailure",
"iDRAC8306alertTemperatureProbeReadWarning",
"iDRAC8329alertPowerSupplyAuditFailure",
"iDRAC8330alertPowerSupplyAuditWarning",
"iDRAC8417alertPowerUsageAuditFailure",
"iDRAC8418alertPowerUsageAuditWarning",
"iDRAC8419alertPowerUsageAuditInformation",
"iDRAC8474alertHWCAuditWarning",
"iDRAC8475alertHWCAuditInformation",
"iDRAC8490alertUserTrackingWarning",
"iDRAC8499alertiDRACIPAddressChange",
"iDRAC8513alertLicenseFailure",
"iDRAC8514alertLicenseWarning",
"iDRAC8515alertLicenseInformation",
"iDRAC8562alertPCIDeviceAuditWarning",
"iDRAC8579alertSystemPowerStateChangeInformation",
"iDRAC8594alertDebugWarning",
"iDRAC8595alertDebugInformation",
"iDRAC8674alertRacConfigurationChangewarning",
"iDRAC8675alertRacConfigurationChangeInformation",
"iDRAC8689alertCMCAuditFailure",
"iDRAC8690alertCMCAuditWarning",
"iDRAC8691alertCMCAuditInformation"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The two notifications which an SNMPv2 entity is required to implement."
],
null
]
}Vendor MIB copy from the LibreNMS archive. Dell support.
Module: DELL-MM-MIB-SMIv2
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.674.10892.6.10.2.1 | dmmChassisAlert2NotificationGroup | 0 | 0 | |
| 1.3.6.1.4.1.674.10892.6.10.2.2 | dmmGenericAlertNotificationGroup | 0 | 0 | |
| 1.3.6.1.4.1.674.10892.6.10.2.4 | dmmNWIOMAlertNotificationGroup | 0 | 0 | |
| 1.3.6.1.4.1.674.10892.6.10.2.5 | dmmSASIOMAlertNotificationGroup | 0 | 0 |