Description 1
The type of temperature sensor
Sources for this description
Dell MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.3
The type of temperature sensor
Identification
{1 3 6 1 4 1 674 10895 5000 2 6132 1 1 43 1 9 1 3}
Definitions may combine these properties differently.
Numbers refer to source variants above. Each value is shown only for variants that define it.
| Value | Name | Source variants |
|---|---|---|
| 1 | fixed | 1 |
| 2 | removable | 1 |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In DNOS-BOXSERVICES-PRIVATE-MIB, the row index consists of these components in order:
boxsPwrUsageHistoryUnitIndex (INTEGER): one numeric subidentifier for the non-negative value.boxsPwrUsageHistoryUnitSampleIndex (INTEGER): one numeric subidentifier for the non-negative value.An instance has the form .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.3.<boxsPwrUsageHistoryUnitIndex>.<boxsPwrUsageHistoryUnitSampleIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.
Published row index variants: boxServicesUnitIndex, boxServicesStackTempSensorIndex; boxsPwrUsageHistoryUnitIndex, boxsPwrUsageHistoryUnitSampleIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.3
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
boxServicesStackTempSensorType OBJECT-TYPE
SYNTAX INTEGER {
fixed(1),
removable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of temperature sensor"
::= { boxServicesStackTempSensorsEntry 3 }boxsPwrUsageHistoryUnitSampleTime OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time at which the Sample was collected."
::= { boxsUnitPwrUsageHistoryEntry 3}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
The type of temperature sensor
Dell MIB copies (LibreNMS/Observium Community)
Description 2
Time at which the Sample was collected.
Dell MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: boxServicesStackTempSensorType
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"boxServicesStackTempSensorType",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"fixed",
"(",
"1",
")",
",",
"removable",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The type of temperature sensor\"",
"::=",
"{",
"boxServicesStackTempSensorsEntry",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"fixed",
1
],
[
"removable",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The type of temperature sensor"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Dell support.
Module: OLD-DNOS-BOXSERVICES-PRIVATE-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32'], 'RFC1213-MIB': ['DisplayString'], 'BROADCOM-REF-MIB': ['fastPath']}Status in source: current.
Names: boxsPwrUsageHistoryUnitSampleTime
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"boxsPwrUsageHistoryUnitSampleTime",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"(",
"SIZE",
"(",
"1",
".",
".",
"32",
")",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Time at which the Sample was collected.\"",
"::=",
"{",
"boxsUnitPwrUsageHistoryEntry",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"DisplayString",
[
"octetStringSubType",
[
[
1,
32
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Time at which the Sample was collected."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Dell support.
Module: DNOS-BOXSERVICES-PRIVATE-MIB
See published definition above
{'DNOS-TC': ['DeciInteger32', 'MilliInteger32', 'DBmHundreths'], 'HCNUM-TC': ['CounterBasedGauge64'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Gauge32'], 'RFC1213-MIB': ['DisplayString'], 'DELL-REF-MIB': ['dnOS']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.1 | boxsPwrUsageHistoryUnitIndex, boxServicesUnitIndex | 0 | 0 | |
| 1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.2 | boxsPwrUsageHistoryUnitSampleIndex, boxServicesStackTempSensorIndex | 0 | 0 | |
| 1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.4 | boxsPwrUsageHistoryUnitPowerConsumption, boxServicesStackTempSensorState | 0 | 0 | |
| 1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.5 | boxsPwrUsageHistoryStackPowerConsumption, boxServicesStackTempSensorTemperature | 0 | 0 |