The user-defined metered outlet ID string.
Sources for this description
Dell MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.674.10903.200.2.200.130.2.2.1.3
The user-defined metered outlet ID string.
Identification
{1 3 6 1 4 1 674 10903 200 2 200 130 2 2 1 3}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rPDUOutletMeteredStatusName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined metered outlet ID string."
::= { rPDUOutletMeteredStatusEntry 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The user-defined metered outlet ID string.
Dell MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: rPDUOutletMeteredStatusName
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rPDUOutletMeteredStatusName",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The user-defined metered outlet ID string.\"",
"::=",
"{",
"rPDUOutletMeteredStatusEntry",
"3",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The user-defined metered outlet ID string."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. Dell support.
Module: DellrPDU-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Same file in Observium Community.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.674.10903.200.2.200.130.2.2.1.1 | rPDUOutletMeteredStatusIndex | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.130.2.2.1.2 | rPDUOutletMeteredStatusNumber | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.130.2.2.1.4 | rPDUOutletMeteredStatusLayout | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.130.2.2.1.5 | rPDUOutMeteredStatPowerRating | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.130.2.2.1.6 | rPDUOutletMeteredStatusCurrent | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.130.2.2.1.7 | rPDUOutletMeteredStatusEnergy | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.130.2.2.1.8 | rPDUOutletMeteredStatusPower | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.130.2.2.1.9 | rPDUOutletMeteredStatPeakPower | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.130.2.2.1.10 | rPDUOutMeteredStatPeakPwrTime | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.130.2.2.1.11 | rPDUOutMeteredStatusLoadState | 0 | 0 |