The snapshot scheduler failed to delete snapshots in volume {{volumeName}}.
Sources for this description
Dell MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.674.11000.2000.200.20.7.2
The snapshot scheduler failed to delete snapshots in volume {{volumeName}}.
Identification
{1 3 6 1 4 1 674 11000 2000 200 20 7 2}
The displayed source records contain one distinct definition. Compare its source records.
fluidFSEventSnapshotFailedDeleteSnapshot NOTIFICATION-TYPE
OBJECTS { sysName, fluidFSEventsParamsSnapshotVolumeName }
STATUS current
DESCRIPTION
"The snapshot scheduler failed to delete snapshots in volume {{volumeName}}."
--#TYPE "Normal Event"
--#SUMMARY The snapshot scheduler failed to delete snapshots in volume %s.
--#ARGUMENTS {1}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE OK
::= { fluidFSEventsSnapshot 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The snapshot scheduler failed to delete snapshots in volume {{volumeName}}.
Dell MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: fluidFSEventSnapshotFailedDeleteSnapshot
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"fluidFSEventSnapshotFailedDeleteSnapshot",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"sysName",
",",
"fluidFSEventsParamsSnapshotVolumeName",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"The snapshot scheduler failed to delete snapshots in volume {{volumeName}}.\"",
"::=",
"{",
"fluidFSEventsSnapshot",
"2",
"}"
],
"syntax_tree": [
[
"Objects",
[
"sysName",
"fluidFSEventsParamsSnapshotVolumeName"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The snapshot scheduler failed to delete snapshots in volume {{volumeName}}."
],
null
]
}Vendor MIB copy from the Netdisco archive.
Module: FluidFS-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'NOTIFICATION-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'Counter64', 'enterprises'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType']}Related source files and packages:
Vendor MIB copy from the Observium Community archive. Dell support.
Module: FLUIDFS-CLUSTER-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'NOTIFICATION-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'Counter64', 'enterprises'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.674.11000.2000.200.20.7.1 | fluidFSEventSnapshotFailedCreateSnapshot | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.20.7.3 | fluidFSEventSnapshotScheduleDeleteSnapshotBySpace | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.20.7.8 | fluidFSEventSnapshotFailedToInitVMSnapshotsCreation | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.20.7.9 | fluidFSEventSnapshotFailedToPerformVMSnapshotsCreation | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.20.7.10 | fluidFSEventSnapshotFailedToPerformVMSnapshotsCleanup | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.20.7.11 | fluidFSEventSnapshotSnapshotIsNotVMConsistent | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.20.7.12 | fluidFSEventSnapshotSnapshotDeltaFailed | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.20.7.13 | fluidFSEventSnapshotSnapshotDeltaSucceded | 0 | 0 | |