Status in source: current.
Names: fluidFSEventHealthStoreAccessProblem
Technical details
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"fluidFSEventHealthStoreAccessProblem",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"sysName",
",",
"fluidFSEventsParamsHealthDomainId",
",",
"fluidFSEventsParamsHealthNodeId",
",",
"fluidFSEventsParamsHealthSetId",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"Lost communication to storage from NAS controller {{nodeId}}. Description: The system identified a communication problem between NAS controller {{nodeId}} and the storage controllers which may affect system performance. Action Items: The system constantly monitors the validity of communication between NAS controllers and Storage controller. This event is issued once the system identifies a communication issue. If the system was recently deployed or any of its components were recently moved, verify that all connections and configurations are according to the recommendations. If the system was functioning optimally for a while and this is a new event it is most likely due to a physical problem (like a bad/loose cable) or a change in network configuration which affects the components communication. Verify that all the network cables are correctly connected to the relevant NAS controller. Verify that all the iSCSI switches are up and running. If any change was introduced to the environment (new physical switch, new switch configuration), try to revert this change in order to understand the cause of the problem. Verify that the iSCSI switch is configured according to the recommendation. If the problem is persistent after verifying all the above, it is recommended to power cycle the problematic NAS controller using the UI. Internal Information: Domain {{domainId}} setId {{setId}}\"",
"::=",
"{",
"fluidFSEventsHealth",
"24",
"}"
],
"syntax_tree": [
[
"Objects",
[
"sysName",
"fluidFSEventsParamsHealthDomainId",
"fluidFSEventsParamsHealthNodeId",
"fluidFSEventsParamsHealthSetId"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Lost communication to storage from NAS controller {{nodeId}}. Description: The system identified a communication problem between NAS controller {{nodeId}} and the storage controllers which may affect system performance. Action Items: The system constantly monitors the validity of communication between NAS controllers and Storage controller. This event is issued once the system identifies a communication issue. If the system was recently deployed or any of its components were recently moved, verify that all connections and configurations are according to the recommendations. If the system was functioning optimally for a while and this is a new event it is most likely due to a physical problem (like a bad/loose cable) or a change in network configuration which affects the components communication. Verify that all the network cables are correctly connected to the relevant NAS controller. Verify that all the iSCSI switches are up and running. If any change was introduced to the environment (new physical switch, new switch configuration), try to revert this change in order to understand the cause of the problem. Verify that the iSCSI switch is configured according to the recommendation. If the problem is persistent after verifying all the above, it is recommended to power cycle the problematic NAS controller using the UI. Internal Information: Domain {{domainId}} setId {{setId}}"
],
null
]
}
- Netdisco MIB archive copies
· Publisher's source file: FluidFS-Traps-MIB.txt
Vendor MIB copy from the Netdisco archive.
Module: FluidFS-MIB
See published definition above
Module imports
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'NOTIFICATION-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'Counter64', 'enterprises'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType']}
· Download FluidFS-Traps-MIB.txt
Related source files and packages:
- Dell MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Dell support.
Module: FLUIDFS-CLUSTER-MIB
Same published definition
Module imports
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'NOTIFICATION-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'Counter64', 'enterprises'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType']}
· Download FLUIDFS-CLUSTER-MIB