LUN SCSI ID
Sources for this description
Dell MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.674.11000.2000.200.21.2.14
LUN SCSI ID
Identification
{1 3 6 1 4 1 674 11000 2000 200 21 2 14}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
fluidFSEventsParamsHardwareLunId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LUN SCSI ID"
::= { fluidFSEventsParamsHardware 14 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
LUN SCSI ID
Dell MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: fluidFSEventsParamsHardwareLunId
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fluidFSEventsParamsHardwareLunId",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"LUN SCSI ID\"",
"::=",
"{",
"fluidFSEventsParamsHardware",
"14",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"LUN SCSI ID"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Netdisco archive.
Module: FluidFS-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'NOTIFICATION-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'Counter64', 'enterprises'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType']}Related source files and packages:
Vendor MIB copy from the Observium Community archive. Dell support.
Module: FLUIDFS-CLUSTER-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'NOTIFICATION-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'Counter64', 'enterprises'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.674.11000.2000.200.21.2.1 | fluidFSEventsParamsHardwareNodeName | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.2 | fluidFSEventsParamsHardwareNetworkId | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.3 | fluidFSEventsParamsHardwarePrefix | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.4 | fluidFSEventsParamsHardwareCpuName | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.5 | fluidFSEventsParamsHardwareCpuTemperature | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.6 | fluidFSEventsParamsHardwareVlanTag | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.7 | fluidFSEventsParamsHardwareDestinationNetwork | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.8 | fluidFSEventsParamsHardwareCpuSpeed | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.9 | fluidFSEventsParamsHardwareAverageSpeed | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.10 | fluidFSEventsParamsHardwareNodeId | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.11 | fluidFSEventsParamsHardwareNetworkName | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.12 | fluidFSEventsParamsHardwarePacketLoss | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.13 | fluidFSEventsParamsHardwareEthName | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.15 | fluidFSEventsParamsHardwareFromNode | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.16 | fluidFSEventsParamsHardwareToNode | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.17 | fluidFSEventsParamsHardwareFromEth | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.18 | fluidFSEventsParamsHardwareToEth | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.19 | fluidFSEventsParamsHardwareTapeName | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.20 | fluidFSEventsParamsHardwareBatteryPercentage | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.21 | fluidFSEventsParamsHardwareBatteryRemainTime | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.22 | fluidFSEventsParamsHardwareSubnetName | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.23 | fluidFSEventsParamsHardwareHostName | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.24 | fluidFSEventsParamsHardwareBatteryLastReplace | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.25 | fluidFSEventsParamsHardwareDeviceTypeName | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.26 | fluidFSEventsParamsHardwareDeviceName | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.27 | fluidFSEventsParamsHardwareTemperature | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.28 | fluidFSEventsParamsHardwareMeltingDistance | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.29 | fluidFSEventsParamsHardwareDeviceState | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.30 | fluidFSEventsParamsHardwareFirstNodeId | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.31 | fluidFSEventsParamsHardwareSecondNodeId | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.32 | fluidFSEventsParamsHardwareBondName | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.33 | fluidFSEventsParamsHardwareBandwidth | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.34 | fluidFSEventsParamsHardwareDiskName | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.35 | fluidFSEventsParamsHardwareMemoryFirstNode | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.36 | fluidFSEventsParamsHardwareMemorySecondNode | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.37 | fluidFSEventsParamsHardwareActualMtu | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.38 | fluidFSEventsParamsHardwareOptimalMtu | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.39 | fluidFSEventsParamsHardwareBpsLogInfo | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.40 | fluidFSEventsParamsHardwareBpsAlarm | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.41 | fluidFSEventsParamsHardwarePowerSuppliesRedundancyStatus | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.42 | fluidFSEventsParamsHardwarePowerSuppliesElementStatus | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.43 | fluidFSEventsParamsHardwarePowerSuppliesElementLocation | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.44 | fluidFSEventsParamsHardwarePowerSuppliesElementsCount | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.45 | fluidFSEventsParamsHardwareChassisID | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.46 | fluidFSEventsParamsHardwareTemperatureSensorName | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.47 | fluidFSEventsParamsHardwareTemperatureSensorStatus | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.48 | fluidFSEventsParamsHardwareTemperatureSensorValue | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.49 | fluidFSEventsParamsHardwareTemperatureSensorErrorThreshold | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.50 | fluidFSEventsParamsHardwareTemperatureSensorWarningThreshold | 0 | 0 | |
| 1.3.6.1.4.1.674.11000.2000.200.21.2.51 | fluidFSEventsParamsHardwarePowerSupplyName | 0 | 0 |