| 1.3.6.1.4.1.683.6.2.3.2.1.1 |
outputIndex | 0 | 0 |
A unique value for each physical output port. Its value ranges between 1 and the value of outputNumPorts. The value for each pro… |
| 1.3.6.1.4.1.683.6.2.3.2.1.2 |
outputName | 0 | 0 |
A textual description of the output port. |
| 1.3.6.1.4.1.683.6.2.3.2.1.3 |
outputStatusString | 0 | 0 |
A string indicating the status of the physical output port. |
| 1.3.6.1.4.1.683.6.2.3.2.1.4 |
outputStatus | 0 | 0 |
Indicates status of the printer. Get outputExtendedStatus for further information. |
| 1.3.6.1.4.1.683.6.2.3.2.1.5 |
outputExtendedStatus | 0 | 0 |
Indicates printer status to be used in conjunction with outputStatus. |
| 1.3.6.1.4.1.683.6.2.3.2.1.6 |
outputPrinter | 0 | 0 |
The type of printer the output port is attached to.
Even if the group is supported, this variable may not be supported. |
| 1.3.6.1.4.1.683.6.2.3.2.1.7 |
outputLanguageSwitching | 0 | 0 |
Indicates the language switching option for the physical port.
Even if the group is supported, this variable may not be supported. |
| 1.3.6.1.4.1.683.6.2.3.2.1.8 |
outputConfigLanguage | 0 | 0 |
Indicates the language that configuration pages will be printed in.
If set to off, a config sheet will not be printed on this port. |
| 1.3.6.1.4.1.683.6.2.3.2.1.9 |
outputPCLString | 0 | 0 |
This string will be sent out the physical port if (1) outputLanguageSwitching is set to PCL or outputLanguageSwitching is set to … |
| 1.3.6.1.4.1.683.6.2.3.2.1.10 |
outputPSString | 0 | 0 |
This string will be sent out the physical port if (1) outputLanguageSwitching is set to PostScript or outputLanguageSwitching is … |
| 1.3.6.1.4.1.683.6.2.3.2.1.11 |
outputCascaded | 0 | 0 |
A value of 2 indicates that the physical output port is connected to an Extended System's printer sharing device.
Even if the gro… |
| 1.3.6.1.4.1.683.6.2.3.2.1.13 |
outputOwner | 0 | 0 |
Indicates which protocol or task currently is printing on the port. |
| 1.3.6.1.4.1.683.6.2.3.2.1.14 |
outputBIDIStatusEnabled | 0 | 0 |
A value of 2 indicates that the BIDI status system is enabled. |
| 1.3.6.1.4.1.683.6.2.3.2.1.15 |
outputPrinterModel | 0 | 0 |
A string indicating the printer model attached to the output port. |
| 1.3.6.1.4.1.683.6.2.3.2.1.16 |
outputPrinterDisplay | 0 | 0 |
A string indicating the message on the attached printer front panel. |
| 1.3.6.1.4.1.683.6.2.3.2.1.17 |
outputCapabilities | 0 | 0 |
This field is implemented as a BIT mask. If the bit is set then the port is capable of functioning in this mode.
Bit Property 0… |
| 1.3.6.1.4.1.683.6.2.3.2.1.18 |
outputHandshake | 0 | 0 |
If the port in serial mode operation this indicates the handshaking method being used. Setting this value to 'not- supported' wi… |
| 1.3.6.1.4.1.683.6.2.3.2.1.19 |
outputDataBits | 0 | 0 |
If the port in serial mode operation this indicates the number of data bits being used. Setting this value to 'not- supported' w… |
| 1.3.6.1.4.1.683.6.2.3.2.1.20 |
outputStopBits | 0 | 0 |
If the port in serial mode operation this indicates the number of stop bits being used. Setting this value to 'not- supported' w… |
| 1.3.6.1.4.1.683.6.2.3.2.1.21 |
outputParity | 0 | 0 |
If the port in serial mode operation this indicates the parity checking method being used. Setting this value to 'not- supported… |
| 1.3.6.1.4.1.683.6.2.3.2.1.22 |
outputBaudRate | 0 | 0 |
If the port in serial mode operation this indicates the baud rate being used. Setting this value on non serial capable ports will… |
| 1.3.6.1.4.1.683.6.2.3.2.1.23 |
outputProtocolManager | 0 | 0 |
Indicates the type of output protocol manager being used on the port. Protocol-none means either there is no printer attached o… |