Status of MDU power inlets
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.6853.3.5
Status of MDU power inlets
Identification
{1 3 6 1 4 1 6853 3 5}
Notes below names come from selected MIB definitions.
| Value | Name and source notes |
|---|---|
| 1 | totalLoss |
| 2 | input1OK |
| 3 | input2OK |
| 4 | allOk note: a single input MDU would report allOk if power is present |
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.6853.3.5.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
mduPowerStatus OBJECT-TYPE
SYNTAX INTEGER
{
totalLoss(1),
input1OK(2),
input2OK(3),
allOk(4) -- note: a single input MDU would report allOk if power is present
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status of MDU power inlets"
::= { mdu12 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Status of MDU power inlets
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: mduPowerStatus
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mduPowerStatus",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"totalLoss",
"(",
"1",
")",
",",
"input1OK",
"(",
"2",
")",
",",
"input2OK",
"(",
"3",
")",
",",
"allOk",
"(",
"4",
")",
"}",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Status of MDU power inlets\"",
"::=",
"{",
"mdu12",
"5",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"totalLoss",
1
],
[
"input1OK",
2
],
[
"input2OK",
3
],
[
"allOk",
4
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Status of MDU power inlets"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: TSL-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'Opaque']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6853.3.1 | mdu12Ident | 0 | 0 | |
| 1.3.6.1.4.1.6853.3.2 | mduPowerOn | 0 | 0 | |
| 1.3.6.1.4.1.6853.3.3 | mduSeqDelay | 0 | 0 | |
| 1.3.6.1.4.1.6853.3.4 | mduOutputTable | 1 | 11 | |
| 1.3.6.1.4.1.6853.3.6 | mduVoltageCal | 0 | 0 | |
| 1.3.6.1.4.1.6853.3.7 | mduVoltage | 0 | 0 | |
| 1.3.6.1.4.1.6853.3.8 | mduVoltageFloor | 0 | 0 | |
| 1.3.6.1.4.1.6853.3.9 | mduVoltageLimit | 0 | 0 | |
| 1.3.6.1.4.1.6853.3.10 | mduTotalCurrent | 0 | 0 | |
| 1.3.6.1.4.1.6853.3.11 | mduCurrentLimit | 0 | 0 | |
| 1.3.6.1.4.1.6853.3.12 | mduAuxRly1 | 0 | 0 | |
| 1.3.6.1.4.1.6853.3.13 | mduAuxRly2 | 0 | 0 |