OID reference

cmgHardwareFaultMask

1.3.6.1.4.1.6889.2.9.1.1.10.12

Description

Each bit of this value set to '1' indicates a specific fault in the module. Octets are numbered in the order in which they appear in the PDU. Bits are numbered from the most-significant leftmost bit in the octet (bit 0) to the least-significant rightmost bit (bit 7). Cajun numbering continues across octets, so that oc…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.6889.2.9.1.1.10 (cmgHardware)
Node code
12
Node name
cmgHardwareFaultMask
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.6889.2.9.1.1.10.12
URN notation
urn:oid:1.3.6.1.4.1.6889.2.9.1.1.10.12
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 6889 2 9 1 1 10 12}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) avaya(6889) mibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) avaya(6889) avayaMibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) avaya(6889) mibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) avaya(6889) avayaMibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) avaya(6889) mibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) avaya(6889) avayaMibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) avaya(6889) mibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) avaya(6889) avayaMibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) avaya(6889) mibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) avaya(6889) avayaMibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) avaya(6889) mibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) avaya(6889) avayaMibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) avaya(6889) mibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) avaya(6889) avayaMibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) avaya(6889) mibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) avaya(6889) avayaMibs(2) g700MediaGatewayMIB(9) cmgmib(1) cmgChassis(1) cmgHardware(10) cmgHardwareFaultMask(12)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/6889/2/9/1/1/10/12
  • /ISO/Identified-Organization/6/1/4/1/6889/2/9/1/1/10/12
  • /ISO/3/6/1/4/1/6889/2/9/1/1/10/12
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/avaya/mibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/identified-organization/dod/internet/private/enterprise/avaya/avayaMibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/identified-organization/dod/internet/private/enterprises/avaya/mibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/identified-organization/dod/internet/private/enterprises/avaya/avayaMibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/avaya/mibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/avaya/avayaMibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/identified-organization/dod/internet/private/vendor-objects/avaya/mibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/identified-organization/dod/internet/private/vendor-objects/avaya/avayaMibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/org/dod/internet/private/enterprise/avaya/mibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/org/dod/internet/private/enterprise/avaya/avayaMibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/org/dod/internet/private/enterprises/avaya/mibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/org/dod/internet/private/enterprises/avaya/avayaMibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/org/dod/internet/private/ldap-enterprise/avaya/mibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/org/dod/internet/private/ldap-enterprise/avaya/avayaMibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/org/dod/internet/private/vendor-objects/avaya/mibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • /iso/org/dod/internet/private/vendor-objects/avaya/avayaMibs/g700MediaGatewayMIB/cmgmib/cmgChassis/cmgHardware/cmgHardwareFaultMask
  • Additional combinations skipped.

SNMP properties

Value type
OCTET STRING
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed size (octets)
0–3

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.6889.2.9.1.1.10.12.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

cmgHardwareFaultMask OBJECT-TYPE
	SYNTAX      OCTET STRING (SIZE (0..3))
	MAX-ACCESS  read-only
	STATUS      current
	DESCRIPTION
	"Each bit of this value set to '1' indicates a specific fault
	in the module.

	Octets are numbered in the order in which they appear in the PDU.
	Bits are numbered from the most-significant leftmost bit in the
	octet (bit 0) to the least-significant rightmost bit (bit 7).

	Cajun numbering continues across octets, so that octet 1 bit 0 is
	called bit 8 in the Cajun scheme.  That number is also shown below,
	with the octet value for each single bit set.

	Octet 0 high-order 4 bits show fan status.
	Octet 0 low-order 4 bits show temperature status.
	Octet 1 shows power supply status.
	Octet 2 shows other alarms.

    Cajun  Octet Octet
    bit#   /bit# value	Meaning
    -----  ----- -----	-------
    0      0/0   0x80	Multiple fan warning: at least two fans have been operating
			at less than 90% of their nominal speed for 5 minutes or
			more.  This may be an early warning of overheating.

    1      0/1   0x40	PSU fan brief failure warning: the power supply fan has been
			operating at less than 90% of its nominal speed for 10 minutes
			or more, but less than 15 minutes.  This may be an early
			warning of overheating.

    2      0/2   0x20	PSU fan prolonged failure warning: the power supply fan has
			been operating at less than 90% of its nominal speed for 15
			minutes or more.  This may be an early warning of overheating.

    3      0/3       	Unused.

    4      0/4   0x08	Temperature warning: cmgCpuTemp has exceeded its warning
			threshold.

    5      0/5   0x04	Temperature warning: cmgDspTemp has exceeded its warning
			threshold.

    6     0/6	Unused.
    
    7     0/7   Power On Status Test failure -NCE, QUICC test failures on power up

    8      1/0   0x80	The +5.1 v power supply to the MG processor is out of range.
    9      1/1   0x40	The -48 v power supply to the media modules is out of range.
   10      1/2   0x20	The +3.3 v power supply to the VoIP complexes is out of range.
   11      1/3   0x10	The +1.58 v power supply to the DSP units is out of range.
   12      1/4   0x08	The +2.5 v power supply to the 8260 processor is out of range.
   13      1/5   0x04	The -48 v auxiliary power supply to the endpoints is out of
			range.
   14      1/6   0x02	The +12 v power supply to the fans is out of range.
   15      1/7		Unused.

   16      2/0   0x80	Clock synchronization signal is lost.
   17      2/1   0x40	Clock synchronization signal warning. Only one clock
                        syncronization signal source remains.
   18      2/2   0x20   Clock synchronization signal excessive switching.
   19      2/3   0x10   TDM Test Expansion Box 1 Failure
   20      2/4   0x08   TDM Test Expansion Box 2 Failure
   21      2/5   0x04   PoE Power Supply Base Box Failure
   22      2/6   0x02   PoE Power Supply Expansion Box 1 Failure
   23      2/7   0x01   PoE Power Supply Expansion Box 2 Failure
	"
	::= { cmgHardware 12 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Each bit of this value set to '1' indicates a specific fault in the module. Octets are numbered in the order in which they appear in the PDU. Bits are numbered from the most-significant leftmost bit in the octet (bit 0) to the least-significant rightmost bit (bit 7). Cajun numbering continues across octets, so that octet 1 bit 0 is called bit 8 in the Cajun scheme. That number is also shown below, with the octet value for each single bit set. Octet 0 high-order 4 bits show fan status. Octet 0 low-order 4 bits show temperature status. Octet 1 shows power supply status. Octet 2 shows other alarms. Cajun Octet Octet bit# /bit# value Meaning ----- ----- ----- ------- 0 0/0 0x80 Multiple fan warning: at least two fans have been operating at less than 90% of their nominal speed for 5 minutes or more. This may be an early warning of overheating. 1 0/1 0x40 PSU fan brief failure warning: the power supply fan has been operating at less than 90% of its nominal speed for 10 minutes or more, but less than 15 minutes. This may be an early warning of overheating. 2 0/2 0x20 PSU fan prolonged failure warning: the power supply fan has been operating at less than 90% of its nominal speed for 15 minutes or more. This may be an early warning of overheating. 3 0/3 Unused. 4 0/4 0x08 Temperature warning: cmgCpuTemp has exceeded its warning threshold. 5 0/5 0x04 Temperature warning: cmgDspTemp has exceeded its warning threshold. 6 0/6 Unused. 7 0/7 Power On Status Test failure -NCE, QUICC test failures on power up 8 1/0 0x80 The +5.1 v power supply to the MG processor is out of range. 9 1/1 0x40 The -48 v power supply to the media modules is out of range. 10 1/2 0x20 The +3.3 v power supply to the VoIP complexes is out of range. 11 1/3 0x10 The +1.58 v power supply to the DSP units is out of range. 12 1/4 0x08 The +2.5 v power supply to the 8260 processor is out of range. 13 1/5 0x04 The -48 v auxiliary power supply to the endpoints is out of range. 14 1/6 0x02 The +12 v power supply to the fans is out of range. 15 1/7 Unused. 16 2/0 0x80 Clock synchronization signal is lost. 17 2/1 0x40 Clock synchronization signal warning. Only one clock syncronization signal source remains. 18 2/2 0x20 Clock synchronization signal excessive switching. 19 2/3 0x10 TDM Test Expansion Box 1 Failure 20 2/4 0x08 TDM Test Expansion Box 2 Failure 21 2/5 0x04 PoE Power Supply Base Box Failure 22 2/6 0x02 PoE Power Supply Expansion Box 1 Failure 23 2/7 0x01 PoE Power Supply Expansion Box 2 Failure

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Avaya MIB copies (MibBrowser.online)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Avaya MIB copies (MibBrowser.online)1 record · 2 sources

Description 1

cmgHardwareFaultMask · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Avaya MIB copies (MibBrowser.online)2 sources

Status in source: current.

Names: cmgHardwareFaultMask

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "cmgHardwareFaultMask",
    "OBJECT-TYPE",
    "SYNTAX",
    "OCTET",
    "STRING",
    "(",
    "SIZE",
    "(",
    "0",
    ".",
    ".",
    "3",
    ")",
    ")",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Each bit of this value set to '1' indicates a specific fault in the module. Octets are numbered in the order in which they appear in the PDU. Bits are numbered from the most-significant leftmost bit in the octet (bit 0) to the least-significant rightmost bit (bit 7). Cajun numbering continues across octets, so that octet 1 bit 0 is called bit 8 in the Cajun scheme. That number is also shown below, with the octet value for each single bit set. Octet 0 high-order 4 bits show fan status. Octet 0 low-order 4 bits show temperature status. Octet 1 shows power supply status. Octet 2 shows other alarms. Cajun Octet Octet bit# /bit# value Meaning ----- ----- ----- ------- 0 0/0 0x80 Multiple fan warning: at least two fans have been operating at less than 90% of their nominal speed for 5 minutes or more. This may be an early warning of overheating. 1 0/1 0x40 PSU fan brief failure warning: the power supply fan has been operating at less than 90% of its nominal speed for 10 minutes or more, but less than 15 minutes. This may be an early warning of overheating. 2 0/2 0x20 PSU fan prolonged failure warning: the power supply fan has been operating at less than 90% of its nominal speed for 15 minutes or more. This may be an early warning of overheating. 3 0/3 Unused. 4 0/4 0x08 Temperature warning: cmgCpuTemp has exceeded its warning threshold. 5 0/5 0x04 Temperature warning: cmgDspTemp has exceeded its warning threshold. 6 0/6 Unused. 7 0/7 Power On Status Test failure -NCE, QUICC test failures on power up 8 1/0 0x80 The +5.1 v power supply to the MG processor is out of range. 9 1/1 0x40 The -48 v power supply to the media modules is out of range. 10 1/2 0x20 The +3.3 v power supply to the VoIP complexes is out of range. 11 1/3 0x10 The +1.58 v power supply to the DSP units is out of range. 12 1/4 0x08 The +2.5 v power supply to the 8260 processor is out of range. 13 1/5 0x04 The -48 v auxiliary power supply to the endpoints is out of range. 14 1/6 0x02 The +12 v power supply to the fans is out of range. 15 1/7 Unused. 16 2/0 0x80 Clock synchronization signal is lost. 17 2/1 0x40 Clock synchronization signal warning. Only one clock syncronization signal source remains. 18 2/2 0x20 Clock synchronization signal excessive switching. 19 2/3 0x10 TDM Test Expansion Box 1 Failure 20 2/4 0x08 TDM Test Expansion Box 2 Failure 21 2/5 0x04 PoE Power Supply Base Box Failure 22 2/6 0x02 PoE Power Supply Expansion Box 1 Failure 23 2/7 0x01 PoE Power Supply Expansion Box 2 Failure \"",
    "::=",
    "{",
    "cmgHardware",
    "12",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "OCTET STRING",
      [
        "octetStringSubType",
        [
          [
            0,
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Each bit of this value set to '1' indicates a specific fault in the module. Octets are numbered in the order in which they appear in the PDU. Bits are numbered from the most-significant leftmost bit in the octet (bit 0) to the least-significant rightmost bit (bit 7). Cajun numbering continues across octets, so that octet 1 bit 0 is called bit 8 in the Cajun scheme. That number is also shown below, with the octet value for each single bit set. Octet 0 high-order 4 bits show fan status. Octet 0 low-order 4 bits show temperature status. Octet 1 shows power supply status. Octet 2 shows other alarms. Cajun Octet Octet bit# /bit# value Meaning ----- ----- ----- ------- 0 0/0 0x80 Multiple fan warning: at least two fans have been operating at less than 90% of their nominal speed for 5 minutes or more. This may be an early warning of overheating. 1 0/1 0x40 PSU fan brief failure warning: the power supply fan has been operating at less than 90% of its nominal speed for 10 minutes or more, but less than 15 minutes. This may be an early warning of overheating. 2 0/2 0x20 PSU fan prolonged failure warning: the power supply fan has been operating at less than 90% of its nominal speed for 15 minutes or more. This may be an early warning of overheating. 3 0/3 Unused. 4 0/4 0x08 Temperature warning: cmgCpuTemp has exceeded its warning threshold. 5 0/5 0x04 Temperature warning: cmgDspTemp has exceeded its warning threshold. 6 0/6 Unused. 7 0/7 Power On Status Test failure -NCE, QUICC test failures on power up 8 1/0 0x80 The +5.1 v power supply to the MG processor is out of range. 9 1/1 0x40 The -48 v power supply to the media modules is out of range. 10 1/2 0x20 The +3.3 v power supply to the VoIP complexes is out of range. 11 1/3 0x10 The +1.58 v power supply to the DSP units is out of range. 12 1/4 0x08 The +2.5 v power supply to the 8260 processor is out of range. 13 1/5 0x04 The -48 v auxiliary power supply to the endpoints is out of range. 14 1/6 0x02 The +12 v power supply to the fans is out of range. 15 1/7 Unused. 16 2/0 0x80 Clock synchronization signal is lost. 17 2/1 0x40 Clock synchronization signal warning. Only one clock syncronization signal source remains. 18 2/2 0x20 Clock synchronization signal excessive switching. 19 2/3 0x10 TDM Test Expansion Box 1 Failure 20 2/4 0x08 TDM Test Expansion Box 2 Failure 21 2/5 0x04 PoE Power Supply Base Box Failure 22 2/6 0x02 PoE Power Supply Expansion Box 1 Failure 23 2/7 0x01 PoE Power Supply Expansion Box 2 Failure"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.6889)

Dan Romascanu

Siblings (13)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.6889.2.9.1.1.10.1 cmgCpuTemp00
1.3.6.1.4.1.6889.2.9.1.1.10.2 cmgCpuTempWarningThresh00
1.3.6.1.4.1.6889.2.9.1.1.10.3 cmgCpuTempShutdownThresh00
1.3.6.1.4.1.6889.2.9.1.1.10.4 cmgDspTemp00
1.3.6.1.4.1.6889.2.9.1.1.10.5 cmgDspTempWarningThresh00
1.3.6.1.4.1.6889.2.9.1.1.10.6 cmgDspTempShutdownThresh00
1.3.6.1.4.1.6889.2.9.1.1.10.7 cmgPowerMgProcessor00
1.3.6.1.4.1.6889.2.9.1.1.10.8 cmgPowerMediaModules00
1.3.6.1.4.1.6889.2.9.1.1.10.9 cmgPowerVoipComplex00
1.3.6.1.4.1.6889.2.9.1.1.10.10 cmgPowerDsp00
1.3.6.1.4.1.6889.2.9.1.1.10.11 cmgPower826000
1.3.6.1.4.1.6889.2.9.1.1.10.13 cmgHardwareStatusMask00
1.3.6.1.4.1.6889.2.9.1.1.10.14 cmgHardwareFanLowSpeedLevel00