Status in source: current.
Names: cmgHardwareFaultMask
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cmgHardwareFaultMask",
"OBJECT-TYPE",
"SYNTAX",
"OCTET",
"STRING",
"(",
"SIZE",
"(",
"0",
".",
".",
"3",
")",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Each bit of this value set to '1' indicates a specific fault in the module. Octets are numbered in the order in which they appear in the PDU. Bits are numbered from the most-significant leftmost bit in the octet (bit 0) to the least-significant rightmost bit (bit 7). Cajun numbering continues across octets, so that octet 1 bit 0 is called bit 8 in the Cajun scheme. That number is also shown below, with the octet value for each single bit set. Octet 0 high-order 4 bits show fan status. Octet 0 low-order 4 bits show temperature status. Octet 1 shows power supply status. Octet 2 shows other alarms. Cajun Octet Octet bit# /bit# value Meaning ----- ----- ----- ------- 0 0/0 0x80 Multiple fan warning: at least two fans have been operating at less than 90% of their nominal speed for 5 minutes or more. This may be an early warning of overheating. 1 0/1 0x40 PSU fan brief failure warning: the power supply fan has been operating at less than 90% of its nominal speed for 10 minutes or more, but less than 15 minutes. This may be an early warning of overheating. 2 0/2 0x20 PSU fan prolonged failure warning: the power supply fan has been operating at less than 90% of its nominal speed for 15 minutes or more. This may be an early warning of overheating. 3 0/3 Unused. 4 0/4 0x08 Temperature warning: cmgCpuTemp has exceeded its warning threshold. 5 0/5 0x04 Temperature warning: cmgDspTemp has exceeded its warning threshold. 6 0/6 Unused. 7 0/7 Power On Status Test failure -NCE, QUICC test failures on power up 8 1/0 0x80 The +5.1 v power supply to the MG processor is out of range. 9 1/1 0x40 The -48 v power supply to the media modules is out of range. 10 1/2 0x20 The +3.3 v power supply to the VoIP complexes is out of range. 11 1/3 0x10 The +1.58 v power supply to the DSP units is out of range. 12 1/4 0x08 The +2.5 v power supply to the 8260 processor is out of range. 13 1/5 0x04 The -48 v auxiliary power supply to the endpoints is out of range. 14 1/6 0x02 The +12 v power supply to the fans is out of range. 15 1/7 Unused. 16 2/0 0x80 Clock synchronization signal is lost. 17 2/1 0x40 Clock synchronization signal warning. Only one clock syncronization signal source remains. 18 2/2 0x20 Clock synchronization signal excessive switching. 19 2/3 0x10 TDM Test Expansion Box 1 Failure 20 2/4 0x08 TDM Test Expansion Box 2 Failure 21 2/5 0x04 PoE Power Supply Base Box Failure 22 2/6 0x02 PoE Power Supply Expansion Box 1 Failure 23 2/7 0x01 PoE Power Supply Expansion Box 2 Failure \"",
"::=",
"{",
"cmgHardware",
"12",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"OCTET STRING",
[
"octetStringSubType",
[
[
0,
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Each bit of this value set to '1' indicates a specific fault in the module. Octets are numbered in the order in which they appear in the PDU. Bits are numbered from the most-significant leftmost bit in the octet (bit 0) to the least-significant rightmost bit (bit 7). Cajun numbering continues across octets, so that octet 1 bit 0 is called bit 8 in the Cajun scheme. That number is also shown below, with the octet value for each single bit set. Octet 0 high-order 4 bits show fan status. Octet 0 low-order 4 bits show temperature status. Octet 1 shows power supply status. Octet 2 shows other alarms. Cajun Octet Octet bit# /bit# value Meaning ----- ----- ----- ------- 0 0/0 0x80 Multiple fan warning: at least two fans have been operating at less than 90% of their nominal speed for 5 minutes or more. This may be an early warning of overheating. 1 0/1 0x40 PSU fan brief failure warning: the power supply fan has been operating at less than 90% of its nominal speed for 10 minutes or more, but less than 15 minutes. This may be an early warning of overheating. 2 0/2 0x20 PSU fan prolonged failure warning: the power supply fan has been operating at less than 90% of its nominal speed for 15 minutes or more. This may be an early warning of overheating. 3 0/3 Unused. 4 0/4 0x08 Temperature warning: cmgCpuTemp has exceeded its warning threshold. 5 0/5 0x04 Temperature warning: cmgDspTemp has exceeded its warning threshold. 6 0/6 Unused. 7 0/7 Power On Status Test failure -NCE, QUICC test failures on power up 8 1/0 0x80 The +5.1 v power supply to the MG processor is out of range. 9 1/1 0x40 The -48 v power supply to the media modules is out of range. 10 1/2 0x20 The +3.3 v power supply to the VoIP complexes is out of range. 11 1/3 0x10 The +1.58 v power supply to the DSP units is out of range. 12 1/4 0x08 The +2.5 v power supply to the 8260 processor is out of range. 13 1/5 0x04 The -48 v auxiliary power supply to the endpoints is out of range. 14 1/6 0x02 The +12 v power supply to the fans is out of range. 15 1/7 Unused. 16 2/0 0x80 Clock synchronization signal is lost. 17 2/1 0x40 Clock synchronization signal warning. Only one clock syncronization signal source remains. 18 2/2 0x20 Clock synchronization signal excessive switching. 19 2/3 0x10 TDM Test Expansion Box 1 Failure 20 2/4 0x08 TDM Test Expansion Box 2 Failure 21 2/5 0x04 PoE Power Supply Base Box Failure 22 2/6 0x02 PoE Power Supply Expansion Box 1 Failure 23 2/7 0x01 PoE Power Supply Expansion Box 2 Failure"
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: G700-MG-MIB
See published definition above
Module imports
{'LOAD-MIB': ['genAppFileId', 'genAppFileName', 'genAppFileVersionNumber', 'genOpLastFailureIndex', 'genOpLastWarningDisplay'], 'SNMPv2-TC': ['RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'IpAddress', 'Integer32', 'enterprises'], 'RFC1155-SMI': ['TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType']}
· Download G700-MG-MIB
- Avaya MIB copies (MibBrowser.online)
· Publisher's source file: G700-MG-MIB — archive MIB indexed for Avaya
Vendor MIB copy from the MibBrowser.online archive.
Avaya support.
Module: G700-MG-MIB
Same published definition
Module imports
{'LOAD-MIB': ['genAppFileId', 'genAppFileName', 'genAppFileVersionNumber', 'genOpLastFailureIndex', 'genOpLastWarningDisplay'], 'SNMPv2-TC': ['RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'IpAddress', 'Integer32', 'enterprises'], 'RFC1155-SMI': ['TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType']}
· Download G700-MG-MIB — archive MIB indexed for Avaya
Related source files and packages:
More related source documents