Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cmgMgpFaultMask",
"OBJECT-TYPE",
"SYNTAX",
"OCTET",
"STRING",
"(",
"SIZE",
"(",
"0",
".",
".",
"3",
")",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Each bit of this value set to '1' indicates a specific fault in the Media Gateway processor. Octets are numbered in the order in which they appear in the PDU. Bits are numbered from the most-significant leftmost bit in the octet (bit 0) to the least-significant rightmost bit (bit 7). Cajun numbering continues across octets, so that octet 1 bit 0 is called bit 8 in the Cajun scheme. That number is also shown below, with the octet value for each single bit set. Cajun Octet Octet bit# bit# value Meaning ----- ----- ----- ------- 0 0/0 0x80 Memory failure. 1 0/1 0x40 DHCP request failure. 2 0/2 0x20 Firmware download failure. 3 0/3 0x10 Software watchdog alert - MG processes restarting. 4 0/4 0x08 Internal Communications Controller expected but not present. 5 0/5 0x04 Internal Communications Controller automatic reset. 6 0/6 0x02 Media Gateway busy-out. 7 0/7 0x01 Configuration upload failure. 8 1/0 0x80 Primary controller not found. 9 1/1 0x40 No controller found. 10 1/2 0x20 Registration failure. 11 1/3 0x10 H.248 control link down. 12-13 1/4-5 Unused. 14 1/6 0x02 Maintenance test failure. 15 1/7 0x01 Maintenance test failure over threshold. 16 2/0 0x80 Configuration download failure. 17-23 2/0-7 Unused. \"",
"::=",
"{",
"cmgProcessorConfig",
"15",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"OCTET STRING",
[
"octetStringSubType",
[
[
0,
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Each bit of this value set to '1' indicates a specific fault in the Media Gateway processor. Octets are numbered in the order in which they appear in the PDU. Bits are numbered from the most-significant leftmost bit in the octet (bit 0) to the least-significant rightmost bit (bit 7). Cajun numbering continues across octets, so that octet 1 bit 0 is called bit 8 in the Cajun scheme. That number is also shown below, with the octet value for each single bit set. Cajun Octet Octet bit# bit# value Meaning ----- ----- ----- ------- 0 0/0 0x80 Memory failure. 1 0/1 0x40 DHCP request failure. 2 0/2 0x20 Firmware download failure. 3 0/3 0x10 Software watchdog alert - MG processes restarting. 4 0/4 0x08 Internal Communications Controller expected but not present. 5 0/5 0x04 Internal Communications Controller automatic reset. 6 0/6 0x02 Media Gateway busy-out. 7 0/7 0x01 Configuration upload failure. 8 1/0 0x80 Primary controller not found. 9 1/1 0x40 No controller found. 10 1/2 0x20 Registration failure. 11 1/3 0x10 H.248 control link down. 12-13 1/4-5 Unused. 14 1/6 0x02 Maintenance test failure. 15 1/7 0x01 Maintenance test failure over threshold. 16 2/0 0x80 Configuration download failure. 17-23 2/0-7 Unused."
],
null,
null,
null,
null
]
}