Status in source: mandatory.
Names: locbrdgDefaultHoldTime
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"locbrdgDefaultHoldTime",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"After this time in seconds unacknowledged bpdus will be resent.This is the value stored in non volatile storage of the bridge, ans will used to initialise the locbrdgHoldTime after the next power up.\"",
"::=",
"{",
"locbrdg",
"26",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"After this time in seconds unacknowledged bpdus will be resent.This is the value stored in non volatile storage of the bridge, ans will used to initialise the locbrdgHoldTime after the next power up."
],
null,
null,
null,
null
]
}