The temperature of the indicated system temperature sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled
Sources for this description
Wired for Management and Quanta MIB copies in Fujitsu ServerView
OID reference
1.3.6.1.4.1.7244.1.1.1.0.1623
The temperature of the indicated system temperature sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled
Identification
{1 3 6 1 4 1 7244 1 1 1 0 1623}
The displayed source records contain one distinct definition. Compare its source records.
s31SysTempCriticalError TRAP-TYPE
ENTERPRISE s31MgmtAgent
VARIABLES {
s31TrapServerName,
s31TrapTime,
s31TrapObjectNumber,
s31SysTempSensorId
}
DESCRIPTION
"The temperature of the indicated system temperature sensor is out of tolerance range.
The system will shut down and power off if shutdown is enabled"
--#TYPE "Temperature critical"
--#SUMMARY "Temperature at system temperature sensor %d of blade chassis %s has reached the critical level."
--#ARGUMENTS { 3, 0 }
--#SEVERITY CRITICAL
--#TIMEINDEX 1
--#HELP "The temperature of the indicated system temperature sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled. Action: Check fan openings. Check fans. Reduce ambient temperature. Let the system cool down before restart. Do not operate system with removed cover. Proper airflow will not be guaranteed."
--#HELPTAG 0
--#STATE OPERATIONAL
::= 1623
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The temperature of the indicated system temperature sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled
Wired for Management and Quanta MIB copies in Fujitsu ServerView
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: unspecified.
Names: s31SysTempCriticalError
{
"smi_kind": "TRAP-TYPE",
"definition": [
"s31SysTempCriticalError",
"TRAP-TYPE",
"ENTERPRISE",
"s31MgmtAgent",
"VARIABLES",
"{",
"s31TrapServerName",
",",
"s31TrapTime",
",",
"s31TrapObjectNumber",
",",
"s31SysTempSensorId",
"}",
"DESCRIPTION",
"\"The temperature of the indicated system temperature sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled\"",
"::=",
"1623"
],
"syntax_tree": [
[
"objectIdentifier",
[
"s31MgmtAgent"
]
],
[
"VarTypes",
[
"s31TrapServerName",
"s31TrapTime",
"s31TrapObjectNumber",
"s31SysTempSensorId"
]
],
[
"DESCRIPTION",
"The temperature of the indicated system temperature sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled"
],
null
]
}Module: BLADE-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['Counter', 'Gauge', 'IpAddress', 'enterprises'], 'RFC1213-MIB': ['mib-2', 'DisplayString', 'PhysAddress']}Source data warning: MIB copy distributed in the official Fujitsu ServerView package. The BLADE-MIB comments identify Quanta; it uses enterprise number 7244. See the original file for its version. The original vendor distribution and applicability to a particular device or firmware have not been independently confirmed.
· Download ServerView partner MIB — S31.MIBRelated source files and packages:
Registration