Status of the power supply; ok: all units OK, number >= minimum degraded: one or more units failed, number OK >= minimum critical: number OK < minimum.
Sources for this description
Wired for Management and Quanta MIB copies in Fujitsu ServerView
OID reference
1.3.6.1.4.1.7244.1.1.1.3.2.1
Status of the power supply; ok: all units OK, number >= minimum degraded: one or more units failed, number OK >= minimum critical: number OK < minimum.
Identification
{1 3 6 1 4 1 7244 1 1 1 3 2 1}
| Value | Name |
|---|---|
| 1 | unknown |
| 2 | ok |
| 3 | degraded |
| 4 | critical |
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.7244.1.1.1.3.2.1.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
s31SysPowerSupplyStatus OBJECT-TYPE
SYNTAX INTEGER{
unknown(1),
ok(2),
degraded(3),
critical(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status of the power supply;
ok: all units OK, number >= minimum
degraded: one or more units failed, number OK >= minimum
critical: number OK < minimum."
::= { s31SysPowerSupply 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Status of the power supply; ok: all units OK, number >= minimum degraded: one or more units failed, number OK >= minimum critical: number OK < minimum.
Wired for Management and Quanta MIB copies in Fujitsu ServerView
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: s31SysPowerSupplyStatus
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"s31SysPowerSupplyStatus",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"unknown",
"(",
"1",
")",
",",
"ok",
"(",
"2",
")",
",",
"degraded",
"(",
"3",
")",
",",
"critical",
"(",
"4",
")",
"}",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Status of the power supply; ok: all units OK, number >= minimum degraded: one or more units failed, number OK >= minimum critical: number OK < minimum.\"",
"::=",
"{",
"s31SysPowerSupply",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"unknown",
1
],
[
"ok",
2
],
[
"degraded",
3
],
[
"critical",
4
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Status of the power supply; ok: all units OK, number >= minimum degraded: one or more units failed, number OK >= minimum critical: number OK < minimum."
],
null,
null,
null,
null
]
}Module: BLADE-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['Counter', 'Gauge', 'IpAddress', 'enterprises'], 'RFC1213-MIB': ['mib-2', 'DisplayString', 'PhysAddress']}Source data warning: MIB copy distributed in the official Fujitsu ServerView package. The BLADE-MIB comments identify Quanta; it uses enterprise number 7244. See the original file for its version. The original vendor distribution and applicability to a particular device or firmware have not been independently confirmed.
· Download ServerView partner MIB — S31.MIBRelated source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7244.1.1.1.3.2.2 | s31SysPowerSupplyRedundancy | 0 | 0 | |
| 1.3.6.1.4.1.7244.1.1.1.3.2.3 | s31SysPowerSupplyCtrl | 0 | 0 | |
| 1.3.6.1.4.1.7244.1.1.1.3.2.4 | s31SysPowerSupplyUnitTable | 1 | 11 | |
| 1.3.6.1.4.1.7244.1.1.1.3.2.5 | s31SysPowerSupplyOvpFailReaction | 0 | 0 | |
| 1.3.6.1.4.1.7244.1.1.1.3.2.6 | s31SysPowerSupplyOcpFailReaction | 0 | 0 | |
| 1.3.6.1.4.1.7244.1.1.1.3.2.7 | s31SysPowerSupplyRedundancyMode | 0 | 0 |