OID reference

pvcPort

1.3.6.1.4.1.727.7.2.10.2.1.4

Description

Frame Relay port used by the PVC. The port you select must be configured as a FR-USER port, using the port PROTOCOL parameter.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.727.7.2.10.2.1 (pvcEntry)
Node code
4
Node name
pvcPort
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.727.7.2.10.2.1.4
URN notation
urn:oid:1.3.6.1.4.1.727.7.2.10.2.1.4
Type
OBJECT-TYPE
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 727 7 2 10 2 1 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lucent(727) cleartrac7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lucent(727) netperformer7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) presticom(727) cleartrac7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) presticom(727) netperformer7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lucent(727) cleartrac7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lucent(727) netperformer7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) presticom(727) cleartrac7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) presticom(727) netperformer7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) lucent(727) cleartrac7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) lucent(727) netperformer7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) presticom(727) cleartrac7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) presticom(727) netperformer7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) lucent(727) cleartrac7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) lucent(727) netperformer7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) presticom(727) cleartrac7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) presticom(727) netperformer7(7) mgmt(2) pvc(10) pvcTable(2) pvcEntry(1) pvcPort(4)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/727/7/2/10/2/1/4
  • /ISO/Identified-Organization/6/1/4/1/727/7/2/10/2/1/4
  • /ISO/3/6/1/4/1/727/7/2/10/2/1/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/lucent/cleartrac7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/enterprise/lucent/netperformer7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/enterprise/presticom/cleartrac7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/enterprise/presticom/netperformer7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/enterprises/lucent/cleartrac7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/enterprises/lucent/netperformer7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/enterprises/presticom/cleartrac7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/enterprises/presticom/netperformer7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/lucent/cleartrac7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/lucent/netperformer7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/presticom/cleartrac7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/presticom/netperformer7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/vendor-objects/lucent/cleartrac7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/vendor-objects/lucent/netperformer7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/vendor-objects/presticom/cleartrac7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • /iso/identified-organization/dod/internet/private/vendor-objects/presticom/netperformer7/mgmt/pvc/pvcTable/pvcEntry/pvcPort
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In CLEARTRAC7-MIB, the row index pvcIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.727.7.2.10.2.1.4.<pvcIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.727.7.2.10.2.1.4

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Historical records

Additional source information

Information from OID Repository
Vendor: Verso Technologies Canada Inc. (previously was 'Presticom Inc.')
Module: CLEARTRAC7-MIB

[Automatically extracted from oidview.com]
Information from MIBdepot
pvcPort OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Frame Relay port used by the PVC.  The port you 
                        select must be configured as a FR-USER port, using 
                        the port PROTOCOL parameter."
                ::= { pvcEntry 4 }
Information from Circitor
pvcPort OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Frame Relay port used by the PVC.  The port you 
                        select must be configured as a FR-USER port, using 
                        the port PROTOCOL parameter."
                ::= { pvcEntry 4 }

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.727)

Dube Martin

Siblings (51)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.727.7.2.10.2.1.1 pvcIndex00 A unique value for each pvc. Its value ranges
between 1 and the value of pvcNumber.
1.3.6.1.4.1.727.7.2.10.2.1.2 pvcMode00 Operating mode of PVC.
1.3.6.1.4.1.727.7.2.10.2.1.3 pvcDlciAddress00 The DLCI address of the PVC, representing the
virtual connection identification for accessing
the remote unit. This address is p…
1.3.6.1.4.1.727.7.2.10.2.1.5 pvcUserPort00 Frame Relay port used by the PVC. The port you
select must be configured as a FR-USER port, using
the port PROTOCOL parameter.
1.3.6.1.4.1.727.7.2.10.2.1.6 pvcInfoRate00 PVC Committed Information Rate (CIR). The CIR
represents the data throughput that the network can
accept on this PVC. The CIR, …
1.3.6.1.4.1.727.7.2.10.2.1.9 pvcPriority00 Priority assigned to the PVC for the Spanning Tree
algorithm.
1.3.6.1.4.1.727.7.2.10.2.1.10 pvcCost00 The path cost assigned to the PVC for the Spanning Tree
algorithm. This indicates to the automatic single-route
bridge function …
1.3.6.1.4.1.727.7.2.10.2.1.11 pvcRemoteUnit00 Remote unit to which data from this PVC should be directed.
1.3.6.1.4.1.727.7.2.10.2.1.12 pvcTimeout-ms00 The wait for ACK timeout before retransmitting a frame
on the PVC.
1.3.6.1.4.1.727.7.2.10.2.1.13 pvcRetry00 Maximum number of successive retries before the PVC
connection is declared down.
1.3.6.1.4.1.727.7.2.10.2.1.14 pvcCompression00 Use compression on the PVC connection to the remote
unit. With compression, the available bandwidth is used
more efficiently. W…
1.3.6.1.4.1.727.7.2.10.2.1.15 pvcIpAddress00 IP address of the local PVC. This address is a 4-byte value
in dotted decimal representation, with a maximum value of 255
for eac…
1.3.6.1.4.1.727.7.2.10.2.1.16 pvcSubnetMask00 Subnet mask associated with the PVC's IP address. It is
configured like the IP address: a 4-byte value in dotted
decimal represen…
1.3.6.1.4.1.727.7.2.10.2.1.17 pvcMaxFrame00 Maximum frame size, in octets. This parameter
determines the largest datagram that can be sent
or received on the interface in o…
1.3.6.1.4.1.727.7.2.10.2.1.18 pvcBroadcastGroup00 0 and 1 apply to a pvc in pvcr mode only to
specify if its belongs or not to a broadcast group
1.3.6.1.4.1.727.7.2.10.2.1.19 pvcBrgConnection00 Bridge connection. Set this parameter to YES if the
RFC1490-compatible FRAD at the remote end requires
bridge frames. If bridge…
1.3.6.1.4.1.727.7.2.10.2.1.20 pvcIpConnection00 IP connection. Set this parameter to YES if the
RFC1490-compatible FRAD at the remote end requires
bridge frames. If IP data it…
1.3.6.1.4.1.727.7.2.10.2.1.21 pvcRemotePvc00 The remote PVC to which data from PVC is sent.
Specify the remote PVC number.
1.3.6.1.4.1.727.7.2.10.2.1.22 pvcPvcClass00 The priority class for data from this PVC. Classes
are defined according to bandwidth weight.
1.3.6.1.4.1.727.7.2.10.2.1.23 pvcNetworkPort00 The Frame Relay network port used by the transparent
PVC. The port you select must be configured as a
Frame Relay network port (…
1.3.6.1.4.1.727.7.2.10.2.1.24 pvcRingNumber00 The ring number of the remote Token-Ring LAN, required
for source routing of Token-Ring data via the unit.
1.3.6.1.4.1.727.7.2.10.2.1.25 pvcIpRip00 When this parameter is set to V1, the RIP routing
is done according to the RIP V1 standard. With
RIP V2, broadcast or multicast …
1.3.6.1.4.1.727.7.2.10.2.1.26 pvcBurstInfoRate00 PVC Burst Information Rate (BIR). The BIR
represents the data throughput that the network can
accept on this PVC when the networ…
1.3.6.1.4.1.727.7.2.10.2.1.27 pvcUserDlci00 The DLCI address of the PVC on the user side,
representing the virtual connection identification
on the frame relay interface.
1.3.6.1.4.1.727.7.2.10.2.1.28 pvcNetworkDlci00 The DLCI address of the PVC on the network side,
representing the virtual connection identification
on the frame relay interface.
1.3.6.1.4.1.727.7.2.10.2.1.29 pvcIpxRip00 if this parameter is enable, the unit will generate
IPX RIP frame on the port ( the one used by this pvc)
every minute, otherwise…
1.3.6.1.4.1.727.7.2.10.2.1.30 pvcIpxSap00 if this parameter is enable, the unit will generate
IPX SAP frame on the port ( the one used by this pvc)
every minute, otherwise…
1.3.6.1.4.1.727.7.2.10.2.1.31 pvcIpxNetNum00 This value identify the IPX network number which
the unit is connected to
1.3.6.1.4.1.727.7.2.10.2.1.32 pvcIpxConnection00 IPX connection. Set this parameter to YES if the
RFC1490-compatible FRAD at the remote end requires
bridge frames. If IPX data …
1.3.6.1.4.1.727.7.2.10.2.1.33 pvcType00 For PVCR mode only. This parameter defines the PVC
as a dedicated PVC or a backup PVC. The ANSWER type
is used for the PVC that…
1.3.6.1.4.1.727.7.2.10.2.1.34 pvcBackupCall-s00 Delay, in seconds, before activating the backup PVC when a
line failure has occurred on a dedicated link or PVC.
1.3.6.1.4.1.727.7.2.10.2.1.35 pvcBackupHang-s00 Delay, in seconds, before deactivating the backup WAN PVC
after the dedicated link or PVC has been restored.
1.3.6.1.4.1.727.7.2.10.2.1.36 pvcBackup00 Backup PVC can be configured to monitor and backup any
link or PCV that fails (ANY) or all links and PVCs (ALL).
1.3.6.1.4.1.727.7.2.10.2.1.37 pvcOspfEnable00 Indicates whether or not OSPF is enabled on this
PVC.
1.3.6.1.4.1.727.7.2.10.2.1.38 pvcOspfAreaId00 Identifies the area to which this PVC belongs.
1.3.6.1.4.1.727.7.2.10.2.1.39 pvcOspfTransitDelay00 pvcOspftransitDelay
1.3.6.1.4.1.727.7.2.10.2.1.40 pvcOspfRetransmitInt00 The number of seconds between like state advertisement
retransmissions for adjacencies belonging to this
PVC. Also used when ret…
1.3.6.1.4.1.727.7.2.10.2.1.41 pvcOspfHelloInt00 The length of time, in seconds, between the Hello
Packets that the router sends on the PVC.
This value is advertised in the route…
1.3.6.1.4.1.727.7.2.10.2.1.42 pvcOspfDeadInt00 After ceasing to hear a router's Hello Packets, the
number of seconds before its neighbors declare the
router down. This is also…
1.3.6.1.4.1.727.7.2.10.2.1.43 pvcOspfPassword00 This configured data allows the authentication
procedure to generate and/or verify the
authentication field in the OSPF header. …
1.3.6.1.4.1.727.7.2.10.2.1.44 pvcOspfMetricCost00 The cost of sending a packet on the PVC
expressed in the link state metric. This is
advertised as the link cost for this PVC
in t…
1.3.6.1.4.1.727.7.2.10.2.1.45 pvcProxyAddr00 This variable indicates in what slot of the remote unit
(i.e. the SDM-RX unit where this pvc goes) is the SNMP/NMS
proxy agent bo…
1.3.6.1.4.1.727.7.2.10.2.1.46 pvcLlcConnection00 IPX connection. Set this parameter to YES if the
RFC1490-compatible FRAD at the remote end requires
bridge frames. If IPX data …
1.3.6.1.4.1.727.7.2.10.2.1.47 pvcDialTimeout00 Wait time, in seconds, allowed to establish a backup pvc
using a dial phone number
1.3.6.1.4.1.727.7.2.10.2.1.48 pvcMaxChannels00 Indicates the maximum number of voice channels
permitted on this PVC.
1.3.6.1.4.1.727.7.2.10.2.1.49 pvcHuntForwardingAUnit00 Hunt forwarding group A Unit name. Unit name where a busy call for
hunt group A will be forwarded to
1.3.6.1.4.1.727.7.2.10.2.1.50 pvcHuntForwardingBUnit00 Hunt forwarding group B Unit name. Unit name where a busy call for
hunt group B will be forwarded to
1.3.6.1.4.1.727.7.2.10.2.1.51 pvcRemoteFpUnit00 Remote FP unit to which data from this PVC should be directed.
1.3.6.1.4.1.727.7.2.10.2.1.52 pvcIpRipTxRx00 This parameter allows RIP frames transmission only,
RIP frames reception only or both transmission and
reception of RIP frames.
1.3.6.1.4.1.727.7.2.10.2.1.53 pvcIpRipAuthType00 pvcIpRipAuthtype