Description 1
Battery Discharge Voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volt
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.7309.4.1.1.2
Battery Discharge Voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volt
Identification
{1 3 6 1 4 1 7309 4 1 1 2}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.7309.4.1.1.2.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
dcPwrSysDischargeVolts OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Battery Discharge Voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volt"
::= { dcPwrSysVariable 2 }dcPwrSysDischargeVolts OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This value indicates the present load voltage.
The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volts."
::= { dcPwrSysVariable 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Battery Discharge Voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volt
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
This value indicates the present load voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volts.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: dcPwrSysDischargeVolts
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"dcPwrSysDischargeVolts",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"-",
"1000000000",
".",
".",
"1000000000",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Battery Discharge Voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volt\"",
"::=",
"{",
"dcPwrSysVariable",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
-1000000000,
1000000000
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Battery Discharge Voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volt"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: Argus-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: Argus-MIB
Same published definition (formatting differs; exact original is in the source file)
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises']}Related source files and packages:
Status in source: current.
Names: dcPwrSysDischargeVolts
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"dcPwrSysDischargeVolts",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"-",
"1000000000",
".",
".",
"1000000000",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This value indicates the present load voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volts.\"",
"::=",
"{",
"dcPwrSysVariable",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
-1000000000,
1000000000
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This value indicates the present load voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volts."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: AlphaPowerSystem-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7309.4.1.1.1 | dcPwrSysChargeVolts | 0 | 0 | |
| 1.3.6.1.4.1.7309.4.1.1.3 | dcPwrSysChargeAmps | 0 | 0 | |
| 1.3.6.1.4.1.7309.4.1.1.4 | dcPwrSysDischargeAmps | 0 | 0 | |
| 1.3.6.1.4.1.7309.4.1.1.5 | dcPwrSysMajorAlarm | 0 | 0 | |
| 1.3.6.1.4.1.7309.4.1.1.6 | dcPwrSysMinorAlarm | 0 | 0 |