Status in source: current.
Names: ostFpgaUpdTable
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ostFpgaUpdTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"OstFpgaUpdEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"This table enables the chassis master's management entity to update the FPGA firmware of a module via a file residing on a module that was previously loaded by FTP. Steps to use entries in this table: 1) Wait for ostFpgaUpdReady value to be true. To do this do this sequence: a. an SNMP GET for both SnmpSetSerialNo and ostFpgaUpdReady objects (in same SNMP PDU). b. Check if value for ostFpgaUpdReady is true. - if not, wait x seconds, go to step a above. - if yes, save the value of SnmpSetSerialNo and go to step 2) below 2) Change ostFpgaUpdReady value from true to false to ensure no other management entity will use the service. In order to not disturb a possible other NMS do this by sending an SNMP SET for both SnmpSetSerialNo and ostFgaUpdgReady objects (in same SNMP PDU, and make sure SNmpSetSerialNo is the first varBind). For the SnmpSetSerialNo varBind, use the value that you obtained in step 1)a. This ensures that two cooperating NMSes will not interfere with each other. 3) Set ostFpgaUpdAction to write(1) value to initiate command operation. 4) Check the value of ostFpgaUpdLastStatus to find out if the operation was successfully completed. 5) Change the ostFpgaUpdReady value back to true to allow other management entities to use the table.\"",
"::=",
"{",
"ostFpgaUpd",
"1",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"OstFpgaUpdEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This table enables the chassis master's management entity to update the FPGA firmware of a module via a file residing on a module that was previously loaded by FTP. Steps to use entries in this table: 1) Wait for ostFpgaUpdReady value to be true. To do this do this sequence: a. an SNMP GET for both SnmpSetSerialNo and ostFpgaUpdReady objects (in same SNMP PDU). b. Check if value for ostFpgaUpdReady is true. - if not, wait x seconds, go to step a above. - if yes, save the value of SnmpSetSerialNo and go to step 2) below 2) Change ostFpgaUpdReady value from true to false to ensure no other management entity will use the service. In order to not disturb a possible other NMS do this by sending an SNMP SET for both SnmpSetSerialNo and ostFgaUpdgReady objects (in same SNMP PDU, and make sure SNmpSetSerialNo is the first varBind). For the SnmpSetSerialNo varBind, use the value that you obtained in step 1)a. This ensures that two cooperating NMSes will not interfere with each other. 3) Set ostFpgaUpdAction to write(1) value to initiate command operation. 4) Check the value of ostFpgaUpdLastStatus to find out if the operation was successfully completed. 5) Change the ostFpgaUpdReady value back to true to allow other management entities to use the table."
],
null,
null,
null,
null
]
}