Status in source: current.
Names: ostY1731RealTimeResultsCcmTable
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ostY1731RealTimeResultsCcmTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"OstY1731RealTimeResultsCcmEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"This table provides read only access to the last 900 real time measurements for Y.1731 'dual ended loss/availability (CCM)' probes. Each table row represents one real time measurement. The ostY1731RtrIntrvlNum table index selects a given real time measurement. The rate at which the real time measurements are made is set by the probe interval. The following table specifies the relationship of the probe interval setting and the total time represented by the 900 real time measurements: +----------------+-------------+ | Probe Interval | Total Time | +----------------+-------------+ | 100 ms | 90 seconds | | 1 second | 15 minutes | | 10 seconds | 150 minutes | | 1 minute | 15 hours | | 10 minutes | 150 hours | +----------------+-------------+ \"",
"::=",
"{",
"ostY1731RealTimeResults",
"2",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"OstY1731RealTimeResultsCcmEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This table provides read only access to the last 900 real time measurements for Y.1731 'dual ended loss/availability (CCM)' probes. Each table row represents one real time measurement. The ostY1731RtrIntrvlNum table index selects a given real time measurement. The rate at which the real time measurements are made is set by the probe interval. The following table specifies the relationship of the probe interval setting and the total time represented by the 900 real time measurements: +----------------+-------------+ | Probe Interval | Total Time | +----------------+-------------+ | 100 ms | 90 seconds | | 1 second | 15 minutes | | 10 seconds | 150 minutes | | 1 minute | 15 hours | | 10 minutes | 150 hours | +----------------+-------------+"
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: OMNITRON-Y1731-MIB
See published definition above
Module imports
{'NTP-MIB': ['NTPTimeStamp'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'OMNITRON-TC-MIB': ['omnitron', 'OstVlanId', 'OstEvcNameString', 'OstFrameCount64', 'OstProbeNameString'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMaintDomainName', 'Dot1agCfmMDLevelOrNone', 'Dot1agCfmMaintAssocName'], 'OMNITRON-EXT-MIB': ['ostModuleIndex']}
· Download OMNITRON-Y1731-MIB
Related source files and packages: