Status in source: current.
Names: ostY1731Pmr1DmTable
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ostY1731Pmr1DmTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"OstY1731Pmr1DmEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"This table provides read only access to the last 24 hours of performance metrics and to the last 7 days of performance metrics for Y.1731 '1-way delay/variation (1DM)' probes. Frame delay and frame delay variation values are in millisecond resolution. For the last 24 hours of performance measurement buckets, each table row represents the performance measurements for 1 bucket period. The ostY1731PmrIntrvlNum table index selects a given bucket. Performance metric measurements are calculated over a period specified by the Bucket Period setting, which is from 1 to 60 minutes. For the last 7 days of performance metrics, there is only one row which represents the accumulated performance metrics for that 24 hour period. The following table specifies the number of buckets for a 24 hour period based on the Bucket Period setting. +---------------+--------------+ | Bucket Period | # of buckets | | (minutes) | for 24 hours | +---------------+--------------+ | 1 | 1440 | +---------------+--------------+ | 10 | 144 | +---------------+--------------+ | 15 | 96 | +---------------+--------------+ | 30 | 48 | +---------------+--------------+ | 60 | 24 | +---------------+--------------+ The following table specifies the number of real time measurements used to compute a performance measurement based on the probe interval and various bucket periods. The number of real time measurements specified are not stored, only the last 900 are accessible from the MIB, see ostY1731RealTimeResults. +------------------------+ | Bucket Period (minutes)| +----------------+-------+--------+-------+ | Probe Interval | 1 | 15 | 60 | +----------------+-------+--------+-------+ | 100 ms | 600 | 9000 | 36000 | +----------------+-------+--------+-------+ | 1 second | 60 | 900 | 3600 | +----------------+-------+--------+-------+ | 10 seconds | 6 | 90 | 360 | +----------------+-------+--------+-------+ | 1 minute | 1 | 15 | 60 | +----------------+-------+--------+-------+ | 10 minutes | 0.1 | 2.5 | 6 | +----------------+-------+--------+-------+ \"",
"::=",
"{",
"ostY1731PerfMetricsResults",
"3",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"OstY1731Pmr1DmEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This table provides read only access to the last 24 hours of performance metrics and to the last 7 days of performance metrics for Y.1731 '1-way delay/variation (1DM)' probes. Frame delay and frame delay variation values are in millisecond resolution. For the last 24 hours of performance measurement buckets, each table row represents the performance measurements for 1 bucket period. The ostY1731PmrIntrvlNum table index selects a given bucket. Performance metric measurements are calculated over a period specified by the Bucket Period setting, which is from 1 to 60 minutes. For the last 7 days of performance metrics, there is only one row which represents the accumulated performance metrics for that 24 hour period. The following table specifies the number of buckets for a 24 hour period based on the Bucket Period setting. +---------------+--------------+ | Bucket Period | # of buckets | | (minutes) | for 24 hours | +---------------+--------------+ | 1 | 1440 | +---------------+--------------+ | 10 | 144 | +---------------+--------------+ | 15 | 96 | +---------------+--------------+ | 30 | 48 | +---------------+--------------+ | 60 | 24 | +---------------+--------------+ The following table specifies the number of real time measurements used to compute a performance measurement based on the probe interval and various bucket periods. The number of real time measurements specified are not stored, only the last 900 are accessible from the MIB, see ostY1731RealTimeResults. +------------------------+ | Bucket Period (minutes)| +----------------+-------+--------+-------+ | Probe Interval | 1 | 15 | 60 | +----------------+-------+--------+-------+ | 100 ms | 600 | 9000 | 36000 | +----------------+-------+--------+-------+ | 1 second | 60 | 900 | 3600 | +----------------+-------+--------+-------+ | 10 seconds | 6 | 90 | 360 | +----------------+-------+--------+-------+ | 1 minute | 1 | 15 | 60 | +----------------+-------+--------+-------+ | 10 minutes | 0.1 | 2.5 | 6 | +----------------+-------+--------+-------+"
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: OMNITRON-Y1731-MIB
See published definition above
Module imports
{'NTP-MIB': ['NTPTimeStamp'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'OMNITRON-TC-MIB': ['omnitron', 'OstVlanId', 'OstEvcNameString', 'OstFrameCount64', 'OstProbeNameString'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMaintDomainName', 'Dot1agCfmMDLevelOrNone', 'Dot1agCfmMaintAssocName'], 'OMNITRON-EXT-MIB': ['ostModuleIndex']}
· Download OMNITRON-Y1731-MIB
Related source files and packages: