If the clock input controller recovers a clock from a port , this variable indicates the TDM Port. Otherwise, it must be set to zero.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.738.1.5.111.1.6.1.5
If the clock input controller recovers a clock from a port , this variable indicates the TDM Port. Otherwise, it must be set to zero.
Identification
{1 3 6 1 4 1 738 1 5 111 1 6 1 5}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: prvtCESCICModuleId, prvtCESCICNumber.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.738.1.5.111.1.6.1.5
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
prvtCESCICTdmPort OBJECT-TYPE
SYNTAX Integer32 (0..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the clock input controller recovers a clock
from a port , this variable indicates the
TDM Port. Otherwise, it must
be set to zero."
::= {prvtCESCICEntry 5}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
If the clock input controller recovers a clock from a port , this variable indicates the TDM Port. Otherwise, it must be set to zero.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: prvtCESCICTdmPort
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"prvtCESCICTdmPort",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"4",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"If the clock input controller recovers a clock from a port , this variable indicates the TDM Port. Otherwise, it must be set to zero.\"",
"::=",
"{",
"prvtCESCICEntry",
"5",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
4
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"If the clock input controller recovers a clock from a port , this variable indicates the TDM Port. Otherwise, it must be set to zero."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: PRVT-CES-MIB
See published definition above
{'DS1-MIB': ['dsx1ConfigEntry'], 'SNMPv2-TC': ['TimeStamp', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'IpAddress', 'Gauge32', 'Integer32', 'Unsigned32', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'PRVT-SWITCH-MIB': ['switch']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.738.1.5.111.1.6.1.1 | prvtCESCICModuleId | 0 | 0 | |
| 1.3.6.1.4.1.738.1.5.111.1.6.1.2 | prvtCESCICNumber | 0 | 0 | |
| 1.3.6.1.4.1.738.1.5.111.1.6.1.3 | prvtCESCICClockNumber | 0 | 0 | |
| 1.3.6.1.4.1.738.1.5.111.1.6.1.4 | prvtCESCICMode | 0 | 0 | |
| 1.3.6.1.4.1.738.1.5.111.1.6.1.6 | prvtCESCICCircuit | 0 | 0 | |
| 1.3.6.1.4.1.738.1.5.111.1.6.1.7 | prvtCESCICStatus | 0 | 0 | |
| 1.3.6.1.4.1.738.1.5.111.1.6.1.8 | prvtCESCICState | 0 | 0 |