Sonet VT alarms entry
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.738.1.5.114.1.5.5.1
Sonet VT alarms entry
Identification
{1 3 6 1 4 1 738 1 5 114 1 5 5 1}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
prvtSonetVTAlarmsEntry OBJECT-TYPE
SYNTAX PrvtSonetVTAlarmsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sonet VT alarms entry"
INDEX { ifIndex }
::= { prvtSonetVTAlarmsTable 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Sonet VT alarms entry
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: prvtSonetVTAlarmsEntry
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"prvtSonetVTAlarmsEntry",
"OBJECT-TYPE",
"SYNTAX",
"PrvtSonetVTAlarmsEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"Sonet VT alarms entry\"",
"INDEX",
"{",
"ifIndex",
"}",
"::=",
"{",
"prvtSonetVTAlarmsTable",
"1",
"}"
],
"syntax_tree": [
[
"row",
"PrvtSonetVTAlarmsEntry"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Sonet VT alarms entry"
],
null,
null,
[
"INDEX",
[
[
0,
"ifIndex"
]
]
],
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: PRVT-STATISTICS-CES-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'DS1-MIB': ['dsx1CurrentEntry', 'dsx1IntervalEntry', 'dsx1TotalEntry', 'dsx1FarEndCurrentEntry', 'dsx1FarEndIntervalEntry', 'dsx1FarEndTotalEntry'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SONET-MIB': ['sonetSectionCurrentEntry', 'sonetSectionIntervalEntry', 'sonetLineCurrentEntry', 'sonetLineIntervalEntry', 'sonetFarEndLineCurrentEntry', 'sonetFarEndLineIntervalEntry', 'sonetPathCurrentEntry', 'sonetPathIntervalEntry', 'sonetFarEndPathCurrentEntry', 'sonetFarEndPathIntervalEntry', 'sonetVTCurrentEntry', 'sonetVTIntervalEntry', 'sonetFarEndVTCurrentEntry', 'sonetFarEndVTIntervalEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE'], 'PRVT-SWITCH-MIB': ['switch'], 'PerfHist-TC-MIB': ['PerfCurrentCount', 'PerfIntervalCount', 'PerfTotalCount']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.738.1.5.114.1.5.5.1.1 | prvtSonetVTAlarmType | 0 | 0 | |
| 1.3.6.1.4.1.738.1.5.114.1.5.5.1.2 | prvtSonetVTAlarmStatus | 0 | 0 |