The format for a VTS object instance is shelf/slot/port/vts (1 byte each).
Sources for this description
Nokia networking MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.7483.2.1.3.2.4.6.1.1
The format for a VTS object instance is shelf/slot/port/vts (1 byte each).
Identification
{1 3 6 1 4 1 7483 2 1 3 2 4 6 1 1}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: tnVtsAlarmCategoryObjectId, tnVtsAlarmCategoryDirection, tnVtsAlarmCategoryEntityType, tnVtsAlarmCategoryCondition.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
tnVtsAlarmCategoryObjectId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The format for a VTS object instance is
shelf/slot/port/vts (1 byte each)."
::= { tnPerVtsObjectAlarmCategoryConfigEntry 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The format for a VTS object instance is shelf/slot/port/vts (1 byte each).
Nokia networking MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: tnVtsAlarmCategoryObjectId
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tnVtsAlarmCategoryObjectId",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"The format for a VTS object instance is shelf/slot/port/vts (1 byte each).\"",
"::=",
"{",
"tnPerVtsObjectAlarmCategoryConfigEntry",
"1",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The format for a VTS object instance is shelf/slot/port/vts (1 byte each)."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Nokia support.
Module: TROPIC-LOG-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus'], 'TROPIC-TC': ['TnTrapCategory', 'TnEntityType', 'TnCondition', 'AluWdmAsapType'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'IpAddress', 'Unsigned32', 'Integer32', 'OBJECT-IDENTITY'], 'TN-SAP-MIB': ['tnSapPortId', 'tnSapEncapValue'], 'TN-SDP-MIB': ['sdpBindId'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'TN-MPLS-MIB': ['vRtrMplsLspIndex'], 'TN-SERV-MIB': ['tnSvcId'], 'TN-VRTR-MIB': ['vRtrID', 'vRtrIfIndex'], 'TN-RMD-IF-MIB': ['tnRmdIfIndex', 'tnRmdIfMauIndex', 'TnRmdNimDirection'], 'TN-MPLS-TP-MIB': ['vRtrMplsTpLspPathIndex'], 'TN-RMD-CFM-MIB': ['tnRmdCfmMepNumber'], 'TN-ETH-RING-MIB': ['tnEthRingIndex'], 'TN-OAM-TEST-MIB': ['tnOamSaaCtlTestIndex'], 'TN-RMD-TSOP-MIB': ['tnRmdTsopIwfChannelNumber'], 'IEEE8021-CFM-MIB': ['dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier'], 'TN-RMD-SYSTEM-MIB': ['tnRmdSystemId'], 'TROPIC-GLOBAL-REG': ['tnSystemModules', 'tnLogMIB'], 'TROPIC-SYSTEM-MIB': ['tnSysSwitchId'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7483.2.1.3.2.4.6.1.2 | tnVtsAlarmCategoryDirection | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.1.3.2.4.6.1.3 | tnVtsAlarmCategoryEntityType | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.1.3.2.4.6.1.4 | tnVtsAlarmCategoryCondition | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.1.3.2.4.6.1.5 | tnPerVtsObjectAlarmCategory | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.1.3.2.4.6.1.6 | tnPerVtsObjectAlarmEntityTypeCategory | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.1.3.2.4.6.1.7 | tnPerVtsObjectAlarmDefaultCategory | 0 | 0 |