DB synchronization direction between RMU and OSU. This object is not applicable for the managing OSU, and has fixed value osuToRmu(1).
Sources for this description
Nokia networking MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.7483.2.2.6.1.1.1.1.11
DB synchronization direction between RMU and OSU. This object is not applicable for the managing OSU, and has fixed value osuToRmu(1).
Identification
{1 3 6 1 4 1 7483 2 2 6 1 1 1 1 11}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
tnVwmMsShelfDbSyncDirection OBJECT-TYPE
SYNTAX TropicVwmMsDbSyncDirection
MAX-ACCESS read-create
STATUS current
DESCRIPTION "DB synchronization direction between RMU and OSU.
This object is not applicable for the managing OSU,
and has fixed value osuToRmu(1)."
::= { tnVwmMsShelfEntry 11 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
DB synchronization direction between RMU and OSU. This object is not applicable for the managing OSU, and has fixed value osuToRmu(1).
Nokia networking MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: tnVwmMsShelfDbSyncDirection
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tnVwmMsShelfDbSyncDirection",
"OBJECT-TYPE",
"SYNTAX",
"TropicVwmMsDbSyncDirection",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"DB synchronization direction between RMU and OSU. This object is not applicable for the managing OSU, and has fixed value osuToRmu(1).\"",
"::=",
"{",
"tnVwmMsShelfEntry",
"11",
"}"
],
"syntax_tree": [
[
"row",
"TropicVwmMsDbSyncDirection"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"DB synchronization direction between RMU and OSU. This object is not applicable for the managing OSU, and has fixed value osuToRmu(1)."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Nokia support.
Module: TROPIC-VWMMS-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero', 'ifEntry', 'ifIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DateAndTime', 'DisplayString', 'MacAddress', 'RowStatus', 'TimeInterval', 'TruthValue'], 'TROPIC-TC': ['TnCondition', 'TnSfpType', 'TnCommand'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'Counter32', 'Counter64', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'IEEE8021-CFM-MIB': ['VlanIdOrNone'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressPrefixLength', 'InetAddressType', 'InetPortNumber'], 'ITU-ALARM-TC-MIB': ['ItuPerceivedSeverity'], 'TROPIC-GLOBAL-REG': ['tnVwmMsMIB', 'tnVwmMsModules', 'tropicEmptyCard', 'tropicEmptyShelf'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'TROPIC-SOFTWARE-MIB': ['TropicSwControl', 'TropicSwLastOperationStatus'], 'TROPIC-USERMGMT-MIB': ['tnUserEntry'], 'TROPIC-NOTIFICATION-MIB': ['tnTrapCategory', 'tnTrapDescr', 'tnTrapData', 'tnTrapTime'], 'TROPIC-GENERIC-NOTIFICATION-MIB': ['tnGenericTrapSeqNumber', 'tnGenericTrapObject', 'tnGenericTrapObjectInstance', 'tnGenericTrapTime', 'tnGenericTrapCategory', 'tnGenericTrapDateAndTime', 'tnGenericTrapConfigurationChangeCounter']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.1 | tnVwmMsShelfIndex | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.2 | tnVwmMsShelfName | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.3 | tnVwmMsShelfDescr | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.4 | tnVwmMsShelfProgrammedType | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.5 | tnVwmMsShelfPresentType | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.6 | tnVwmMsShelfLampTest | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.7 | tnVwmMsShelfSerialNumber | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.8 | tnVwmMsShelfLocation | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.9 | tnVwmMsShelfLocationCode | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.10 | tnVwmMsShelfManagementMode | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.12 | tnVwmMsShelfConnectionState | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.13 | tnVwmMsShelfSynchState | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.14 | tnVwmMsShelfLatitude | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.15 | tnVwmMsShelfLongitude | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.16 | tnVwmMsShelfAltitude | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.1.1.1.1.17 | tnVwmMsShelfTypeString | 0 | 0 |