VWMMS table for Digital Diagnostics Monitoring (DDM) Data of optical SFPs.
Sources for this description
Nokia networking MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.7483.2.2.6.2.1.14
VWMMS table for Digital Diagnostics Monitoring (DDM) Data of optical SFPs.
Identification
{1 3 6 1 4 1 7483 2 2 6 2 1 14}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
tnVwmMsDdmDataTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnVwmMsDdmDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "VWMMS table for Digital Diagnostics Monitoring
(DDM) Data of optical SFPs."
::= { tnVwmMsInterfaceObjects 14 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
VWMMS table for Digital Diagnostics Monitoring (DDM) Data of optical SFPs.
Nokia networking MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: tnVwmMsDdmDataTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tnVwmMsDdmDataTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"TnVwmMsDdmDataEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"VWMMS table for Digital Diagnostics Monitoring (DDM) Data of optical SFPs.\"",
"::=",
"{",
"tnVwmMsInterfaceObjects",
"14",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"TnVwmMsDdmDataEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"VWMMS table for Digital Diagnostics Monitoring (DDM) Data of optical SFPs."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Nokia support.
Module: TROPIC-VWMMS-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero', 'ifEntry', 'ifIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DateAndTime', 'DisplayString', 'MacAddress', 'RowStatus', 'TimeInterval', 'TruthValue'], 'TROPIC-TC': ['TnCondition', 'TnSfpType', 'TnCommand'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'Counter32', 'Counter64', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'IEEE8021-CFM-MIB': ['VlanIdOrNone'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressPrefixLength', 'InetAddressType', 'InetPortNumber'], 'ITU-ALARM-TC-MIB': ['ItuPerceivedSeverity'], 'TROPIC-GLOBAL-REG': ['tnVwmMsMIB', 'tnVwmMsModules', 'tropicEmptyCard', 'tropicEmptyShelf'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'TROPIC-SOFTWARE-MIB': ['TropicSwControl', 'TropicSwLastOperationStatus'], 'TROPIC-USERMGMT-MIB': ['tnUserEntry'], 'TROPIC-NOTIFICATION-MIB': ['tnTrapCategory', 'tnTrapDescr', 'tnTrapData', 'tnTrapTime'], 'TROPIC-GENERIC-NOTIFICATION-MIB': ['tnGenericTrapSeqNumber', 'tnGenericTrapObject', 'tnGenericTrapObjectInstance', 'tnGenericTrapTime', 'tnGenericTrapCategory', 'tnGenericTrapDateAndTime', 'tnGenericTrapConfigurationChangeCounter']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7483.2.2.6.2.1.14.1 | tnVwmMsDdmDataEntry | 2 | 2 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7483.2.2.6.2.1.1 | tnVwmMsIfTable | 1 | 8 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.2 | tnVwmMsSfpConfigTable | 1 | 3 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.3 | tnVwmMsSfpInfoTable | 1 | 31 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.4 | tnVwmMsCdrChannelTable | 1 | 9 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.5 | tnVwmMsPowerIfTable | 1 | 3 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.6 | tnVwmMsExtAlmIfTable | 1 | 7 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.7 | tnVwmMsExtAnalogIfTable | 1 | 4 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.8 | tnVwmMsExtAnalogIfInfoTable | 1 | 3 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.9 | tnVwmMsExtCtrlIfTable | 1 | 5 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.10 | tnVwmMsRflmIfTable | 1 | 2 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.11 | tnVwmMsPrbsTest | 4 | 4 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.12 | tnVwmMsPrbsTestResultTable | 1 | 6 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.13 | tnVwmMsIfLoopbackTable | 1 | 3 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.15 | tnVwmMsPwrIfTable | 1 | 3 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.16 | tnVwmMsIfMonitorTable | 1 | 3 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.17 | tnVwmMsIfLosPropagationTable | 1 | 4 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.18 | tnVwmMsIfOptPwrThresholdsTable | 1 | 3 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.19 | tnVwmMsUserDataIfTable | 1 | 5 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.20 | tnVwmMsUserDataTpidTable | 1 | 2 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.21 | tnVwmMsAmplifierPortConfigTable | 1 | 3 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.22 | tnVwmMsAmplifierPortInfoTable | 1 | 7 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.23 | tnVwmMsOpticalPortConfigTable | 1 | 8 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.24 | tnVwmMsOpticalPortInfoTable | 1 | 5 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.25 | tnVwmMsAmplifierPortPumpInfoTable | 1 | 9 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.26 | tnVwmMsSfpProfileTable | 1 | 3 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.27 | tnVwmMsSfpProfileRateTable | 1 | 4 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.28 | tnVwmMsShelfSfpProfileTable | 1 | 2 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.29 | tnVwmMsSfpProfilePnCreateDeleteProfileIndex | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.30 | tnVwmMsSfpProfilePnCreateDeletePn | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.31 | tnVwmMsSfpProfilePnCreateRate | 0 | 0 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.32 | tnVwmMsSfpProfilePnRateTable | 1 | 3 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.33 | tnVwmMsSfpProfilePnRateCapabilityTable | 1 | 2 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.34 | tnVwmMsIfOtdrTable | 1 | 9 | |
| 1.3.6.1.4.1.7483.2.2.6.2.1.35 | tnVwmMsIfOtdrResultTable | 1 | 5 |