This object specifies the maximum number of consecutive SDP Echo Request messages that can be unacknowledged before the keep-alive protocol reports a fault.
Sources for this description
Nokia networking MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.7483.6.1.2.4.4.3.1.15
This object specifies the maximum number of consecutive SDP Echo Request messages that can be unacknowledged before the keep-alive protocol reports a fault.
Identification
{1 3 6 1 4 1 7483 6 1 2 4 4 3 1 15}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: tnSysSwitchId, sdpId.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.7483.6.1.2.4.4.3.1.15
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
sdpKeepAliveMaxDropCount OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object specifies the maximum number of
consecutive SDP Echo Request messages that can
be unacknowledged before the keep-alive
protocol reports a fault."
DEFVAL { 3 }
::= { sdpInfoEntry 15 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This object specifies the maximum number of consecutive SDP Echo Request messages that can be unacknowledged before the keep-alive protocol reports a fault.
Nokia networking MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: sdpKeepAliveMaxDropCount
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sdpKeepAliveMaxDropCount",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"1",
".",
".",
"5",
")",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"This object specifies the maximum number of consecutive SDP Echo Request messages that can be unacknowledged before the keep-alive protocol reports a fault.\"",
"DEFVAL",
"{",
"3",
"}",
"::=",
"{",
"sdpInfoEntry",
"15",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
1,
5
]
]
]
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object specifies the maximum number of consecutive SDP Echo Request messages that can be unacknowledged before the keep-alive protocol reports a fault."
],
null,
null,
null,
[
"DEFVAL",
3
]
]
}Vendor MIB copy from the Observium Community archive. Nokia support.
Module: TN-SDP-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TimeStamp', 'TruthValue'], 'TN-TC-MIB': ['ServiceAdminStatus', 'TmnxServId', 'TmnxCustId', 'TNamedItem', 'SdpBindId', 'TNamedItemOrEmpty', 'TmnxVRtrMplsLspID', 'TmnxOperState', 'TmnxIgmpVersion', 'TmnxEnabledDisabled', 'TItemDescription', 'TCpmProtPolicyID', 'TmnxVPNRouteDistinguisher', 'TmnxBsxTransitIpPolicyIdOrZero', 'TmnxBsxTransPrefPolicyIdOrZero', 'TmnxBsxAarpIdOrZero', 'TmnxBsxAarpServiceRefType', 'TmnxPortID', 'TmnxVcId', 'TSdpIngressPolicyID', 'TSdpEgressPolicyID', 'TQosQGrpInstanceIDorZero', 'TmnxMplsTpGlobalID', 'TmnxMplsTpNodeID', 'ServObjDesc', 'TFilterID', 'TFdbTableSizeProfileID'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'IpAddress', 'Counter64'], 'TN-SERV-MIB': ['tnServObjs', 'tnSvcId', 'ServObjName', 'VpnId', 'SdpId', 'SdpBindVcType', 'LspIdList', 'TlsLimitMacMove', 'SdpBindBandwidth', 'L2RouteOrigin', 'PWTemplateId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'TROPIC-GLOBAL-REG': ['tnSRMIBModules'], 'TROPIC-SYSTEM-MIB': ['tnSysSwitchId']}Related source files and packages:
Registration