There is one CFM Stack table per bridge. It permits the retrieval of information about the Maintenance Points configured on any given interface.
Sources for this description
Nokia networking MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.7483.6.1.2.52.1.2
There is one CFM Stack table per bridge. It permits the retrieval of information about the Maintenance Points configured on any given interface.
Identification
{1 3 6 1 4 1 7483 6 1 2 52 1 2}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
tnDot1agCfmStackTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnDot1agCfmStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"There is one CFM Stack table per bridge. It permits
the retrieval of information about the Maintenance Points
configured on any given interface.
"
REFERENCE
"802.1ag clauses 12.14.2"
::= { tnDot1agCfmStack 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
There is one CFM Stack table per bridge. It permits the retrieval of information about the Maintenance Points configured on any given interface.
Nokia networking MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: tnDot1agCfmStackTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tnDot1agCfmStackTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"TnDot1agCfmStackEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"There is one CFM Stack table per bridge. It permits the retrieval of information about the Maintenance Points configured on any given interface. \"",
"REFERENCE",
"\"802.1ag clauses 12.14.2\"",
"::=",
"{",
"tnDot1agCfmStack",
"2",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"TnDot1agCfmStackEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"There is one CFM Stack table per bridge. It permits the retrieval of information about the Maintenance Points configured on any given interface."
],
[
"REFERENCE",
"802.1ag clauses 12.14.2"
],
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Nokia support.
Module: TN-IEEE8021-CFM-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'MacAddress', 'TruthValue'], 'TN-TC-MIB': ['TmnxServId', 'TmnxEnabledDisabled', 'TNamedItem'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'Unsigned32', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32', 'Gauge32'], 'TN-SERV-MIB': ['SdpId'], 'IEEE8021-CFM-MIB': ['dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'Dot1agCfmMDLevel', 'Dot1agCfmMpDirection', 'Dot1agCfmMepIdOrZero', 'dot1agCfmMepEntry', 'Dot1agCfmMepId', 'dot1agCfmMepTransmitLbmDestMacAddress', 'dot1agCfmMepTransmitLtmSeqNumber', 'Dot1agCfmCcmInterval', 'dot1agCfmMaNetEntry', 'dot1agCfmMaMepListEntry'], 'TROPIC-GLOBAL-REG': ['tnSRMIBModules', 'tnSRObjs', 'tnSRNotifyPrefix'], 'TROPIC-SYSTEM-MIB': ['tnSysSwitchId']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7483.6.1.2.52.1.2.1 | tnDot1agCfmStackEntry | 9 | 9 |