The value of tnRmdIfDdmExtCalTemperatureSlope indicates the T(Slope) value as specified in Table 3.16 in the SFF Committee Standard's document SFF-8472 Rev 10.2.
Sources for this description
Nokia networking MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.7483.6.4.1.3.7.1.37
The value of tnRmdIfDdmExtCalTemperatureSlope indicates the T(Slope) value as specified in Table 3.16 in the SFF Committee Standard's document SFF-8472 Rev 10.2.
Identification
{1 3 6 1 4 1 7483 6 4 1 3 7 1 37}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: tnSysSwitchId, tnRmdSystemId, tnRmdIfIndex, tnRmdIfMauIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.7483.6.4.1.3.7.1.37
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
tnRmdIfDdmExtCalTemperatureSlope OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnRmdIfDdmExtCalTemperatureSlope indicates the
T(Slope) value as specified in Table 3.16 in the SFF
Committee Standard's document SFF-8472 Rev 10.2."
REFERENCE "SFF-8472 Rev 10.2"
::= { tnRmdIfDdmEntry 37 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The value of tnRmdIfDdmExtCalTemperatureSlope indicates the T(Slope) value as specified in Table 3.16 in the SFF Committee Standard's document SFF-8472 Rev 10.2.
Nokia networking MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: tnRmdIfDdmExtCalTemperatureSlope
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tnRmdIfDdmExtCalTemperatureSlope",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"65535",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tnRmdIfDdmExtCalTemperatureSlope indicates the T(Slope) value as specified in Table 3.16 in the SFF Committee Standard's document SFF-8472 Rev 10.2.\"",
"REFERENCE",
"\"SFF-8472 Rev 10.2\"",
"::=",
"{",
"tnRmdIfDdmEntry",
"37",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
65535
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tnRmdIfDdmExtCalTemperatureSlope indicates the T(Slope) value as specified in Table 3.16 in the SFF Committee Standard's document SFF-8472 Rev 10.2."
],
[
"REFERENCE",
"SFF-8472 Rev 10.2"
],
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Nokia support.
Module: TN-RMD-IF-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex', 'IANAifType'], 'SNMPv2-TC': ['MacAddress', 'TruthValue', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'Counter64'], 'IEEE8021-CFM-MIB': ['VlanIdOrNone'], 'TN-RMD-SYSTEM-MIB': ['tnRmdSystemId'], 'TROPIC-GLOBAL-REG': ['tnRmdObjs', 'tnRmdMIBModules'], 'TROPIC-SYSTEM-MIB': ['tnSysSwitchId'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.1 | tnRmdIfDdmTemperature | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.2 | tnRmdIfDdmTempLowWarning | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.3 | tnRmdIfDdmTempLowAlarm | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.4 | tnRmdIfDdmTempHiWarning | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.5 | tnRmdIfDdmTempHiAlarm | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.6 | tnRmdIfDdmSupplyVoltage | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.7 | tnRmdIfDdmSupplyVoltageLowWarning | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.8 | tnRmdIfDdmSupplyVoltageLowAlarm | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.9 | tnRmdIfDdmSupplyVoltageHiWarning | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.10 | tnRmdIfDdmSupplyVoltageHiAlarm | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.11 | tnRmdIfDdmTxBiasCurrent | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.12 | tnRmdIfDdmTxBiasCurrentLowWarning | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.13 | tnRmdIfDdmTxBiasCurrentLowAlarm | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.14 | tnRmdIfDdmTxBiasCurrentHiWarning | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.15 | tnRmdIfDdmTxBiasCurrentHiAlarm | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.16 | tnRmdIfDdmTxOutputPower | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.17 | tnRmdIfDdmTxOutputPowerLowWarning | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.18 | tnRmdIfDdmTxOutputPowerLowAlarm | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.19 | tnRmdIfDdmTxOutputPowerHiWarning | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.20 | tnRmdIfDdmTxOutputPowerHiAlarm | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.21 | tnRmdIfDdmRxOpticalPower | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.22 | tnRmdIfDdmRxOpticalPowerLowWarning | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.23 | tnRmdIfDdmRxOpticalPowerLowAlarm | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.24 | tnRmdIfDdmRxOpticalPowerHiWarning | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.25 | tnRmdIfDdmRxOpticalPowerHiAlarm | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.26 | tnRmdIfDdmRxOpticalPowerType | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.27 | tnRmdIfDdmExternallyCalibrated | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.28 | tnRmdIfDdmExtCalRxPower4 | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.29 | tnRmdIfDdmExtCalRxPower3 | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.30 | tnRmdIfDdmExtCalRxPower2 | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.31 | tnRmdIfDdmExtCalRxPower1 | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.32 | tnRmdIfDdmExtCalRxPower0 | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.33 | tnRmdIfDdmExtCalTxLaserBiasSlope | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.34 | tnRmdIfDdmExtCalTxLaserBiasOffset | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.35 | tnRmdIfDdmExtCalTxPowerSlope | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.36 | tnRmdIfDdmExtCalTxPowerOffset | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.38 | tnRmdIfDdmExtCalTemperatureOffset | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.39 | tnRmdIfDdmExtCalVoltageSlope | 0 | 0 | |
| 1.3.6.1.4.1.7483.6.4.1.3.7.1.40 | tnRmdIfDdmExtCalVoltageOffset | 0 | 0 |