Status in source: unspecified.
Names: sBladeVoltageLowerTrap
Technical details
{
"smi_kind": "TRAP-TYPE",
"definition": [
"sBladeVoltageLowerTrap",
"TRAP-TYPE",
"ENTERPRISE",
"egenera",
"VARIABLES",
"{",
"sBladeIndex",
",",
"sBladeFrameIndex",
",",
"sBladeName",
",",
"sensorName",
",",
"sensorThreshold",
",",
"sensorValue",
",",
"egeneraTrapSeverity",
",",
"egeneraTrapMessage",
"}",
"DESCRIPTION",
"\"Encapsulates sBlade critical low voltage sensor events. This trap is driven by 'Blade <framename>/s<1|2> <voltage-sensor-name> Critical Low Event' event types. The sensorValue and sensorThreshold fields are ingeter representations of real numbers. The real numbers are multiplied by 100 and rounded to produce an integer, thus 0.530 => 53. This trap replaces sBladeHwThreshTrap. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 3\"",
"::=",
"312"
],
"syntax_tree": [
[
"objectIdentifier",
[
"egenera"
]
],
[
"VarTypes",
[
"sBladeIndex",
"sBladeFrameIndex",
"sBladeName",
"sensorName",
"sensorThreshold",
"sensorValue",
"egeneraTrapSeverity",
"egeneraTrapMessage"
]
],
[
"DESCRIPTION",
"Encapsulates sBlade critical low voltage sensor events. This trap is driven by 'Blade <framename>/s<1|2> <voltage-sensor-name> Critical Low Event' event types. The sensorValue and sensorThreshold fields are ingeter representations of real numbers. The real numbers are multiplied by 100 and rounded to produce an integer, thus 0.530 => 53. This trap replaces sBladeHwThreshTrap. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 3"
],
null
]
}