The pBladeIndex value of the pServer's configured failover pBlade. -1 indicates none, -2 indicates global or local pool.
Sources for this description
Egenera BladeFrame MIB in the Fujitsu ServerView package
OID reference
1.3.6.1.4.1.7559.1.4.3.1.1.28
The pBladeIndex value of the pServer's configured failover pBlade. -1 indicates none, -2 indicates global or local pool.
Identification
{1 3 6 1 4 1 7559 1 4 3 1 1 28}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In EGENERA-MIB, the row index consists of these components in order:
lPanIndex (INTEGER): one numeric subidentifier for the non-negative value.pServerIndex (INTEGER): one numeric subidentifier for the non-negative value.An instance has the form .1.3.6.1.4.1.7559.1.4.3.1.1.28.<lPanIndex>.<pServerIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.7559.1.4.3.1.1.28
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
pServerFailoverPBladeIndex OBJECT-TYPE
SYNTAX INTEGER (-2..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The pBladeIndex value of the pServer's configured failover pBlade.
-1 indicates none, -2 indicates global or local pool."
::= { pServerEntry 28 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The pBladeIndex value of the pServer's configured failover pBlade. -1 indicates none, -2 indicates global or local pool.
Egenera BladeFrame MIB in the Fujitsu ServerView package
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: pServerFailoverPBladeIndex
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pServerFailoverPBladeIndex",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"-",
"2",
".",
".",
"2147483647",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The pBladeIndex value of the pServer's configured failover pBlade. -1 indicates none, -2 indicates global or local pool.\"",
"::=",
"{",
"pServerEntry",
"28",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
-2,
2147483647
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The pBladeIndex value of the pServer's configured failover pBlade. -1 indicates none, -2 indicates global or local pool."
],
null,
null,
null,
null
]
}Module: EGENERA-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks', 'enterprises']}Source data warning: This Egenera BladeFrame MIB is distributed in Fujitsu ServerView. The source file states it was last updated on 2005-08-30; its applicability to a particular device or software version has not been independently confirmed.
· Download Egenera BladeFrame MIB — Fujitsu ServerView packageRelated source files and packages:
Registration