Failure to accept timer
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.7777.1.1.40
Failure to accept timer
Identification
{1 3 6 1 4 1 7777 1 1 40}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.7777.1.1.40.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
failure_to_accept_timer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Failure to accept timer"
::= { transferswitch 40 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Failure to accept timer
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: failure_to_accept_timer
Vendor MIB copy from the Observium Community archive.
Module: ASCO-QEM-72EE2
See published definition above
· Download ASCO-QEM-72EE2Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7777.1.1.1 | phase_shift_between_normal_and_emergency | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.2 | normal_frequency | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.3 | emergency_frequency | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.4 | main_on_normal | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.5 | main_on_emergency | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.6 | auxiliary_on_normal | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.7 | auxiliary_on_emergency | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.8 | normal_source_available | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.9 | emergency_source_available | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.10 | engine_exerciser_with_load_active | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.11 | external_f17_is_active | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.12 | normal_voltage_phase_AB | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.13 | normal_voltage_phase_BC | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.14 | normal_voltage_phase_CA | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.15 | normal_voltage_unbalance | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.18 | emergency_voltage_phase_CA | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.19 | nominal_voltage | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.20 | nominal_frequency | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.21 | normal_source_3phase_sensing | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.22 | transfer_switch_type | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.23 | transfer_switch_ampere_rating | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.24 | controller_software_version | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.25 | controller_software_date | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.26 | external_parameter_lock_is_active | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.27 | engine_running | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.28 | controller_state | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.29 | controller_status_state_data | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.30 | timer_bypass_feature_6B_status | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.31 | remote_transfer_feature_17_status | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.32 | load_shed_feature_30_status | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.33 | transfer_inhibit_to_emergency_feature_34B_status | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.34 | local_test_feature_5_status | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.35 | manual_transfer_to_emergency_feature_6ZE_status | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.36 | current_sensing | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.37 | phase_A_current | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.38 | phase_B_current | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.39 | phase_C_current | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.41 | normal_to_emergency_pretransfer_time_delay_feature_31_bypass_enabled | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.42 | emergency_to_normal_pretransfer_time_delay_feature_31_bypass_enabled | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.43 | commit_to_transfer_enabled | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.44 | bypass_DTTS_source_failure_enabled | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.45 | inphase_transfer_enabled | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.46 | inphase_monitor_for_load_shed_feature_30_enabled | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.47 | fail_accept_timer_enabled | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.48 | transfer_retransfer_time_delay_bypass_feature_6B_input_enabled | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.49 | remote_transfer_feature_17_input_enabled | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.50 | retransfer_to_normal_mode_selector_feature_6DL_input_enabled | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.51 | serial_remote_transfer_feature_17_enabled | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.52 | voltage_unbalance_enabled | 0 | 0 | |
| 1.3.6.1.4.1.7777.1.1.53 | current_sensing_module_present | 0 | 0 |