Reference record for OID 1.3.6.1.4.1.789.0.724
- Parent
- 1.3.6.1.4.1.789.0 (0, netapp0)
- Node code
- 724
- Node name
- volMoveCutoverDeferred
- Numeric OID
- 1.3.6.1.4.1.789.0.724
- URN notation
- urn:oid:1.3.6.1.4.1.789.0.724
- Type
- NOTIFICATION-TYPE
- ASN.1 notation
-
{1 3 6 1 4 1 789 0 724}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) netapp(789) netapp0(0) volMoveCutoverDeferred(724)}
- OID-IRI notation
- /1/3/6/1/4/1/789/0/724
- /ISO/Identified-Organization/6/1/4/1/789/0/724
- /ISO/3/6/1/4/1/789/0/724
- Named path variants
- /iso/identified-organization/dod/internet/private/enterprise/netapp/0/volMoveCutoverDeferred
- /iso/identified-organization/dod/internet/private/enterprise/netapp/netapp0/volMoveCutoverDeferred
- /iso/identified-organization/dod/internet/private/enterprises/netapp/0/volMoveCutoverDeferred
- /iso/identified-organization/dod/internet/private/enterprises/netapp/netapp0/volMoveCutoverDeferred
- /iso/identified-organization/dod/internet/private/ldap-enterprise/netapp/0/volMoveCutoverDeferred
- /iso/identified-organization/dod/internet/private/ldap-enterprise/netapp/netapp0/volMoveCutoverDeferred
- /iso/identified-organization/dod/internet/private/vendor-objects/netapp/0/volMoveCutoverDeferred
- /iso/identified-organization/dod/internet/private/vendor-objects/netapp/netapp0/volMoveCutoverDeferred
- /iso/org/dod/internet/private/enterprise/netapp/0/volMoveCutoverDeferred
- /iso/org/dod/internet/private/enterprise/netapp/netapp0/volMoveCutoverDeferred
- /iso/org/dod/internet/private/enterprises/netapp/0/volMoveCutoverDeferred
- /iso/org/dod/internet/private/enterprises/netapp/netapp0/volMoveCutoverDeferred
- /iso/org/dod/internet/private/ldap-enterprise/netapp/0/volMoveCutoverDeferred
- /iso/org/dod/internet/private/ldap-enterprise/netapp/netapp0/volMoveCutoverDeferred
- /iso/org/dod/internet/private/vendor-objects/netapp/0/volMoveCutoverDeferred
- /iso/org/dod/internet/private/vendor-objects/netapp/netapp0/volMoveCutoverDeferred
- Additional combinations skipped.
Descriptions
Descriptions may differ between sources. The primary description is shown first.
Primary description: OID Repository
OBJECTS {productTrapData, productSerialNum}
STATUS current
DESCRIPTION
"A volume move job cannot be completed because cutover phase
has been deferred."
View at oid-base.com
Alternative description: MIBdepot
has been deferred.
Parsed from file netapp_2_2_2.mib.txt
Company: netapp
Module: NETAPP-MIB
Source file: Download netapp.mib · Publisher's file
Copy from Netdisco; File: netapp/netapp.mib; 1.1 MiB
Vendor MIB copy from the Netdisco archive.
Related source files and packages:
- Netdisco archive revision metadata (not a manufacturer release date)File: repos/netdisco/netdisco-mibs/commits/master; 15,422 bytes
- Netdisco MIB distribution at the selected archive revision38.9 MiB
Source file: Download NETAPP-MIB · Publisher's file
Copy from LibreNMS; File: netapp/NETAPP-MIB; 1.1 MiB
Vendor MIB copy from the LibreNMS archive.
Related source files and packages:
- LibreNMS original distribution archiveFile: librenms/librenms/tar.gz/…; 80.2 MiB
- Observium Community original distribution archivePublisher Last-Modified: Tue, 05 May 2026 13:47:48 GMT; 127.4 MiB
- Archive revision metadata: librenms/librenms (JSON)File: repos/librenms/librenms/commits/master; 36,945 bytes
Other archive copies with the same file
Source file: Download netapp_2_2_2.mib.txt
File: netapp/netapp_2_2_2.mib.txt; 1.0 MiB
Information from MIBdepot
volMoveCutoverDeferred NOTIFICATION-TYPE
OBJECTS {productTrapData, productSerialNum}
STATUS current
DESCRIPTION
"A volume move job cannot be completed because cutover phase
has been deferred."
::= { netapp 0 724 }
First Registration Authority (inferred from ancestor 1.3.6.1.4.1.789)
Siblings (258)
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.789.0.2 | userDefined | 0 | 0 | A polling-style trap built using the 'snmp traps' command on the filer. |
| 1.3.6.1.4.1.789.0.6 | dhmNoticeDegradedIO | 0 | 0 | Disk Health Monitor - Reported a Disk Degraded-I/O Event |
| 1.3.6.1.4.1.789.0.7 | dhmNoticePFAEvent | 0 | 0 | Disk Health Monitor - Reported a Disk Predictive-Failure Event |
| 1.3.6.1.4.1.789.0.11 | emergencyTrap | 0 | 0 | A user-defined trap indicating an extremely urgent situation, usually indicating that the system has failed and is shutting down. |
| 1.3.6.1.4.1.789.0.12 | alertTrap | 0 | 0 | A user-defined trap indicating a condition that should be corrected immediately, such as a failed disk. |
| 1.3.6.1.4.1.789.0.13 | criticalTrap | 0 | 0 | A user-defined trap indicating a critical condition, such as a hard device error. |
| 1.3.6.1.4.1.789.0.14 | errorTrap | 0 | 0 | A user-defined trap indicating an error condition, such as a mistake in a configuration file. |
| 1.3.6.1.4.1.789.0.15 | warningTrap | 0 | 0 | A user-defined trap indicating a condition which is not an error, but which may require special handling. |
| 1.3.6.1.4.1.789.0.16 | notificationTrap | 0 | 0 | A user-defined trap meant to provide notification, such as an hourly uptime message. |
| 1.3.6.1.4.1.789.0.17 | informationalTrap, debugTrap | 0 | 0 | A user-defined trap used for informational purposes. |
| 1.3.6.1.4.1.789.0.18 | dbgTrap | 0 | 0 | A user-defined trap used for debugging purposes. This trap was previously mis-documented as being trap number 17, with the name d… |
| 1.3.6.1.4.1.789.0.21 | diskFailedShutdown | 0 | 0 | System is shutting down because the system has been running in degraded mode for 24 hours. The trap includes a string describing … |
| 1.3.6.1.4.1.789.0.22 | diskFailed | 0 | 0 | One or more disks failed. The trap includes a string describing the failed disk(s). |
| 1.3.6.1.4.1.789.0.26 | diskRepaired | 0 | 0 | The failed disks have been repaired. This trap is a placeholder - it is not currently sent by Data ONTAP. |
| 1.3.6.1.4.1.789.0.31 | fanFailureShutdown | 0 | 0 | Critical chassis or cpu fans have failed and the system is shutting down. |
| 1.3.6.1.4.1.789.0.33 | fanFailed | 0 | 0 | One or more chassis fans failed. The trap includes a string describing the failed fan(s). |
| 1.3.6.1.4.1.789.0.35 | fanWarning | 0 | 0 | One or more chassis or cpu fans are in warning state. The trap includes a string describing the fan(s) in the warning state. |
| 1.3.6.1.4.1.789.0.36 | fanRepaired | 0 | 0 | All fans are repaired. |
| 1.3.6.1.4.1.789.0.41 | powerSupplyFailureShutdown | 0 | 0 | Critical power supplies or power rails failed and the system is shutting down. |
| 1.3.6.1.4.1.789.0.43 | powerSupplyFailed | 0 | 0 | One or more redundant power supplies failed. Include in the trap a string describing the failed power supply(ies). |
| 1.3.6.1.4.1.789.0.45 | powerSupplyWarning | 0 | 0 | One or more power supplies or power rails in warning state. Include in the trap a string describing the power supply(ies) or the… |
| 1.3.6.1.4.1.789.0.46 | powerSupplyRepaired | 0 | 0 | Previously-failed power supplies or power rails have been repaired. |
| 1.3.6.1.4.1.789.0.55 | cpuTooBusy | 0 | 0 | CPU utilization exceeds 90%. This trap is not enabled by default. To enable this trap set the registry entry options.monitor.cpu.e… |
| 1.3.6.1.4.1.789.0.56 | cpuOk | 0 | 0 | CPU utilization has dropped back below 90%. This trap is a placeholder - it is not currently sent by Data ONTAP. |
| 1.3.6.1.4.1.789.0.62 | nvramBatteryDischarged | 0 | 0 | The NVRAM battery is fully discharged. |
| 1.3.6.1.4.1.789.0.63 | nvramBatteryLow | 0 | 0 | The charge in the NVRAM battery is low. |
| 1.3.6.1.4.1.789.0.72 | clusterNodeFailed | 0 | 0 | A node in a Cluster FailOver configuration failed. Its partner will assume service for the failed node. |
| 1.3.6.1.4.1.789.0.75 | clusterNodeTakenOver | 0 | 0 | The partner has taken over for a failed cluster node. |
| 1.3.6.1.4.1.789.0.76 | clusterNodeRepaired | 0 | 0 | A cluster node has resumed operation. |
| 1.3.6.1.4.1.789.0.77 | clusterNodeRepairing | 0 | 0 | clusterNodeRepairing NOTIFICATION-TYPE OBJECTS {productTrapData, productSerialNum} STATUS current DESCRIPTION "A cluster node h… |
| 1.3.6.1.4.1.789.0.82 | volumeFull | 0 | 0 | At least one volume is more than 98% full. The string sent with the trap gives the name of the volume or volumes which exceed the … |
| 1.3.6.1.4.1.789.0.85 | volumeNearlyFull | 0 | 0 | At least one volume is more than 95% full. The string sent with the trap gives the name of the volume or volumes which exceed the … |
| 1.3.6.1.4.1.789.0.86 | volumeRepaired | 0 | 0 | All volumes are now under 95% full. |
| 1.3.6.1.4.1.789.0.87 | volumesStillFull | 0 | 0 | At least one volume that was full or nearly full is now OK, but more volumes still exceed the volumeNearlyFull or volumeFull thre… |
| 1.3.6.1.4.1.789.0.91 | overTempShutdown | 0 | 0 | System temperature is too high to continue operating. The system is shutting down. |
| 1.3.6.1.4.1.789.0.95 | overTemp | 0 | 0 | System temperature is too high and in the warning level. |
| 1.3.6.1.4.1.789.0.96 | overTempRepaired | 0 | 0 | System temperature has returned to an acceptable value. |
| 1.3.6.1.4.1.789.0.103 | shelfFault | 0 | 0 | A disk storage shelf reported a fault, probably due to a problem with drive placement, fans, power, or temperature. |
| 1.3.6.1.4.1.789.0.105 | shelfWarning | 0 | 0 | |
| 1.3.6.1.4.1.789.0.106 | shelfRepaired | 0 | 0 | A previously-reported shelf fault is now corrected. |
| 1.3.6.1.4.1.789.0.111 | globalStatusNonRecoverable | 0 | 0 | The appliance's overall status changed to 'nonRecoverable', indicating a problem so severe that the appliance is shutting down. |
| 1.3.6.1.4.1.789.0.113 | globalStatusCritical | 0 | 0 | The appliance's overall status changed to 'critical', indicating a problem that needs immediate attention. |
| 1.3.6.1.4.1.789.0.115 | globalStatusNonCritical | 0 | 0 | The appliance's overall status changed to 'nonCritical', indicating a problem that needs attention. |
| 1.3.6.1.4.1.789.0.116 | globalStatusOk | 0 | 0 | The appliance's overall status returned to normal. |
| 1.3.6.1.4.1.789.0.126 | softQuotaExceeded | 0 | 0 | A user has exceeded their soft quota limit. |
| 1.3.6.1.4.1.789.0.127 | softQuotaNormal | 0 | 0 | A user is safely back under their soft quota limit. |
| 1.3.6.1.4.1.789.0.134 | autosupportSendError | 0 | 0 | Unable to send autosupport. The trap includes a string describing the reason for the failure. |
| 1.3.6.1.4.1.789.0.135 | autosupportConfigurationError | 0 | 0 | Autosupport may be configured incorrectly. The trap includes a string describing the mis-configuration. |
| 1.3.6.1.4.1.789.0.136 | autosupportSent | 0 | 0 | Autosupport was sent successfully. |
| 1.3.6.1.4.1.789.0.142 | upsLinePowerOff | 0 | 0 | UPS: Input line power has failed and UPS is now on battery. |